[Radiation exposure in whole body and cranial CT studies in relation to parameters of the examination technic].

Computertomographie Pub Date : 1983-09-01
B J Fiebach, K Ewen, H B Makoski
{"title":"[Radiation exposure in whole body and cranial CT studies in relation to parameters of the examination technic].","authors":"B J Fiebach,&nbsp;K Ewen,&nbsp;H B Makoski","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The article gives the organ doses for whole body CT examinations of the thoracic region, the upper abdomen, the mesogastric and pelvic regions as well as of the lumbar vertebral column and for CT scanning of the skull. The examinations were performed using an Alderson-Rando phantom with the whole body computer tomograph Somatom DR2 supplied by Siemens and with the skull computer tomograph Siretom 2000, also supplied by Siemens. It was found that the magnitude of radiation exposure of the patient depends not only on instrument-specific properties, but also to a very large measure on the examination parameters and techniques which can vary considerably from one clinic to another.</p>","PeriodicalId":79210,"journal":{"name":"Computertomographie","volume":"3 3","pages":"108-11"},"PeriodicalIF":0.0000,"publicationDate":"1983-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computertomographie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The article gives the organ doses for whole body CT examinations of the thoracic region, the upper abdomen, the mesogastric and pelvic regions as well as of the lumbar vertebral column and for CT scanning of the skull. The examinations were performed using an Alderson-Rando phantom with the whole body computer tomograph Somatom DR2 supplied by Siemens and with the skull computer tomograph Siretom 2000, also supplied by Siemens. It was found that the magnitude of radiation exposure of the patient depends not only on instrument-specific properties, but also to a very large measure on the examination parameters and techniques which can vary considerably from one clinic to another.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[全身辐射暴露与头颅CT研究与检查技术参数的关系]。
本文给出了胸椎、上腹部、胃系膜区、骨盆区、腰椎全身CT检查和颅骨CT扫描的器官剂量。检查采用Alderson-Rando假体,采用西门子公司提供的Somatom DR2全身计算机层析仪和西门子公司提供的Siretom 2000颅骨计算机层析仪。研究发现,患者的辐射暴露程度不仅取决于仪器的特定特性,而且在很大程度上取决于检查参数和技术,这些参数和技术在不同诊所之间可能有很大差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Transrectal prostate sonography in early cancer recognition]. [Significance of digital subtraction angiography (DSA) in the evaluation of reconstructive vascular interventions]. [The lobus venae anonymae]. [Computer tomography image of a triple anlage of the stomach]. [Computer tomography aspects in the diagnosis of tuberculosis in the area of the abdomen and urogenital tract].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1