High-Accuracy Augmented Reality Guidance for Intracranial Drain Placement Using a Standalone Head-Worn Navigation System: First-in-Human Results.

IF 3.9 2区 医学 Q1 CLINICAL NEUROLOGY Neurosurgery Pub Date : 2025-06-01 Epub Date: 2025-03-20 DOI:10.1227/neu.0000000000003401
Frederick Van Gestel, Taylor Frantz, Félix Buyck, Anthony G Gallagher, Wietse Geens, Quentin Neuville, Michael Bruneau, Bart Jansen, Thierry Scheerlinck, Jef Vandemeulebroucke, Johnny Duerinck
{"title":"High-Accuracy Augmented Reality Guidance for Intracranial Drain Placement Using a Standalone Head-Worn Navigation System: First-in-Human Results.","authors":"Frederick Van Gestel, Taylor Frantz, Félix Buyck, Anthony G Gallagher, Wietse Geens, Quentin Neuville, Michael Bruneau, Bart Jansen, Thierry Scheerlinck, Jef Vandemeulebroucke, Johnny Duerinck","doi":"10.1227/neu.0000000000003401","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>External ventricular drain (EVD) placement is often performed freehand, a technique subpar to accurate yet impractical image-guided methods, yielding optimal placement in only 70%. The aim of this study was to address shortcomings in EVD placement and image guidance technologies by implementing high-accuracy augmented reality (AR) guidance.</p><p><strong>Methods: </strong>We conducted a prospective clinical pilot study to assess feasibility, safety, and clinical performance of EVD placement using a standalone AR headset equipped with high-accuracy inside-out infrared tracking and software addressing EVD placement. Placement quality was reported using a newly defined extended modified Kakarla scale, and dichotomized into clinically relevant outcome parameters. Results were compared with a nonconcurrent freehand control group using one-sided Fisher exact tests.</p><p><strong>Results: </strong>Eleven AR-guided EVD placements were performed, achieving functional placement in all cases on the first attempt, vs 7 (64%) in the control group ( P = .045); successful placement in 9 (82%) vs 5 (45%); optimal in 8 (73%) vs 3 (27%) ( P = .043); suboptimal in 2 (18%) vs 5 (45%); and failed in 0 vs 1 (9%). No AR-guided placements required revision, whereas the freehand group had a 36% reintervention rate ( P = .045). Procedure-related complications occurred in 2 AR-guided cases (18%), vs 5 (45%) freehand (all post-reintervention).</p><p><strong>Conclusion: </strong>This study presents the first clinical use case of EVD placement using high-accuracy AR guidance contained in a standalone head-worn navigation system. Safe and reliable outcomes using a validated pipeline were demonstrated, eliminating stick-and-poke attempts and resulting in improved quality, increased single attempt success rates, and reduced revision and complication rates. Based on these results, a multicenter randomized controlled trial will be initiated.</p>","PeriodicalId":19276,"journal":{"name":"Neurosurgery","volume":" ","pages":"1217-1226"},"PeriodicalIF":3.9000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12052230/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1227/neu.0000000000003401","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: External ventricular drain (EVD) placement is often performed freehand, a technique subpar to accurate yet impractical image-guided methods, yielding optimal placement in only 70%. The aim of this study was to address shortcomings in EVD placement and image guidance technologies by implementing high-accuracy augmented reality (AR) guidance.

Methods: We conducted a prospective clinical pilot study to assess feasibility, safety, and clinical performance of EVD placement using a standalone AR headset equipped with high-accuracy inside-out infrared tracking and software addressing EVD placement. Placement quality was reported using a newly defined extended modified Kakarla scale, and dichotomized into clinically relevant outcome parameters. Results were compared with a nonconcurrent freehand control group using one-sided Fisher exact tests.

Results: Eleven AR-guided EVD placements were performed, achieving functional placement in all cases on the first attempt, vs 7 (64%) in the control group ( P = .045); successful placement in 9 (82%) vs 5 (45%); optimal in 8 (73%) vs 3 (27%) ( P = .043); suboptimal in 2 (18%) vs 5 (45%); and failed in 0 vs 1 (9%). No AR-guided placements required revision, whereas the freehand group had a 36% reintervention rate ( P = .045). Procedure-related complications occurred in 2 AR-guided cases (18%), vs 5 (45%) freehand (all post-reintervention).

Conclusion: This study presents the first clinical use case of EVD placement using high-accuracy AR guidance contained in a standalone head-worn navigation system. Safe and reliable outcomes using a validated pipeline were demonstrated, eliminating stick-and-poke attempts and resulting in improved quality, increased single attempt success rates, and reduced revision and complication rates. Based on these results, a multicenter randomized controlled trial will be initiated.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高精度增强现实指导颅内引流放置使用独立的头戴式导航系统:首次在人类的结果。
背景和目的:体外脑室引流(EVD)的放置通常是徒手进行的,这是一种低于准确且不切实际的图像引导方法的技术,只有70%的位置是最佳的。本研究的目的是通过实现高精度增强现实(AR)制导来解决EVD放置和图像制导技术的缺点。方法:我们进行了一项前瞻性临床试点研究,以评估EVD放置的可行性、安全性和临床性能,使用配备高精度由内而外红外跟踪和定位EVD放置的软件的独立AR头显。使用新定义的扩展改良Kakarla量表报告放置质量,并将其分为临床相关结果参数。结果采用单侧Fisher精确检验与非并发徒手对照组进行比较。结果:进行了11例ar引导的EVD放置,所有病例在第一次尝试时都实现了功能放置,而对照组为7例(64%)(P = 0.045);9 (82%) vs 5 (45%);最佳为8 (73%)vs 3 (27%) (P = 0.043);2 (18%) vs 5(45%)次优;0比1(9%)失败。无ar引导放置需要修改,而徒手组有36%的再干预率(P = 0.045)。ar引导下2例(18%)发生手术相关并发症,徒手5例(45%)发生手术相关并发症(均为再干预后)。结论:本研究提出了首个使用独立头戴式导航系统中包含的高精度AR导航定位EVD的临床应用案例。使用经过验证的管道,证明了安全可靠的结果,消除了粘贴和戳的尝试,从而提高了质量,增加了单次尝试的成功率,减少了修改和并发症的发生率。基于这些结果,将启动一项多中心随机对照试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Neurosurgery
Neurosurgery 医学-临床神经学
CiteScore
8.20
自引率
6.20%
发文量
898
审稿时长
2-4 weeks
期刊介绍: Neurosurgery, the official journal of the Congress of Neurological Surgeons, publishes research on clinical and experimental neurosurgery covering the very latest developments in science, technology, and medicine. For professionals aware of the rapid pace of developments in the field, this journal is nothing short of indispensable as the most complete window on the contemporary field of neurosurgery. Neurosurgery is the fastest-growing journal in the field, with a worldwide reputation for reliable coverage delivered with a fresh and dynamic outlook.
期刊最新文献
Anatomic Predilection of Isocitrate Dehydrogenase-Mutant Gliomas: A Multi-Institutional Spatial Analysis. CEREBLEED: Automated Quantification and Severity Scoring of Intracranial Hemorrhage on Noncontrast CT. Posterior Facet Distraction and Fusion Technique: Driving a Paradigm Shift in the Surgical Algorithm for Atlantoaxial Dislocation. Clinical Characteristics and Long-Term Outcomes of Atypical Choroid Plexus Papillomas: A Single-Center Experience of 40 Cases. Commentary: Reoperation Risk Factors for Cranioplasty Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1