{"title":"Development of a Semi-automatic Finite Element Modeling Workflow for the Evaluation of Cranial Suture-Bone Complex Temporal Strain Evolution During Growth.","authors":"Tsolmonbaatar Khurelbaatar, Mahzad Sadati, Rachel Schultz, Leah Fisher, Emilie Robertson, Curtis Budden, Tracy Popowics, Michael R Doschak, Christopher R Dennison, Lindsey Westover, Dan L Romanyk","doi":"10.1007/s10439-025-03710-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to develop a semi-automatic workflow for medical image segmentation and finite element (FE) modeling. The workflow was subsequently used to investigate the temporal evolution of the localized mechanical strain in the rat coronal suture during normal growth.</p><p><strong>Methods: </strong>The subject-specific FE models were created based on in vivo longitudinal micro-computed tomography images acquired from n = 4 rats (AUP00003759, 11/04/2021). The FE models were created through a semi-automatic workflow that consisted of a semi-automatic segmentation of the rat cranial sutures, a simplified full skull model, and the detailed coronal suture model. Simulated intracranial pressure loading was implemented, and the localized equivalent, maximum principal, and minimum principal strains were estimated at volumes of interest (VOIs) selected along the suture-bone interface.</p><p><strong>Results: </strong>The semi-automatic segmentations were consistent among operators with a coefficient of variation of 1.8% and showed good agreement compared to the manual segmentation, with maximum differences of 4.1% and 2.0% in terms of suture volume and surface area, respectively. The estimated strains evolved with a trend increasing from 7 to 9 week and 9 to 11 week time intervals and decreasing from 11 to 16 week time interval for all VOIs. The results showed that strains at VOIs significantly changed (p < 0.05) over time. The concave regions of the suture experienced the highest magnitude of strains.</p><p><strong>Conclusion: </strong>The presented research has developed an appropriate semi-automatic FE workflow capable of evaluating temporal changes in mechanical strain of cranial sutures during growth, and was utilized to demonstrate transient and location-specific changes in the rat coronal suture.</p>","PeriodicalId":7986,"journal":{"name":"Annals of Biomedical Engineering","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10439-025-03710-5","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to develop a semi-automatic workflow for medical image segmentation and finite element (FE) modeling. The workflow was subsequently used to investigate the temporal evolution of the localized mechanical strain in the rat coronal suture during normal growth.

Methods: The subject-specific FE models were created based on in vivo longitudinal micro-computed tomography images acquired from n = 4 rats (AUP00003759, 11/04/2021). The FE models were created through a semi-automatic workflow that consisted of a semi-automatic segmentation of the rat cranial sutures, a simplified full skull model, and the detailed coronal suture model. Simulated intracranial pressure loading was implemented, and the localized equivalent, maximum principal, and minimum principal strains were estimated at volumes of interest (VOIs) selected along the suture-bone interface.

Results: The semi-automatic segmentations were consistent among operators with a coefficient of variation of 1.8% and showed good agreement compared to the manual segmentation, with maximum differences of 4.1% and 2.0% in terms of suture volume and surface area, respectively. The estimated strains evolved with a trend increasing from 7 to 9 week and 9 to 11 week time intervals and decreasing from 11 to 16 week time interval for all VOIs. The results showed that strains at VOIs significantly changed (p < 0.05) over time. The concave regions of the suture experienced the highest magnitude of strains.

Conclusion: The presented research has developed an appropriate semi-automatic FE workflow capable of evaluating temporal changes in mechanical strain of cranial sutures during growth, and was utilized to demonstrate transient and location-specific changes in the rat coronal suture.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Annals of Biomedical Engineering
Annals of Biomedical Engineering 工程技术-工程:生物医学
CiteScore
7.50
自引率
15.80%
发文量
212
审稿时长
3 months
期刊介绍: Annals of Biomedical Engineering is an official journal of the Biomedical Engineering Society, publishing original articles in the major fields of bioengineering and biomedical engineering. The Annals is an interdisciplinary and international journal with the aim to highlight integrated approaches to the solutions of biological and biomedical problems.
期刊最新文献
Development of a Semi-automatic Finite Element Modeling Workflow for the Evaluation of Cranial Suture-Bone Complex Temporal Strain Evolution During Growth. Muscles Functioning as Primary Shoulder Movers Aid the Rotator Cuff Muscles in Increasing Active Glenohumeral Stiffness. The I-PREDICT 50th Percentile Male Finite Element Model: Development and Validation of the Torso. Controlling Negative and Positive Power for Efficiency Enhancement and Muscle Strain Mitigation During Squatting with a Portable Knee Exoskeleton. Combined Rigid-Flexible Multibody Analysis Reveals Reduced Pedicle Screw Loads in Short-Segment Fixation for Decompressed Lumbar Spine Stabilization.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1