Influence of Infrared Thermography Predictors in Dental Implant Osteotomies: An Ex Vivo Study

IF 3.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International dental journal Pub Date : 2025-03-30 DOI:10.1016/j.identj.2025.03.009
Gabriel Barriga-Yauri , Daniel Alvitez-Temoche , Franco Mauricio , Fran Espinoza-Carhuancho , Ivan Calderon , Julia Medina , Frank Mayta-Tovalino
{"title":"Influence of Infrared Thermography Predictors in Dental Implant Osteotomies: An Ex Vivo Study","authors":"Gabriel Barriga-Yauri ,&nbsp;Daniel Alvitez-Temoche ,&nbsp;Franco Mauricio ,&nbsp;Fran Espinoza-Carhuancho ,&nbsp;Ivan Calderon ,&nbsp;Julia Medina ,&nbsp;Frank Mayta-Tovalino","doi":"10.1016/j.identj.2025.03.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To evaluated the contribution of irrigation, drill type, motor, and dental implant system on infrared thermographic variations in osteotomies.</div></div><div><h3>Methods</h3><div>Osteotomy sites for 240 implants were prepared with three implant systems (Arcys, NeoBiotech and Osstem), with 80 samples analyzed in each group. Each group was further subdivided according to the drilling conditions (with and without irrigation) and motor type (Coxo, W&amp;H, Dentflex, Driller). The drill sequence included baseline, pilot, second and third drills at 1200 rpm and 40 Ncm. Infrared thermographic measurements were performed using a Fluke TiS55+ camera, with a resolution of 220 × 165 pixels and a temperature range of −20 °C to 450 °C. Statistical analysis consisted of ANOVA with Bonferroni post hoc test and linear regression model, with a view to evaluate the influence of the variables on final temperature changes.</div></div><div><h3>Results</h3><div>Irrigation caused a much lower temperature across all implant systems (<em>P</em> &lt; .001). When not irrigated, Arcys showed the highest temperatures, while in both NeoBiotech and Osstem the heat dissipated better. The Bonferroni post hoc test revealed no significant temperature difference existed among implant systems without irrigation. With irrigation, however, Arcys had a higher temperature than NeoBiotech and Osstem (<em>P</em> &lt; .001). The type of motor had no statistically significant influence on the temperature of the final drilling (<em>P</em> &gt; .05). Based on the regression analysis, the baseline, pilot, and second drill temperatures were the strongest predictors of the final drill temperature, with irrigation influencing the effects of the drill temperature.</div></div><div><h3>Conclusion</h3><div>Irrigation decreased the thermal stress during osteotomy, while NeoBiotech and Osstem showed better heat dispersing abilities. The motor type does not have a significant influence on the temperature differences. These findings establish the basic need for effective irrigation protocols to avoid thermal osteodisruption and promote osseointegration in implantology.</div></div>","PeriodicalId":13785,"journal":{"name":"International dental journal","volume":"75 3","pages":"Pages 1683-1690"},"PeriodicalIF":3.7000,"publicationDate":"2025-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International dental journal","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0020653925000802","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To evaluated the contribution of irrigation, drill type, motor, and dental implant system on infrared thermographic variations in osteotomies.

Methods

Osteotomy sites for 240 implants were prepared with three implant systems (Arcys, NeoBiotech and Osstem), with 80 samples analyzed in each group. Each group was further subdivided according to the drilling conditions (with and without irrigation) and motor type (Coxo, W&H, Dentflex, Driller). The drill sequence included baseline, pilot, second and third drills at 1200 rpm and 40 Ncm. Infrared thermographic measurements were performed using a Fluke TiS55+ camera, with a resolution of 220 × 165 pixels and a temperature range of −20 °C to 450 °C. Statistical analysis consisted of ANOVA with Bonferroni post hoc test and linear regression model, with a view to evaluate the influence of the variables on final temperature changes.

Results

Irrigation caused a much lower temperature across all implant systems (P < .001). When not irrigated, Arcys showed the highest temperatures, while in both NeoBiotech and Osstem the heat dissipated better. The Bonferroni post hoc test revealed no significant temperature difference existed among implant systems without irrigation. With irrigation, however, Arcys had a higher temperature than NeoBiotech and Osstem (P < .001). The type of motor had no statistically significant influence on the temperature of the final drilling (P > .05). Based on the regression analysis, the baseline, pilot, and second drill temperatures were the strongest predictors of the final drill temperature, with irrigation influencing the effects of the drill temperature.

Conclusion

Irrigation decreased the thermal stress during osteotomy, while NeoBiotech and Osstem showed better heat dispersing abilities. The motor type does not have a significant influence on the temperature differences. These findings establish the basic need for effective irrigation protocols to avoid thermal osteodisruption and promote osseointegration in implantology.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
红外热成像预测因子对牙科种植体截骨术的影响:一项体内外研究
目的探讨冲洗、钻孔类型、电机、种植体系统对截骨术红外热像变化的影响。方法采用Arcys、NeoBiotech和Osstem三种种植体系统制备240个种植体的截骨部位,每组80个样本进行分析。每组根据钻井条件(有和没有灌溉)和马达类型(Coxo、W&H、Dentflex、Driller)进一步细分。钻进顺序包括基线、先导、第二次和第三次钻进,转速为1200转/分,深度为40 Ncm。采用Fluke TiS55+红外热像仪进行红外热像测量,分辨率为220 × 165像素,温度范围为- 20°C至450°C。统计分析采用Bonferroni事后检验的方差分析和线性回归模型,以评估变量对最终温度变化的影响。结果灌溉使种植体系统的温度大大降低(P <;措施)。未灌溉时,arys的温度最高,而在NeoBiotech和Osstem中,热量消散得更好。Bonferroni事后测试显示,没有灌溉的种植体系统之间没有显著的温度差异。然而,在灌溉条件下,arys的温度高于NeoBiotech and system (P <;措施)。电机类型对最终钻进温度的影响无统计学意义(P >;. 05)。回归分析表明,基线温度、先导温度和二次钻温对最终钻温的预测效果最强,灌水影响钻温的效果。结论灌洗能降低截骨术中的热应力,而NeoBiotech和Osstem具有较好的散热能力。电机类型对温度差没有显著影响。这些发现建立了有效的灌溉方案的基本需求,以避免热骨破坏和促进种植体骨整合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International dental journal
International dental journal 医学-牙科与口腔外科
CiteScore
4.80
自引率
6.10%
发文量
159
审稿时长
63 days
期刊介绍: The International Dental Journal features peer-reviewed, scientific articles relevant to international oral health issues, as well as practical, informative articles aimed at clinicians.
期刊最新文献
Baicalin Alleviates LPS-Induced Apoptosis of Periodontal Ligament Cells Via Inhibiting Endoplasmic Reticulum Stress. Effect of Topical Fluoride Application Temperature on Recharge and Rerelease in Different Restorative Materials Prevalence of Awake and Sleep Bruxism in Israel Under Conditions of Collective Stress and Influential Factors. The Burden and Projections for 2036 of Periodontal Diseases in Asia From 1990 to 2021. Risk Prediction of Edentulism in Chinese Adults: Insights From the China Health and Retirement Longitudinal Study (CHARLS)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1