Automated polarization rotation for multi-axis rotational-anisotropy second harmonic generation experiments.

IF 1.7 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION Review of Scientific Instruments Pub Date : 2025-04-01 DOI:10.1063/5.0233827
Karna A Morey, Bryan T Fichera, Baiqing Lv, Zonqi Shen, Nuh Gedik
{"title":"Automated polarization rotation for multi-axis rotational-anisotropy second harmonic generation experiments.","authors":"Karna A Morey, Bryan T Fichera, Baiqing Lv, Zonqi Shen, Nuh Gedik","doi":"10.1063/5.0233827","DOIUrl":null,"url":null,"abstract":"<p><p>Rotational anisotropy second harmonic generation (RA-SHG) is a nonlinear optical technique used to probe the symmetry of condensed matter systems. Measuring the dependence of the SHG susceptibility on one or more external parameters, notably strain, field, temperature, or time delay, is an extremely powerful way to probe complex phases of quantum materials. Experimentally, extracting maximal information about the SHG susceptibility tensor requires measurements of S and P polarized input and output combinations, which naturally involves the rotation of the polarizers during data collection. For multi-axis experiments, this has proved challenging since polarization rotation is typically done manually. Automating this process eliminates labor constraints, reduces uncertainty due to low-frequency noise, and expands the type of multi-axis datasets that can be collected; however, it is difficult due to geometrical constraints within the setup. In this work, we design and implement low-cost, high-fidelity automated polarization rotators for use in multi-axis RA-SHG. These polarization rotators utilize an electrical slip ring to transfer power to the rotating RA-SHG optical setup as well as a miniature stepper motor to perform the polarization rotation. We demonstrate this automated system in time-resolved RA-SHG measurements in the non-centrosymmetric semiconductor GaAs. For the multi-axis measurements described above, this automated system permits data averaging over longer periods, vastly expedites data collection, and expands the setup measurement capability. This ultimately opens new frontiers in probing quantum materials using multiple tunable external parameters.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"96 4","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0233827","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Rotational anisotropy second harmonic generation (RA-SHG) is a nonlinear optical technique used to probe the symmetry of condensed matter systems. Measuring the dependence of the SHG susceptibility on one or more external parameters, notably strain, field, temperature, or time delay, is an extremely powerful way to probe complex phases of quantum materials. Experimentally, extracting maximal information about the SHG susceptibility tensor requires measurements of S and P polarized input and output combinations, which naturally involves the rotation of the polarizers during data collection. For multi-axis experiments, this has proved challenging since polarization rotation is typically done manually. Automating this process eliminates labor constraints, reduces uncertainty due to low-frequency noise, and expands the type of multi-axis datasets that can be collected; however, it is difficult due to geometrical constraints within the setup. In this work, we design and implement low-cost, high-fidelity automated polarization rotators for use in multi-axis RA-SHG. These polarization rotators utilize an electrical slip ring to transfer power to the rotating RA-SHG optical setup as well as a miniature stepper motor to perform the polarization rotation. We demonstrate this automated system in time-resolved RA-SHG measurements in the non-centrosymmetric semiconductor GaAs. For the multi-axis measurements described above, this automated system permits data averaging over longer periods, vastly expedites data collection, and expands the setup measurement capability. This ultimately opens new frontiers in probing quantum materials using multiple tunable external parameters.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于多轴旋转各向异性二次谐波发生实验的自动偏振旋转。
旋转各向异性二次谐波发生(RA-SHG)是一种用于探测凝聚态系统对称性的非线性光学技术。测量 SHG 感度对一个或多个外部参数(主要是应变、场、温度或时间延迟)的依赖性,是探测量子材料复杂相位的一种极其强大的方法。在实验中,要提取有关 SHG 感度张量的最大信息,需要测量 S 极化和 P 极化的输入和输出组合,这自然需要在数据收集过程中旋转极化器。对于多轴实验来说,由于偏振旋转通常需要人工完成,因此这已被证明是一项挑战。将这一过程自动化可以消除人力限制,减少低频噪声带来的不确定性,并扩大可收集的多轴数据集的类型;然而,由于装置内的几何限制,这一过程很难实现。在这项工作中,我们设计并实现了用于多轴 RA-SHG 的低成本、高保真自动偏振旋转器。这些偏振旋转器利用电气滑环将电源传输到旋转 RA-SHG 光学装置,并利用微型步进电机进行偏振旋转。我们在非中心对称半导体砷化镓的时间分辨 RA-SHG 测量中演示了这一自动化系统。对于上述多轴测量,该自动化系统允许在更长的时间段内进行数据平均,大大加快了数据收集速度,并扩展了设置测量能力。这最终为利用多个可调外部参数探测量子材料开辟了新的领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
期刊最新文献
A kHz laser desorption setup adapted to ultrafast gas-phase measurements of biomolecules. A fitness-guided adaptive genetic algorithm for near-field neutron coded imaging reconstruction. Compact high-pressure cell for in situ synchrotron powder x-ray diffraction featuring precise pressure and temperature control and a wide aperture for crystallographic studies under pressures of up to 400 MPa. Magnetic anomaly detection method based on principal component analysis and cascaded stochastic resonance. A novel rectangular aperture quadrupole electromagnet.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1