{"title":"The performance of hot-dip galvanized composite beams made of high and higher strength steel in standard fire resistance tests","authors":"Maria-Mirabela Firan ,&nbsp;Justus Frenz ,&nbsp;Jie Li ,&nbsp;Annika Kapfhammer ,&nbsp;Luke Bisby ,&nbsp;Jochen Zehfuß ,&nbsp;Martin Mensinger","doi":"10.1016/j.firesaf.2025.104400","DOIUrl":null,"url":null,"abstract":"<div><div>The lower emissivity of hot-dip galvanized steel sections as compared with non-galvanized steel, particularly at temperatures below 500 °C, results in slower heating when exposed to fire, thus enabling fire resistance ratings of R30 for compact cross-sections without additional passive fire protection. Using galvanized high and higher-strength steels allows R30 fire resistance to be achieved in composite beams more efficiently and cost-effectively. These ideas are investigated experimentally and via numerical analyses in this paper.</div><div>Large-scale standard fire resistance tests are presented to evaluate the performance of hot-dip galvanized composite beams under thermal and mechanical loads. The tests include a variety of beam geometries and depths, using steel grades S460M and S690QL. Single-symmetrical beams were designed with a reduced top flange thicknesses and compact bottom flanges to optimize overall depth and improve thermal response during fire testing. The temperature-dependent material properties of the S460M and S690QL steels is characterised, including steady state and transient tensile tests on both steels, and the results are compared with those given in DIN EN 1993-1-2. Hot-dip galvanized secondary beams with different connection types were connected in the middle of the beams during the large scale fire resistance tests so as to investigate temperatures experienced by differing connection details. The collected test data are used to validate and verify finite element models for such composite beams when exposed to standard fire exposures, alongside further parametric studies examining elements such as cross sectional geometry of the composite beam, the degree of shear connection, and the overall length of the beams. The outcomes of these studies contribute to the determination of the minimum required degree of stud shear connection for hot-dip galvanized composite beams in standard fire scenarios.</div></div>","PeriodicalId":50445,"journal":{"name":"Fire Safety Journal","volume":"154 ","pages":"Article 104400"},"PeriodicalIF":3.3000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety Journal","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0379711225000645","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/17 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

The lower emissivity of hot-dip galvanized steel sections as compared with non-galvanized steel, particularly at temperatures below 500 °C, results in slower heating when exposed to fire, thus enabling fire resistance ratings of R30 for compact cross-sections without additional passive fire protection. Using galvanized high and higher-strength steels allows R30 fire resistance to be achieved in composite beams more efficiently and cost-effectively. These ideas are investigated experimentally and via numerical analyses in this paper.
Large-scale standard fire resistance tests are presented to evaluate the performance of hot-dip galvanized composite beams under thermal and mechanical loads. The tests include a variety of beam geometries and depths, using steel grades S460M and S690QL. Single-symmetrical beams were designed with a reduced top flange thicknesses and compact bottom flanges to optimize overall depth and improve thermal response during fire testing. The temperature-dependent material properties of the S460M and S690QL steels is characterised, including steady state and transient tensile tests on both steels, and the results are compared with those given in DIN EN 1993-1-2. Hot-dip galvanized secondary beams with different connection types were connected in the middle of the beams during the large scale fire resistance tests so as to investigate temperatures experienced by differing connection details. The collected test data are used to validate and verify finite element models for such composite beams when exposed to standard fire exposures, alongside further parametric studies examining elements such as cross sectional geometry of the composite beam, the degree of shear connection, and the overall length of the beams. The outcomes of these studies contribute to the determination of the minimum required degree of stud shear connection for hot-dip galvanized composite beams in standard fire scenarios.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高、高强度钢热浸镀锌组合梁在标准耐火试验中的性能
与非镀锌钢相比,热浸镀锌钢板的发射率较低,特别是在温度低于500°C时,暴露在火中加热较慢,因此在没有额外被动防火保护的情况下,紧凑截面的耐火等级达到R30。使用镀锌高强度钢和更高强度钢,可以在复合梁中更有效、更经济地实现R30耐火。本文通过实验和数值分析对这些观点进行了研究。为评价热浸镀锌复合梁在热载荷和机械载荷下的性能,提出了大型标准耐火试验。测试包括各种梁的几何形状和深度,使用钢牌号S460M和S690QL。单对称梁的设计减少了顶部法兰厚度,底部法兰紧凑,以优化整体深度,改善火灾测试时的热响应。对S460M和S690QL钢的温度相关材料性能进行了表征,包括对两种钢进行稳态和瞬态拉伸试验,并将结果与DIN EN 1993-1-2中给出的结果进行了比较。在大型耐火试验中,采用不同连接方式的热浸镀锌二次梁连接在梁的中间,以研究不同连接方式所经历的温度。收集的测试数据用于验证和验证这种复合梁在暴露于标准火灾时的有限元模型,以及进一步的参数研究,检查复合梁的横截面几何形状、剪切连接程度和梁的总长度等元素。这些研究的结果有助于确定在标准火灾情况下热浸镀锌复合梁的螺柱剪切连接的最小要求程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Fire Safety Journal
Fire Safety Journal 工程技术-材料科学:综合
CiteScore
5.70
自引率
9.70%
发文量
153
审稿时长
60 days
期刊介绍: Fire Safety Journal is the leading publication dealing with all aspects of fire safety engineering. Its scope is purposefully wide, as it is deemed important to encourage papers from all sources within this multidisciplinary subject, thus providing a forum for its further development as a distinct engineering discipline. This is an essential step towards gaining a status equal to that enjoyed by the other engineering disciplines.
期刊最新文献
Characterizing the hazards of vehicle fires in the WUI Simulations of firebrand-driven fire spread in landscape-scale Wildland-Urban-Interface (WUI) and urban conflagration models Scaling analysis of regime transitions during transient gasification of a non-charring solid fuel An experimental investigation of fire dynamics in large-diameter industrial exhaust ducts and development of a scaled testing approach High-speed thermal imaging of disk-shaped firebrands in a wind tunnel
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1