E Bismuth , M Joubert , E Renard , N Tubiana-Rufi , L Chaillous , E Bonnemaison , H Hanaire , R Coutant , P Schaepelynck , J Beltrand , Y Reznik , F Authier , S Borot , S Brunot , C Calvez , G Charpentier , F Dalla-Vale , A Delawoevre , B Delemer , A Desserprix , PY Benhamou
{"title":"Practical implementation of automated insulin delivery systems in 2025: A French position statement update","authors":"E Bismuth , M Joubert , E Renard , N Tubiana-Rufi , L Chaillous , E Bonnemaison , H Hanaire , R Coutant , P Schaepelynck , J Beltrand , Y Reznik , F Authier , S Borot , S Brunot , C Calvez , G Charpentier , F Dalla-Vale , A Delawoevre , B Delemer , A Desserprix , PY Benhamou","doi":"10.1016/j.diabet.2025.101637","DOIUrl":null,"url":null,"abstract":"<div><div>The advent of automated insulin delivery (AID) systems in 2020 marked a disruptive event in managing type 1 diabetes, benefiting children and adults alike. By 2024, advances in real-world data and research motivated an update to the French consensus on AID systems to expand accessibility, refine guidelines, and optimize patient follow-up.</div><div>AID systems have consistently improved glycemic control by reducing HbA1c, increasing time-in-range (TIR), and minimizing hypoglycemia, with significant benefits even for specific populations such as individuals with poor glycemic control, brittle diabetes, children, very young children, pregnant women, those with insulin resistance or gastroparesis, or after bariatric surgery. Recent studies support the broadening of AID indications for these special situations, also demonstrating safe transitions directly from multiple daily injections. A careful selection of the most appropriate system for these special situations is essential to achieve optimal personalization for each patient.</div><div>Training healthcare professionals and patients remains essential for optimizing AID usage. Updated guidelines emphasize multidisciplinary education, telemonitoring, and individualized follow-up to ensure safety and efficacy.</div><div>The potential of fully automated systems and adjunctive therapies, such as GLP-1 receptor agonists, is being explored alongside promising evidence that AID systems improve glycemic control in type 2 diabetes without increasing hypoglycemia. The future of AID systems lies in innovation and expanding their applicability across diverse patient populations.</div></div>","PeriodicalId":11334,"journal":{"name":"Diabetes & metabolism","volume":"51 3","pages":"Article 101637"},"PeriodicalIF":4.6000,"publicationDate":"2025-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes & metabolism","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1262363625000321","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
The advent of automated insulin delivery (AID) systems in 2020 marked a disruptive event in managing type 1 diabetes, benefiting children and adults alike. By 2024, advances in real-world data and research motivated an update to the French consensus on AID systems to expand accessibility, refine guidelines, and optimize patient follow-up.
AID systems have consistently improved glycemic control by reducing HbA1c, increasing time-in-range (TIR), and minimizing hypoglycemia, with significant benefits even for specific populations such as individuals with poor glycemic control, brittle diabetes, children, very young children, pregnant women, those with insulin resistance or gastroparesis, or after bariatric surgery. Recent studies support the broadening of AID indications for these special situations, also demonstrating safe transitions directly from multiple daily injections. A careful selection of the most appropriate system for these special situations is essential to achieve optimal personalization for each patient.
Training healthcare professionals and patients remains essential for optimizing AID usage. Updated guidelines emphasize multidisciplinary education, telemonitoring, and individualized follow-up to ensure safety and efficacy.
The potential of fully automated systems and adjunctive therapies, such as GLP-1 receptor agonists, is being explored alongside promising evidence that AID systems improve glycemic control in type 2 diabetes without increasing hypoglycemia. The future of AID systems lies in innovation and expanding their applicability across diverse patient populations.
期刊介绍:
A high quality scientific journal with an international readership
Official publication of the SFD, Diabetes & Metabolism, publishes high-quality papers by leading teams, forming a close link between hospital and research units. Diabetes & Metabolism is published in English language and is indexed in all major databases with its impact factor constantly progressing.
Diabetes & Metabolism contains original articles, short reports and comprehensive reviews.