Electrochemical detection of creatinine at picomolar scale with an extended linear dynamic range in human body fluids for diagnosis of kidney dysfunction

IF 6 2区 化学 Q1 CHEMISTRY, ANALYTICAL Analytica Chimica Acta Pub Date : 2025-03-27 DOI:10.1016/j.aca.2025.343978
Sanya Khursheed , Sumera Sarwar , Dilshad Hussain , Muhammad Raza Shah , Jiri Barek , Muhammad Imran Malik
{"title":"Electrochemical detection of creatinine at picomolar scale with an extended linear dynamic range in human body fluids for diagnosis of kidney dysfunction","authors":"Sanya Khursheed ,&nbsp;Sumera Sarwar ,&nbsp;Dilshad Hussain ,&nbsp;Muhammad Raza Shah ,&nbsp;Jiri Barek ,&nbsp;Muhammad Imran Malik","doi":"10.1016/j.aca.2025.343978","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Creatinine levels in different body fluids can serve as an important biomarker for kidney functioning relevant to prostate cancer and chronic kidney disease (CKD). Creatinine levels vary in concentration in different body fluids, such as blood, urine, and saliva. Unlike previously reported sensors, the developed creatinine sensor can be employed for all levels of creatinine in samples of real patients.</div></div><div><h3>Results</h3><div>In this study, an efficient voltammetric sensor for creatinine is developed by modifying a glassy carbon electrode (GCE) with poly (ethyleneimine) (PEI) capped silver nanoparticles at titanium dioxide (PEI-AgNPs)/TiO<sub>2</sub>, i.e., titanium dioxide (TiO<sub>2</sub>)/graphene oxide (GO) nanocomposites (Ag@GO/TiO<sub>2</sub>-GCE). The Ag@GO/TiO<sub>2</sub> nanocomposite was characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), thermal gravimetric analysis (TGA), X-ray diffraction (XRD), transmission electron microscopy (TEM), dynamic light scattering (DLS), zeta potential, Fourier transform infrared (FT-IR) spectroscopy, and UV–Vis spectrophotometry. Various voltammetric techniques namely cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), chronoamperometry (CA), and differential pulse voltammetry (DPV) were employed. The Ag@GO/TiO<sub>2</sub>-GCE demonstrated good selectivity, stability, and a quick response time of 1.0 s for creatinine. An extended linear dynamic range (LDR) of creatinine from 0.01 pM (DPV) to 1.0 M (CV) based on different voltammetric techniques is imperative for detecting diverse creatinine levels in various body fluids. The LOD and LOQ of the developed creatinine detection method were found to be 1.15 pM and 3.5 pM, respectively. The electrochemical sensor exhibited an exceptionally high sensitivity of 15.74 μApM<sup>−1</sup>cm<sup>−2</sup>.The body fluids from healthy volunteers were spiked with a known amount of creatinine to evaluate sensor efficiency in the context of recovery. Finally, blood serum, saliva, and urine samples of kidney patients were analyzed for creatinine levels.</div></div><div><h3>Significance</h3><div>An important merit of the developed creatinine sensor is its ability for non-invasive point-of-care diagnosis in saliva with more than 90 % recovery. The comparison of the developed method with the standard Jaffes' colorimetric method endorsed its reliability and extended ability for the samples where Jaffes’ method fails. The low LOD, high sensitivity, extended LDR, and low-cost render the possibility of adopting this method for point-of-care diagnosis.</div></div>","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":"1353 ","pages":"Article 343978"},"PeriodicalIF":6.0000,"publicationDate":"2025-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003267025003721","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Creatinine levels in different body fluids can serve as an important biomarker for kidney functioning relevant to prostate cancer and chronic kidney disease (CKD). Creatinine levels vary in concentration in different body fluids, such as blood, urine, and saliva. Unlike previously reported sensors, the developed creatinine sensor can be employed for all levels of creatinine in samples of real patients.

