[Tocopherol Acetate Reference Standard (Control 941) of the National Institute of Health Sciences].

A Kitajima, K Maekawa, K Yoshii, H Komatsu, T Tanimoto, S Okada
{"title":"[Tocopherol Acetate Reference Standard (Control 941) of the National Institute of Health Sciences].","authors":"A Kitajima,&nbsp;K Maekawa,&nbsp;K Yoshii,&nbsp;H Komatsu,&nbsp;T Tanimoto,&nbsp;S Okada","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The raw material of tocopherol acetate was tested for the preparation of the \"Tocopherol Acetate Reference Standard (Control 941)\". Analytical data obtained were as follows: infrared spectrum, the same as that of the Tocopherol Acetate Reference Standard (Control 919); specific absorbance, E1(1%)cm (284nm) = 44.5; thin-layer chromatography, no impurities were detected until 50.0 micrograms; high-performance liquid chromatography (HPLC), 2-3 impurities were detected and the amount was estimated to be about 1%; assay by HPLC, 100.8%. Based on the above results, the raw material was authorized as the Japanese Pharmacopoeia Reference Standard (Control 941).</p>","PeriodicalId":11656,"journal":{"name":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","volume":" 114","pages":"119-21"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The raw material of tocopherol acetate was tested for the preparation of the "Tocopherol Acetate Reference Standard (Control 941)". Analytical data obtained were as follows: infrared spectrum, the same as that of the Tocopherol Acetate Reference Standard (Control 919); specific absorbance, E1(1%)cm (284nm) = 44.5; thin-layer chromatography, no impurities were detected until 50.0 micrograms; high-performance liquid chromatography (HPLC), 2-3 impurities were detected and the amount was estimated to be about 1%; assay by HPLC, 100.8%. Based on the above results, the raw material was authorized as the Japanese Pharmacopoeia Reference Standard (Control 941).

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[国家卫生科学研究所醋酸生育酚参考标准(Control 941)]。
为编制《醋酸生育酚参比标准品(Control 941)》,对乙酸生育酚原料进行了测定。获得的分析数据如下:红外光谱与醋酸生育酚参比标准品(Control 919)相同;比吸光度,E1(1%)cm (284nm) = 44.5;薄层色谱法,50.0微克前未检出杂质;高效液相色谱法检出2-3个杂质,估计含量约为1%;高效液相色谱法测定,100.8%。根据上述结果,该原料被批准为日本药典参考标准(Control 941)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Cyanocobalamin Reference Standard (Control 951) of the National Institute of Health Sciences]. [dl-Camphor Reference Standard (Control 951) of the National Institute of Health Sciences]. [Lysozyme Reference Standard (Control 951) of the National Institute of Health Sciences]. [The Somatropin Reference Standard (Control 951) of the National Institute of Health Sciences]. [Studies on "Fast Green FCF Standard" for the dye standard on the National Institute of Health Sciences].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1