Using Approximate Bayesian Computation to Calibrate the Model Parameters Characterizing the Autoregulatory Behavior of Microvessels

IF 2.2 4区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal for Numerical Methods in Biomedical Engineering Pub Date : 2025-03-17 DOI:10.1002/cnm.70023
Ali Daher
{"title":"Using Approximate Bayesian Computation to Calibrate the Model Parameters Characterizing the Autoregulatory Behavior of Microvessels","authors":"Ali Daher","doi":"10.1002/cnm.70023","DOIUrl":null,"url":null,"abstract":"<p>This study aims to leverage available experimental data on the myogenic and endothelial responses of the microvessels to calibrate the parameters and refine the functional form of the compliance feedback model. The experimental data used in this study trace the changes in the vessel calibre of individual arteriolar vessels in response to changes in the intraluminal pressure and/or the pressure gradient, which correspond to the myogenic and endothelial mechanisms, respectively. The compliance feedback model was previously developed to characterize the elastic and autoregulatory behavior of microvessels. We devise and employ a two-stage sequential Monte Carlo (MC) approximate Bayesian computation (ABC) scheme to obtain the posterior distribution of the model's parameters, such that the final parameter space distribution integrates information from any prior knowledge of the parameters, the model dynamics, and the available experimental data. Furthermore, the calibration scheme provides key insights into the underlying mechanistic features of the dynamical system; namely, the ABC scheme reveals that there is a marked difference in the time constants between the myogenic-induced dilation and constriction. Overall, upon parameter calibration, the computationally low-cost compliance feedback model achieves very good agreement with the experimental measurements, despite limited data availability, demonstrating that the model provides a simple, compact, yet robust and physiologically grounded characterization of the autoregulatory response, all of which are essential attributes to increase the translatability of hemodynamic models into the clinical environment for future clinical applications.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"41 3","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cnm.70023","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.70023","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study aims to leverage available experimental data on the myogenic and endothelial responses of the microvessels to calibrate the parameters and refine the functional form of the compliance feedback model. The experimental data used in this study trace the changes in the vessel calibre of individual arteriolar vessels in response to changes in the intraluminal pressure and/or the pressure gradient, which correspond to the myogenic and endothelial mechanisms, respectively. The compliance feedback model was previously developed to characterize the elastic and autoregulatory behavior of microvessels. We devise and employ a two-stage sequential Monte Carlo (MC) approximate Bayesian computation (ABC) scheme to obtain the posterior distribution of the model's parameters, such that the final parameter space distribution integrates information from any prior knowledge of the parameters, the model dynamics, and the available experimental data. Furthermore, the calibration scheme provides key insights into the underlying mechanistic features of the dynamical system; namely, the ABC scheme reveals that there is a marked difference in the time constants between the myogenic-induced dilation and constriction. Overall, upon parameter calibration, the computationally low-cost compliance feedback model achieves very good agreement with the experimental measurements, despite limited data availability, demonstrating that the model provides a simple, compact, yet robust and physiologically grounded characterization of the autoregulatory response, all of which are essential attributes to increase the translatability of hemodynamic models into the clinical environment for future clinical applications.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
期刊最新文献
Machine Learning-Based Rapid Prediction of Torsional Performance of Personalized Peripheral Artery Stent Using Approximate Bayesian Computation to Calibrate the Model Parameters Characterizing the Autoregulatory Behavior of Microvessels Mechanobiological Model of Endochondral Ossification and Trabecular Bone Modeling Advancements in Coronary Bifurcation Stenting Techniques: Insights From Computational and Bench Testing Studies Prognosis of Crestally Placed Short Plateau Implants in Posterior Maxilla
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1