A method for the calculation of renal clearance based on a single plasma sample.

L Jacobsson
{"title":"A method for the calculation of renal clearance based on a single plasma sample.","authors":"L Jacobsson","doi":"10.1111/j.1475-097x.1983.tb00712.x","DOIUrl":null,"url":null,"abstract":"<p><p>A formula has been derived for the calculation of renal clearance with the use of a single plasma sample. The formula is based on a one-compartment model. A small correction for non-immediate mixing and non-uniform distribution of the tracer was calculated from empirical data. The accuracy in the calculation method depends on how exactly the distribution volume is known and at what time the blood sample is taken. The expected standard deviation in the clearance value was calculated from data of mean value and spread for the distribution volume of 99Tcm-DTPA. In an investigation of 39 subjects with 99Tcm-DTPA, a standard deviation of 5 to 6 ml/min was obtained in comparison with a standard method for clearance calculation. This value is in good agreement with the expected one.</p>","PeriodicalId":77071,"journal":{"name":"Clinical physiology (Oxford, England)","volume":"3 4","pages":"297-305"},"PeriodicalIF":0.0000,"publicationDate":"1983-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.1475-097x.1983.tb00712.x","citationCount":"202","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical physiology (Oxford, England)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/j.1475-097x.1983.tb00712.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 202

Abstract

A formula has been derived for the calculation of renal clearance with the use of a single plasma sample. The formula is based on a one-compartment model. A small correction for non-immediate mixing and non-uniform distribution of the tracer was calculated from empirical data. The accuracy in the calculation method depends on how exactly the distribution volume is known and at what time the blood sample is taken. The expected standard deviation in the clearance value was calculated from data of mean value and spread for the distribution volume of 99Tcm-DTPA. In an investigation of 39 subjects with 99Tcm-DTPA, a standard deviation of 5 to 6 ml/min was obtained in comparison with a standard method for clearance calculation. This value is in good agreement with the expected one.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种基于单个血浆样本计算肾脏清除率的方法。
推导了一个公式,用于计算使用单一血浆样品的肾脏清除率。这个公式是基于一个单室模型。根据经验数据对示踪剂的非立即混合和非均匀分布进行了小的修正。计算方法的准确性取决于如何准确地知道分布体积以及在什么时候采集血液样本。根据99Tcm-DTPA分布体积的均值和差值数据计算间隙值的期望标准差。在对39名使用99Tcm-DTPA的受试者的调查中,与计算清除率的标准方法相比,得到的标准偏差为5 ~ 6ml /min。该值与预期值完全一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Subdural hematoma presenting as trigeminal neuralgia: A case report. Identification of a mannitol transporter, AgMaT1, in celery phloem. Pacing-induced palmar sweating evaluated by unique hygrometer: possible implications of sympathetic activation during tachycardia. Into the 20th volume and the 21st century Non-linear cardiac dynamics and morning dip: an unsound circadian rhythm.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1