Analysis of Mechanical Characteristics and Operation Risk of Synchronous Condenser Rotor Under Dynamic Conditions With Typical Fault

IF 1.5 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Iet Electric Power Applications Pub Date : 2025-04-16 DOI:10.1049/elp2.70030
Minghan Ma, Hao Wang, Yucai Wu, Xinkai Zhu
{"title":"Analysis of Mechanical Characteristics and Operation Risk of Synchronous Condenser Rotor Under Dynamic Conditions With Typical Fault","authors":"Minghan Ma,&nbsp;Hao Wang,&nbsp;Yucai Wu,&nbsp;Xinkai Zhu","doi":"10.1049/elp2.70030","DOIUrl":null,"url":null,"abstract":"<p>To address the safety concerns regarding the mechanical performance of the rotor, a coupled electromagnetic–structural–fatigue simulation model is established to investigate the impact of transient shock processes under rotor interturn short circuit (RISC) and static air-gap eccentricity (SAGE) faults on the dynamic response and fatigue damage of the rotor shaft system during forced excitation operation of the synchronous condenser. First, the unbalanced magnetic pull (UMP) acting on the rotor is theoretically derived and its magnitude is obtained through electromagnetic simulation, followed by the calculation of the rotor's vibration response and corresponding experimental validation. Subsequently, a coupled electromagnetic–structural–fatigue simulation model is established to analyse the stress distribution of the rotor and verify its transient load-bearing capacity. Finally, a fatigue simulation is conducted to evaluate the impact of forced excitation fault operation on the rotor's service life. The results show that the rotor can maintain stable vibration in normal operation, and the amplitude of rotor characteristic frequency vibration increases during fault. Forced excitation operation with faults has a significant effect on the fatigue damage of the rotor shaft system. As the degree of fault increases, the fatigue life of the rotor shaft system decreases sharply.</p>","PeriodicalId":13352,"journal":{"name":"Iet Electric Power Applications","volume":"19 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2025-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/elp2.70030","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Electric Power Applications","FirstCategoryId":"5","ListUrlMain":"https://ietresearch.onlinelibrary.wiley.com/doi/10.1049/elp2.70030","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

To address the safety concerns regarding the mechanical performance of the rotor, a coupled electromagnetic–structural–fatigue simulation model is established to investigate the impact of transient shock processes under rotor interturn short circuit (RISC) and static air-gap eccentricity (SAGE) faults on the dynamic response and fatigue damage of the rotor shaft system during forced excitation operation of the synchronous condenser. First, the unbalanced magnetic pull (UMP) acting on the rotor is theoretically derived and its magnitude is obtained through electromagnetic simulation, followed by the calculation of the rotor's vibration response and corresponding experimental validation. Subsequently, a coupled electromagnetic–structural–fatigue simulation model is established to analyse the stress distribution of the rotor and verify its transient load-bearing capacity. Finally, a fatigue simulation is conducted to evaluate the impact of forced excitation fault operation on the rotor's service life. The results show that the rotor can maintain stable vibration in normal operation, and the amplitude of rotor characteristic frequency vibration increases during fault. Forced excitation operation with faults has a significant effect on the fatigue damage of the rotor shaft system. As the degree of fault increases, the fatigue life of the rotor shaft system decreases sharply.

Abstract Image

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
同步凝汽器转子典型故障动态工况机械特性及运行风险分析
为解决转子力学性能方面的安全问题,建立了转子转间短路(RISC)和静气隙偏心(SAGE)故障下瞬态冲击过程对同步冷凝器强制励磁运行时转子轴系动态响应和疲劳损伤的影响,建立了电磁-结构-疲劳耦合仿真模型。首先从理论上推导了作用在转子上的不平衡磁拉力(UMP),并通过电磁仿真得到了其大小,然后计算了转子的振动响应并进行了相应的实验验证。建立了电磁-结构-疲劳耦合仿真模型,分析了转子的应力分布,验证了转子的瞬态承载能力。最后进行了疲劳仿真,评估了强制励磁故障运行对转子使用寿命的影响。结果表明,转子在正常运行时能保持稳定的振动,故障时转子特征频率振动幅值增大。带故障强制励磁运行对转子轴系的疲劳损伤有重要影响。随着故障程度的增加,转子轴系的疲劳寿命急剧下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iet Electric Power Applications
Iet Electric Power Applications 工程技术-工程:电子与电气
CiteScore
4.80
自引率
5.90%
发文量
104
审稿时长
3 months
期刊介绍: IET Electric Power Applications publishes papers of a high technical standard with a suitable balance of practice and theory. The scope covers a wide range of applications and apparatus in the power field. In addition to papers focussing on the design and development of electrical equipment, papers relying on analysis are also sought, provided that the arguments are conveyed succinctly and the conclusions are clear. The scope of the journal includes the following: The design and analysis of motors and generators of all sizes Rotating electrical machines Linear machines Actuators Power transformers Railway traction machines and drives Variable speed drives Machines and drives for electrically powered vehicles Industrial and non-industrial applications and processes Current Special Issue. Call for papers: Progress in Electric Machines, Power Converters and their Control for Wave Energy Generation - https://digital-library.theiet.org/files/IET_EPA_CFP_PEMPCCWEG.pdf
期刊最新文献
Guest Editorial: Reliability Oriented Electrical Machine Systems: Topology, Design, Monitoring, Diagnostic Techniques, and Control Transformer Capacity Configuration Optimisation Considering Multi-Dimensional Interaction Characteristics of User-Side Resources Experimental Validation of a Spoke Type Ferrite Permanent Magnet Machine Design for Heavy-Duty Traction Applications Forced Air-Cooling of Modular Flux Switching PM Machines Using Flux Gaps as Cooling Channels PMSM Control via Composite Logarithmic Sliding Mode Control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1