Results

In this study, an efficient voltammetric sensor for creatinine is developed by modifying a glassy carbon electrode (GCE) with poly (ethyleneimine) (PEI) capped silver nanoparticles at titanium dioxide (PEI-AgNPs)/TiO2, i.e., titanium dioxide (TiO2)/graphene oxide (GO) nanocomposites (Ag@GO/TiO2-GCE). The Ag@GO/TiO2 nanocomposite was characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), thermal gravimetric analysis (TGA), X-ray diffraction (XRD), transmission electron microscopy (TEM), dynamic light scattering (DLS), zeta potential, Fourier transform infrared (FT-IR) spectroscopy, and UV–Vis spectrophotometry. Various voltammetric techniques namely cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), chronoamperometry (CA), and differential pulse voltammetry (DPV) were employed. The Ag@GO/TiO2-GCE demonstrated good selectivity, stability, and a quick response time of 1.0 s for creatinine. An extended linear dynamic range (LDR) of creatinine from 0.01 pM (DPV) to 1.0 M (CV) based on different voltammetric techniques is imperative for detecting diverse creatinine levels in various body fluids. The LOD and LOQ of the developed creatinine detection method were found to be 1.15 pM and 3.5 pM, respectively. The electrochemical sensor exhibited an exceptionally high sensitivity of 15.74 μApM−1cm−2.The body fluids from healthy volunteers were spiked with a known amount of creatinine to evaluate sensor efficiency in the context of recovery. Finally, blood serum, saliva, and urine samples of kidney patients were analyzed for creatinine levels.

Significance

An important merit of the developed creatinine sensor is its ability for non-invasive point-of-care diagnosis in saliva with more than 90 % recovery. The comparison of the developed method with the standard Jaffes' colorimetric method endorsed its reliability and extended ability for the samples where Jaffes’ method fails. The low LOD, high sensitivity, extended LDR, and low-cost render the possibility of adopting this method for point-of-care diagnosis.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电化学检测体液中肌酸酐在皮摩尔尺度下的扩展线性动态范围用于诊断肾功能障碍
背景:不同体液中肌酐水平可以作为与前列腺癌和慢性肾脏疾病(CKD)相关的肾脏功能的重要生物标志物。肌酐水平在不同体液中的浓度不同,如血液、尿液和唾液。与以前报道的传感器不同,开发的肌酐传感器可以用于真实患者样品中的所有水平的肌酐。结果本研究通过在二氧化钛(PEI- agnps)/二氧化钛(TiO2),即二氧化钛(TiO2)/氧化石墨烯(GO)纳米复合材料(Ag@GO/TiO2-GCE)上涂覆纳米银修饰玻碳电极(GCE),开发了一种高效的肌酸酐伏安传感器。采用扫描电子显微镜(SEM)、原子力显微镜(AFM)、热重分析(TGA)、x射线衍射(XRD)、透射电子显微镜(TEM)、动态光散射(DLS)、zeta电位、傅里叶变换红外光谱(FT-IR)和紫外可见分光光度法对Ag@GO/TiO2纳米复合材料进行了表征。采用了循环伏安法(CV)、电化学阻抗法(EIS)、计时伏安法(CA)和差分脉冲伏安法(DPV)等多种伏安技术。Ag@GO/TiO2-GCE对肌酐具有良好的选择性和稳定性,反应时间为1.0 s。基于不同伏安技术的肌酸酐线性动态范围(LDR)从0.01 pM (DPV)扩展到1.0 M (CV),对于检测各种体液中不同的肌酸酐水平是必要的。所建立的肌酐检测方法的LOD和LOQ分别为1.15 pM和3.5 pM。该电化学传感器具有15.74 μApM-1cm-2的超高灵敏度。健康志愿者的体液中加入一定量的肌酐,以评估传感器在恢复过程中的效率。最后,对肾脏患者的血清、唾液和尿液样本进行肌酐水平分析。所开发的肌酸酐传感器的一个重要优点是它能够在唾液中进行无创的即时诊断,回收率超过90%。将该方法与标准的Jaffes比色法进行比较,证实了该方法的可靠性和扩展能力,适用于Jaffes法失效的样品。低LOD、高灵敏度、延长LDR和低成本使得采用该方法进行即时诊断成为可能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
期刊最新文献
Silk Fibroin-reinforced Stretchable, Hyperelastic Light-cured 3D Printed Elastomers for Flexible Sensors Intelligent Microfluidics: A Deep Learning-Integrated Platform for High-Accuracy Oocyte Membrane Permeability Characterization in Cryobiology Extracellular vesicles released in vitro from a Parkinson's Disease-like model: a combined biochemical and spectroscopic approach as proof of concept for the diagnosis of neurodegenerative diseases 3D FeMoO4/Fe7S8 Nanosheet Flower Composites as Highly Active Peroxidase-like Nanozymes for Colorimetric Sensing Enrofloxacin in Environmental Water Samples Blue-for-Positive: Colorimetric LAMP detection on paper-based microfluidic devices using a blue-shift indicator for instrument-free naked-eye readout
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1