Spread of bidet toilet flushing-generated infectious aerosols in the cubicle of a public restroom

IF 7.6 1区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY Building and Environment Pub Date : 2025-05-01 Epub Date: 2025-03-09 DOI:10.1016/j.buildenv.2025.112844
Yuanyuan Niu, Xiaohong Zheng, Jiayu Huang, Chenxue Song, Danting Luo, Haoren Qiu, Yongsheng Zhou, Hua Qian
{"title":"Spread of bidet toilet flushing-generated infectious aerosols in the cubicle of a public restroom","authors":"Yuanyuan Niu,&nbsp;Xiaohong Zheng,&nbsp;Jiayu Huang,&nbsp;Chenxue Song,&nbsp;Danting Luo,&nbsp;Haoren Qiu,&nbsp;Yongsheng Zhou,&nbsp;Hua Qian","doi":"10.1016/j.buildenv.2025.112844","DOIUrl":null,"url":null,"abstract":"<div><div>In public restrooms cubicles, flushing bidet toilets can generate infectious aerosols, potentially spreading of bacteria, viruses, and other pathogens. This study examines aerosol dispersion during bidet toilet flushing with the lid open and closed. Fluorescein sodium, simulating fecal matter, was seeded into the bidet toilet before flushing. Fluorescence intensity on surfaces, including the flush button, toilet lid, floor, walls, and breathing zone, was monitored, while aerosol concentrations (PM<sub>2.5</sub> and PM<sub>10</sub>) were measured by TSI dusttrak. Due to the limitations of aerosol sampling instruments, fluorescein sodium was used as a tracer to provide more cumulative and representative data. Results showed that aerosol deposition was significantly higher with the lid open, with total surface deposition 2.27 times greater than when closed. It is recommended to flush toilets with lids closed. If the lid must be opened, users should avoid touching the flush button and back right of the lid directly. When the previous user closes the toilet lid to flush, the next user should avoid touching the front right of the lid. With the lid open, the deposition of aerosols in the breathing zone decreased by 80.99% (log reduction = 0.72) at the 2nd minute compared to the peak in the 1st minute after flushing. Users are recommended to wait for 2 min after the early flush before entering bidet toilet cubicles. When covering the toilet lid, there was no significant aerosol deposition in the breathing zone. This further highlights the importance of flushing with the lid closed.</div></div>","PeriodicalId":9273,"journal":{"name":"Building and Environment","volume":"275 ","pages":"Article 112844"},"PeriodicalIF":7.6000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building and Environment","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360132325003269","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

In public restrooms cubicles, flushing bidet toilets can generate infectious aerosols, potentially spreading of bacteria, viruses, and other pathogens. This study examines aerosol dispersion during bidet toilet flushing with the lid open and closed. Fluorescein sodium, simulating fecal matter, was seeded into the bidet toilet before flushing. Fluorescence intensity on surfaces, including the flush button, toilet lid, floor, walls, and breathing zone, was monitored, while aerosol concentrations (PM2.5 and PM10) were measured by TSI dusttrak. Due to the limitations of aerosol sampling instruments, fluorescein sodium was used as a tracer to provide more cumulative and representative data. Results showed that aerosol deposition was significantly higher with the lid open, with total surface deposition 2.27 times greater than when closed. It is recommended to flush toilets with lids closed. If the lid must be opened, users should avoid touching the flush button and back right of the lid directly. When the previous user closes the toilet lid to flush, the next user should avoid touching the front right of the lid. With the lid open, the deposition of aerosols in the breathing zone decreased by 80.99% (log reduction = 0.72) at the 2nd minute compared to the peak in the 1st minute after flushing. Users are recommended to wait for 2 min after the early flush before entering bidet toilet cubicles. When covering the toilet lid, there was no significant aerosol deposition in the breathing zone. This further highlights the importance of flushing with the lid closed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
公共厕所隔间内坐浴盆冲水产生的传染性气溶胶的传播
在公共厕所的隔间里,抽水马桶会产生传染性气溶胶,潜在地传播细菌、病毒和其他病原体。本研究考察了在开盖和关盖的情况下冲坐浴盆时气溶胶的分散情况。在冲水之前,将模拟粪便物质的荧光素钠注入坐浴盆马桶。研究人员监测了冲洗按钮、马桶盖、地板、墙壁和呼吸区等表面的荧光强度,同时通过TSI粉尘追踪仪测量了气溶胶浓度(PM2.5和PM10)。由于气溶胶采样仪器的局限性,荧光素钠被用作示踪剂,以提供更多的累积和代表性的数据。结果表明,打开盖子时气溶胶沉降量显著增加,表面总沉降量是关闭盖子时的2.27倍。建议在冲厕时关闭马桶盖。如果必须打开盖子,用户应避免直接触摸冲洗按钮和盖子的右侧。当上一位使用者关上马桶盖冲水时,下一位使用者应避免触摸马桶盖的右前方。当盖子打开时,与冲洗后1分钟的峰值相比,呼吸区气溶胶沉积在第2分钟减少了80.99%(对数减少= 0.72)。建议用户在早期冲水后等待2分钟后再进入坐浴盆厕所隔间。盖上马桶盖后,呼吸区没有明显的气溶胶沉积。这进一步强调了关闭盖子冲洗的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Building and Environment
Building and Environment 工程技术-工程:环境
CiteScore
12.50
自引率
23.00%
发文量
1130
审稿时长
27 days
期刊介绍: Building and Environment, an international journal, is dedicated to publishing original research papers, comprehensive review articles, editorials, and short communications in the fields of building science, urban physics, and human interaction with the indoor and outdoor built environment. The journal emphasizes innovative technologies and knowledge verified through measurement and analysis. It covers environmental performance across various spatial scales, from cities and communities to buildings and systems, fostering collaborative, multi-disciplinary research with broader significance.
期刊最新文献
A Kriging-Markov hybrid method for real-time spatiotemporal indoor daylight prediction under data-sparse and sensor-limited conditions toward adaptive daylight control applications Temporal myopia in building Life Cycle Assessment? Granular versus coarse dynamics in climate change and grid decarbonisation A novel compatible fluid connector for liquid cooling system in data center BIM-based wind-driven rain modelling using ISO 15927-3 and geometry-based exposure Ten questions concerning participant engagement in building energy research
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1