Magnetic solid-phase extraction of Sudan dyes from beverages-coated magnetite/silica materials

Yugao Guo , Xiaoxiao Niu , Boyu Li , Pei Liu , Youqing Sun , Sumin Lu
{"title":"Magnetic solid-phase extraction of Sudan dyes from beverages-coated magnetite/silica materials","authors":"Yugao Guo ,&nbsp;Xiaoxiao Niu ,&nbsp;Boyu Li ,&nbsp;Pei Liu ,&nbsp;Youqing Sun ,&nbsp;Sumin Lu","doi":"10.1016/j.jpbao.2025.100073","DOIUrl":null,"url":null,"abstract":"<div><div>In this study, a polydopamine-coated magnetite/silica composite material (Fe<sub>3</sub>O<sub>4</sub>@SiO<sub>2</sub>/PDA) was successfully synthesized and characterized using Fourier-transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). By integrating EM-MSPE with high-performance liquid chromatography (HPLC), a novel EM-MSPE-HPLC method was established for the sensitive and accurate determination of Sudan I-IV dyes. Key experimental parameters, such as adsorbent dosage, pH, inorganic salt concentration, adsorption time, voltage, eluent type, eluent volume, and desorption time, were systematically investigated and optimized. Under optimal conditions, the method demonstrated excellent linearity (R² &gt; 0.999) within a concentration range of 5–1000 μg L⁻¹, with limits of detection (LODs) ranging from 0.11 to 0.17 μg L⁻¹. The recoveries of Sudan dyes in real samples ranged from 89.1 % to 101.9 %, with relative standard deviations (RSDs) between 0.3 % and 3.6 %. Furthermore, the Fe<sub>3</sub>O<sub>4</sub>@SiO<sub>2</sub>/PDA adsorbent exhibited consistent performance over ten consecutive extraction cycles without significant loss in recovery efficiency. These findings demonstrate that the proposed method is accurate, reliable, and reproducible for the simultaneous determination of Sudan dyes in complex beverage matrices, offering a robust analytical approach for food safety applications.</div></div>","PeriodicalId":100822,"journal":{"name":"Journal of Pharmaceutical and Biomedical Analysis Open","volume":"5 ","pages":"Article 100073"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmaceutical and Biomedical Analysis Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949771X25000246","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, a polydopamine-coated magnetite/silica composite material (Fe3O4@SiO2/PDA) was successfully synthesized and characterized using Fourier-transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). By integrating EM-MSPE with high-performance liquid chromatography (HPLC), a novel EM-MSPE-HPLC method was established for the sensitive and accurate determination of Sudan I-IV dyes. Key experimental parameters, such as adsorbent dosage, pH, inorganic salt concentration, adsorption time, voltage, eluent type, eluent volume, and desorption time, were systematically investigated and optimized. Under optimal conditions, the method demonstrated excellent linearity (R² > 0.999) within a concentration range of 5–1000 μg L⁻¹, with limits of detection (LODs) ranging from 0.11 to 0.17 μg L⁻¹. The recoveries of Sudan dyes in real samples ranged from 89.1 % to 101.9 %, with relative standard deviations (RSDs) between 0.3 % and 3.6 %. Furthermore, the Fe3O4@SiO2/PDA adsorbent exhibited consistent performance over ten consecutive extraction cycles without significant loss in recovery efficiency. These findings demonstrate that the proposed method is accurate, reliable, and reproducible for the simultaneous determination of Sudan dyes in complex beverage matrices, offering a robust analytical approach for food safety applications.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
饮料包覆磁铁矿/二氧化硅材料中苏丹红染料的磁固相萃取
本研究成功合成了一种聚多巴胺包覆磁铁矿/二氧化硅复合材料(Fe3O4@SiO2/PDA),并利用傅里叶变换红外光谱(FT-IR)、x射线衍射(XRD)和x射线光电子能谱(XPS)对其进行了表征。将EM-MSPE与高效液相色谱(HPLC)相结合,建立了灵敏、准确测定苏丹红I-IV染料的EM-MSPE-HPLC新方法。对吸附剂用量、pH、无机盐浓度、吸附时间、电压、洗脱液类型、洗脱液体积、脱附时间等关键实验参数进行了系统的考察和优化。在最佳条件下,该方法具有良好的线性(R²>;0.999),浓度范围为5-1000 μg L -⁻¹,检测限(lod)范围为0.11至0.17 μg L -⁻¹。苏丹红染料在实际样品中的回收率为89.1 % ~ 101.9 %,相对标准偏差(rsd)为0.3 % ~ 3.6 %。此外,Fe3O4@SiO2/PDA吸附剂在连续10次萃取循环中表现出一致的性能,且回收率没有明显下降。这些结果表明,该方法准确、可靠、可重复性好,可用于复杂饮料基质中苏丹红染料的同时测定,为食品安全应用提供了可靠的分析方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Quantitative analysis of D/L-serine and D/L-proline in serum by isotope-coded derivatization using an original chiral resolution labeling reagent Investigation of the metabolic role of d-amino acid aminotransferase in Arabidopsis thaliana using a column-switching two-dimensional high-performance liquid chromatography system Microsampling for antidepressant drug analysis: Current state and perspectives A simple approach for amperometric determination of pyridoxine and caffeine in pre-workout supplements using batch injection analysis with boron-doped diamond electrode Biosensory implications of scaffolds: Designing, integration and biomedical applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1