Development of a method for determination of methylene chloride emissions at stationary sources.

F E Butler, E A Coppedge, J C Suggs, J E Knoll, M R Midgett, A L Sykes, M W Hartman, J L Steger
{"title":"Development of a method for determination of methylene chloride emissions at stationary sources.","authors":"F E Butler, E A Coppedge, J C Suggs, J E Knoll, M R Midgett, A L Sykes, M W Hartman, J L Steger","doi":"10.1080/08940630.1988.10466378","DOIUrl":null,"url":null,"abstract":"Prior to source sampling, laboratory experiments were conducted to determine the best sample container in which to collect an integrated sample. It was found that CH/sub 2/Cl/sub 2/ remained stable in Tedlar bags for at least four weeks. The analytical method selected was gas chromatography with flame ionization detection (GC/FID). During the field portion of the study, both manufacturer and user emissions sources of CH/sub 2/Cl/sub 2/ were tested. Multiple sets of simultaneous quadruplicate bag samples were collected to determine the precision of both sampling and analysis in the field. All samples were analyzed at the test site after collection and then returned to Research Triangle Park. Samples were subsequently reanalyzed in the laboratories of Radian and the US EPA using three GC/FID instruments and two types of GC columns. The range of concentrations from the sources was 100 ppm to 27,000 ppm CH/sub 2/Cl/sub 2/. A statistical analysis of samples collected simultaneously showed no difference in the samples, proving good precision in both sampling and analysis. Some of the sample bags returned from the test sites developed leaks indicating that immediate on-site analysis is best. A comparison of results obtained in the field and the two laboratories showed thatmore » inter- and intra-laboratory precision was within 10%.« less","PeriodicalId":77731,"journal":{"name":"JAPCA","volume":"38 3","pages":"272-7"},"PeriodicalIF":0.0000,"publicationDate":"1988-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/08940630.1988.10466378","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAPCA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08940630.1988.10466378","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Prior to source sampling, laboratory experiments were conducted to determine the best sample container in which to collect an integrated sample. It was found that CH/sub 2/Cl/sub 2/ remained stable in Tedlar bags for at least four weeks. The analytical method selected was gas chromatography with flame ionization detection (GC/FID). During the field portion of the study, both manufacturer and user emissions sources of CH/sub 2/Cl/sub 2/ were tested. Multiple sets of simultaneous quadruplicate bag samples were collected to determine the precision of both sampling and analysis in the field. All samples were analyzed at the test site after collection and then returned to Research Triangle Park. Samples were subsequently reanalyzed in the laboratories of Radian and the US EPA using three GC/FID instruments and two types of GC columns. The range of concentrations from the sources was 100 ppm to 27,000 ppm CH/sub 2/Cl/sub 2/. A statistical analysis of samples collected simultaneously showed no difference in the samples, proving good precision in both sampling and analysis. Some of the sample bags returned from the test sites developed leaks indicating that immediate on-site analysis is best. A comparison of results obtained in the field and the two laboratories showed thatmore » inter- and intra-laboratory precision was within 10%.« less
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
固定源二氯甲烷排放测定方法的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The superfund remedial action decision process: a review of fifty records of decision. Indoor ozone exposures. Particulate and nicotine sampling in public facilities and offices. Air levels and mutagenicity of PM-10 in an indoor ice arena. Summary of the 1989 EPA/A&WMA International symposium: measurement of toxic and related air pollutants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1