[Quantitative integrated backscatter characteristics in the normal and infarcted canine myocardium].

Journal of cardiography Pub Date : 1986-12-01
T Shimazu, H Nishioka, M Fujiwara, T Matsuyama, H Ozaki, Y Hamanaka, A Kitabatake, M Inoue, T Kamada, M Matsumoto
{"title":"[Quantitative integrated backscatter characteristics in the normal and infarcted canine myocardium].","authors":"T Shimazu,&nbsp;H Nishioka,&nbsp;M Fujiwara,&nbsp;T Matsuyama,&nbsp;H Ozaki,&nbsp;Y Hamanaka,&nbsp;A Kitabatake,&nbsp;M Inoue,&nbsp;T Kamada,&nbsp;M Matsumoto","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>To develop ultrasonic cardiac tissue characterization, serial changes in intensity of backscattered ultrasound from the normal and infarcted myocardium were studied in vitro, with frequency-domain analysis. As an index of backscattered signal intensity, quantitative integrated backscatter [(10 X log-S2/S1)] (dB), S1 and S2 = areas of power spectra of digitized (sample rate = 100 MHz, 8 bits) ultrasonic signals from a perfect reflector and good specimens) were calculated for 60 regions of the myocardium (N = 20, MI = 40) excised from 10 dogs 3 days, 1, 2, and 4 weeks after coronary artery ligation in 2, 3, 3, and 2 dogs, respectively. The myocardial specimens and a stainless steel reflector were mounted at the focal distance of a newly-developed wide-band transducer having a center frequency of 4.0 MHz, in a water bath filled with degassed physiological saline. Tissue concentrations of hydroxyproline (HP) were also established using a HPLC (Hitachi amino acid analyzer model 835). The results obtained were as follows: 1. No significant changes in the integrated backscatter of the normal myocardium were observed throughout the experimental period (3 days = -52.5 +/- 0.7, one week = -53.6 +/- 1.8, two weeks = -51.6 +/- 0.8, four weeks = -52.8 +/- 1.4 (dB) (mean +/- SE). 2. Integrated backscatter of the infarcted myocardium [3 days = -47.3 +/- 0.6, one week = -49.2 +/- 1.3, two weeks = -40.7 +/- 1.3, four weeks = -39.6 +/- 2.0 (dB)] was significantly increased compared with the integrated backscatter of the normal myocardium in the early stage of myocardial infarction, before tissue concentrations of hydroxyproline increased, as well as in the chronic stage of myocardial infarction. 3. Results of histological examinations suggest that minute changes in structure, such as interstitial edema or neovascular proliferations, may be the cause of an early increase in integrated backscatter. The results suggest that quantitative integrated backscatter is a sensitive parameter for detecting both early and old myocardial infarction by cardiac tissue characterization.</p>","PeriodicalId":77734,"journal":{"name":"Journal of cardiography","volume":"16 4","pages":"799-808"},"PeriodicalIF":0.0000,"publicationDate":"1986-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiography","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To develop ultrasonic cardiac tissue characterization, serial changes in intensity of backscattered ultrasound from the normal and infarcted myocardium were studied in vitro, with frequency-domain analysis. As an index of backscattered signal intensity, quantitative integrated backscatter [(10 X log-S2/S1)] (dB), S1 and S2 = areas of power spectra of digitized (sample rate = 100 MHz, 8 bits) ultrasonic signals from a perfect reflector and good specimens) were calculated for 60 regions of the myocardium (N = 20, MI = 40) excised from 10 dogs 3 days, 1, 2, and 4 weeks after coronary artery ligation in 2, 3, 3, and 2 dogs, respectively. The myocardial specimens and a stainless steel reflector were mounted at the focal distance of a newly-developed wide-band transducer having a center frequency of 4.0 MHz, in a water bath filled with degassed physiological saline. Tissue concentrations of hydroxyproline (HP) were also established using a HPLC (Hitachi amino acid analyzer model 835). The results obtained were as follows: 1. No significant changes in the integrated backscatter of the normal myocardium were observed throughout the experimental period (3 days = -52.5 +/- 0.7, one week = -53.6 +/- 1.8, two weeks = -51.6 +/- 0.8, four weeks = -52.8 +/- 1.4 (dB) (mean +/- SE). 2. Integrated backscatter of the infarcted myocardium [3 days = -47.3 +/- 0.6, one week = -49.2 +/- 1.3, two weeks = -40.7 +/- 1.3, four weeks = -39.6 +/- 2.0 (dB)] was significantly increased compared with the integrated backscatter of the normal myocardium in the early stage of myocardial infarction, before tissue concentrations of hydroxyproline increased, as well as in the chronic stage of myocardial infarction. 3. Results of histological examinations suggest that minute changes in structure, such as interstitial edema or neovascular proliferations, may be the cause of an early increase in integrated backscatter. The results suggest that quantitative integrated backscatter is a sensitive parameter for detecting both early and old myocardial infarction by cardiac tissue characterization.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[犬正常心肌和梗死心肌的定量后向散射特征]。
为了建立超声心脏组织特征,我们在体外研究了正常和梗死心肌的背散射超声强度的一系列变化,并进行了频域分析。作为后向散射信号强度指标,对10只狗(2、3、3、2)冠状动脉结扎术后3天、1、2、4周切除的60个心肌区域(N = 20, MI = 40),分别计算后向散射定量积分[(10 X log-S2/S1)] (dB), S1和S2 =数字化后(采样率= 100 MHz, 8比特)超声信号的功率谱面积。将心肌标本和不锈钢反射镜安装在中心频率为4.0 MHz的新型宽带换能器的焦距处,置于充满脱气生理盐水的水浴中。采用高效液相色谱法(日立835型氨基酸分析仪)测定组织中羟脯氨酸(HP)的浓度。实验结果如下:1。在整个实验期间(3天= -52.5 +/- 0.7,1周= -53.6 +/- 1.8,2周= -51.6 +/- 0.8,4周= -52.8 +/- 1.4 (dB)(平均+/- SE),正常心肌的综合后向散射无明显变化。2. 心肌梗死早期、组织羟脯氨酸浓度升高前及心肌梗死慢慢期,梗死心肌综合后向散射[3天= -47.3 +/- 0.6,1周= -49.2 +/- 1.3,2周= -40.7 +/- 1.3,4周= -39.6 +/- 2.0 (dB)]较正常心肌综合后向散射明显增加。3.组织学检查结果提示,微小的结构变化,如间质水肿或新生血管增生,可能是早期综合后向散射增加的原因。结果表明,定量积分后向散射是通过心肌组织特征检测早期和老年心肌梗死的敏感参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Mechanical and electrocardiographic sequence of coronary artery occlusion: an echocardiographic study during coronary angioplasty]. [Collateral circulation during exercise-induced angina: evaluation by coronary angiography]. [Echo and Doppler cardiographic findings of isolated quadricuspid aortic valve: a case report and a review of the literature]. [Quantitative integrated backscatter characteristics in the normal and infarcted canine myocardium]. Clinical validity of washout time constant images obtained by digital subtraction angiography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1