{"title":"Manufacturing and Testing HTS Coils for Magnetic Mirror","authors":"Grant Kristofek;Alexi Radovinsky;Alexander Zhukovsky;Nick Kelton;Sergey Kuznetsov;Robert Mumgaard;Jeremy Hollman;Nicoli Ames;P. Brandon Carroll;Jeff Howell;Ben Nottingham;Daniel Sullivan","doi":"10.1109/TASC.2025.3542351","DOIUrl":null,"url":null,"abstract":"Commonwealth Fusion Systems (CFS) completed the design, construction, assembly, and full field dual magnet factory acceptance testing of two identical compact (< 2 ton), high-field (20 T on tape, 17 T in warm bore) HTS REBCO magnets for a magnetic mirror in an axial fusion device. The CFS magnets will serve as the high field end coils for the ARPA-E funded project, “An HTS Axisymmetric Magnetic Mirror on a Faster Path to Lower Cost Fusion Energy.” CFS is a subrecipient of the ARPA-E BETHE Fusion Grant with the University of Wisconsin-Madison.The CFS magnets are DC magnets which will operate in the presence of other magnetic coils. The magnets use partial insulation pancake design. They are conduction cooled by cryocoolers to a nominal design operating temperature of 20 K. Field-induced mechanical stresses in the winding pack are managed such that the tape is constrained within allowable stress and strain during magnet operation. The winding pack is mechanically supported and thermally isolated in the cryostat by a set of high strength, low thermal conductivity supports. The cold mass supports are designed to sustain over 60 tons of axial loading during peak operating conditions. Results of the magnet tests and commissioning are presented below.","PeriodicalId":13104,"journal":{"name":"IEEE Transactions on Applied Superconductivity","volume":"35 5","pages":"1-5"},"PeriodicalIF":1.8000,"publicationDate":"2025-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Applied Superconductivity","FirstCategoryId":"101","ListUrlMain":"https://ieeexplore.ieee.org/document/10896470/","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Commonwealth Fusion Systems (CFS) completed the design, construction, assembly, and full field dual magnet factory acceptance testing of two identical compact (< 2 ton), high-field (20 T on tape, 17 T in warm bore) HTS REBCO magnets for a magnetic mirror in an axial fusion device. The CFS magnets will serve as the high field end coils for the ARPA-E funded project, “An HTS Axisymmetric Magnetic Mirror on a Faster Path to Lower Cost Fusion Energy.” CFS is a subrecipient of the ARPA-E BETHE Fusion Grant with the University of Wisconsin-Madison.The CFS magnets are DC magnets which will operate in the presence of other magnetic coils. The magnets use partial insulation pancake design. They are conduction cooled by cryocoolers to a nominal design operating temperature of 20 K. Field-induced mechanical stresses in the winding pack are managed such that the tape is constrained within allowable stress and strain during magnet operation. The winding pack is mechanically supported and thermally isolated in the cryostat by a set of high strength, low thermal conductivity supports. The cold mass supports are designed to sustain over 60 tons of axial loading during peak operating conditions. Results of the magnet tests and commissioning are presented below.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
磁镜用高温超导线圈的制造与测试
英联邦聚变系统公司(CFS)完成了用于轴向聚变装置磁镜的两个相同紧凑(< 2吨)、高磁场(20 T磁带,17 T温膛)HTS REBCO磁体的设计、建造、组装和全磁场双磁体工厂验收测试。CFS磁体将作为ARPA-E资助项目的高场端线圈,该项目名为“更快地实现低成本聚变能的高温超导轴对称磁镜”。CFS是ARPA-E BETHE融合基金与威斯康星大学麦迪逊分校的分接受者。CFS磁体是直流磁体,可在其他磁线圈存在的情况下运行。磁体采用部分绝缘的煎饼式设计。它们通过低温冷却器传导冷却到标称设计工作温度20k。在磁体运行过程中,缠绕组中的场致机械应力被控制在允许的应力和应变范围内。缠绕包由机械支撑,并在低温恒温器中通过一组高强度,低导热性的支撑进行热隔离。冷质量支撑设计为在峰值运行条件下承受超过60吨的轴向载荷。磁铁试验和调试的结果如下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Applied Superconductivity
IEEE Transactions on Applied Superconductivity 工程技术-工程:电子与电气
CiteScore
3.50
自引率
33.30%
发文量
650
审稿时长
2.3 months
期刊介绍: IEEE Transactions on Applied Superconductivity (TAS) contains articles on the applications of superconductivity and other relevant technology. Electronic applications include analog and digital circuits employing thin films and active devices such as Josephson junctions. Large scale applications include magnets for power applications such as motors and generators, for magnetic resonance, for accelerators, and cable applications such as power transmission.
期刊最新文献
Low-AC-Loss Nb3Sn Validation Model Coil in Solid Nitrogen for a Fast-Switching-Field MRI Magnet Prototype. Cooldown and Ramp Test of a Low-Cryogen, Lightweight, Head-Only 7T MRI Magnet. Front Cover Table of Contents IEEE Transactions on Applied Superconductivity Publication Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1