The Effect of Different pH and Temperature Values on Ca2+, F-, PO43-, OH-, Si, and Sr2+ Release from Different Bioactive Restorative Dental Materials: An In Vitro Study.

IF 4.9 3区 工程技术 Q1 POLYMER SCIENCE Polymers Pub Date : 2025-02-27 DOI:10.3390/polym17050640
Angelo Aliberti, Fabiana Di Duca, Maria Triassi, Paolo Montuori, Stefano Scippa, Mirko Piscopo, Pietro Ausiello
{"title":"The Effect of Different pH and Temperature Values on Ca<sup>2+</sup>, F<sup>-</sup>, PO<sub>4</sub><sup>3-</sup>, OH<sup>-</sup>, Si, and Sr<sup>2+</sup> Release from Different Bioactive Restorative Dental Materials: An In Vitro Study.","authors":"Angelo Aliberti, Fabiana Di Duca, Maria Triassi, Paolo Montuori, Stefano Scippa, Mirko Piscopo, Pietro Ausiello","doi":"10.3390/polym17050640","DOIUrl":null,"url":null,"abstract":"<p><p>Bioactive restorative materials are crucial for promoting remineralization and protecting dental tissues through ion release. This study examines how pH and temperature influence the short- and long-term ion (F<sup>-</sup>, Ca<sup>2+</sup>, Sr<sup>2+</sup>, OH<sup>-</sup>, Si, and PO<sub>4</sub><sup>3-</sup>) release from seven commercial materials: <i>Cention Forte Filling Material</i>, <i>Cention Primer</i>, <i>Stela Self Cure</i>, <i>Riva Light Cure HV</i>, <i>Riva Self Cure</i>, <i>Equia Forte HT Fil</i>, and <i>Fuji IX GP Fast</i>. Disks were prepared according to the manufacturers' instructions; immersed in buffer solutions at pH 4.8, 6.8, and 8.8; and stored at 37 °C and 44 °C. Ion release was measured after 1, 7, and 28 days using ion chromatography and mass spectrometry. Results revealed that ion release was significantly affected by pH, temperature, and exposure time. The highest fluoride (40.14 ± 0.32 mg/L) and calcium (74.23 ± 0.37 mg/L) releases were observed in <i>Riva Light Cure</i> at pH 4.8 and 44 °C after 28 days, with the highest strontium release (5.87 ± 0.06 mg/L) occurring under the same conditions. In contrast, silicon release peaked in <i>Cention Forte Filling</i> (31.72 ± 0.68 mg/L) at pH 4.8 and 37 °C. These findings highlight the impact of environmental factors on material performance, assisting clinicians in selecting optimal restorative materials for long-term dental health.</p>","PeriodicalId":20416,"journal":{"name":"Polymers","volume":"17 5","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11902544/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polymers","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/polym17050640","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"POLYMER SCIENCE","Score":null,"Total":0}
引用次数: 0

Abstract

Bioactive restorative materials are crucial for promoting remineralization and protecting dental tissues through ion release. This study examines how pH and temperature influence the short- and long-term ion (F-, Ca2+, Sr2+, OH-, Si, and PO43-) release from seven commercial materials: Cention Forte Filling Material, Cention Primer, Stela Self Cure, Riva Light Cure HV, Riva Self Cure, Equia Forte HT Fil, and Fuji IX GP Fast. Disks were prepared according to the manufacturers' instructions; immersed in buffer solutions at pH 4.8, 6.8, and 8.8; and stored at 37 °C and 44 °C. Ion release was measured after 1, 7, and 28 days using ion chromatography and mass spectrometry. Results revealed that ion release was significantly affected by pH, temperature, and exposure time. The highest fluoride (40.14 ± 0.32 mg/L) and calcium (74.23 ± 0.37 mg/L) releases were observed in Riva Light Cure at pH 4.8 and 44 °C after 28 days, with the highest strontium release (5.87 ± 0.06 mg/L) occurring under the same conditions. In contrast, silicon release peaked in Cention Forte Filling (31.72 ± 0.68 mg/L) at pH 4.8 and 37 °C. These findings highlight the impact of environmental factors on material performance, assisting clinicians in selecting optimal restorative materials for long-term dental health.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同 pH 值和温度值对不同生物活性牙齿修复材料中 Ca2+、F-、PO43-、OH-、Si 和 Sr2+ 释放的影响:体外研究。
生物活性修复材料是促进再矿化和通过离子释放保护牙组织的关键。本研究考察了pH和温度如何影响七种商业材料(Cention Forte填充材料、Cention Primer、Stela Self Cure、Riva Light Cure HV、Riva Self Cure、Equia Forte HT Fil和Fuji IX GP Fast)的短期和长期离子(F-、Ca2+、Sr2+、OH-、Si和PO43-)释放。磁盘是根据制造商的说明制备的;浸泡在pH为4.8、6.8和8.8的缓冲液中;分别保存在37℃和44℃。用离子色谱和质谱法测定1、7和28天后的离子释放。结果表明,pH、温度和暴露时间对离子释放有显著影响。在pH值为4.8、温度为44°C的条件下,Riva光固化28天后,氟(40.14±0.32 mg/L)和钙(74.23±0.37 mg/L)的释放量最高,锶(5.87±0.06 mg/L)的释放量最高。在pH值为4.8、温度为37°C的条件下,Cention Forte填料的硅释放量达到最大值(31.72±0.68 mg/L)。这些发现强调了环境因素对材料性能的影响,帮助临床医生选择最佳的修复材料,以长期牙齿健康。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Polymers
Polymers POLYMER SCIENCE-
CiteScore
8.00
自引率
16.00%
发文量
4697
审稿时长
1.3 months
期刊介绍: Polymers (ISSN 2073-4360) is an international, open access journal of polymer science. It publishes research papers, short communications and review papers. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. Therefore, there is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Polymers provides an interdisciplinary forum for publishing papers which advance the fields of (i) polymerization methods, (ii) theory, simulation, and modeling, (iii) understanding of new physical phenomena, (iv) advances in characterization techniques, and (v) harnessing of self-assembly and biological strategies for producing complex multifunctional structures.
期刊最新文献
Differentiated Stem Cell-Seeded Gelatin/PLA/P(3HB-co-4HB) Meniscal Scaffold with Biocompatibility and Mechanical Strength. Tracking Solar Optimization in Renewable Energy Systems by Using Multiplexed Holograms in Bayfol® Photopolymers. Dynamics of Drone Blades Based on Polymer Nanocomposites Incorporating Graphene, Carbon Nanotube, and Fullerene. Microstructure and Mechanical Performance of 3D-Printed Carbon Fibre-PLA-PHA Composites. Experimental Study on the Influence of Ultraviolet Aging on the Shear Characteristics of HDPE Geomembrane/Sand Interface.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1