Anti-insulin antibodies in insulin immunometric assays: a still possible pitfall.

R Sapin
{"title":"Anti-insulin antibodies in insulin immunometric assays: a still possible pitfall.","authors":"R Sapin","doi":"10.1515/cclm.1997.35.5.365","DOIUrl":null,"url":null,"abstract":"<p><p>Insulin was assayed directly using radioimmunoassay and immunometric assay in 31 sera containing anti-insulin antibodies. Anti-insulin antibodies were determined by radio-binding-assay. Insulin measurements were compared with those of free (unbound to antibodies, polyethylene glycol precipitated) insulin measurements. Compared with free insulin concentrations, radioimmunoassay and immunometric assay yielded falsely increased insulin results. The degree of overestimation by radioimmunoassay and by immunometric assay correlated with the anti-insulin antibody value. Anti-insulin antibodies still remain a possible pitfall in the insulin-specific immunometric assays which are now being widely used.</p>","PeriodicalId":77119,"journal":{"name":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","volume":"35 5","pages":"365-7"},"PeriodicalIF":0.0000,"publicationDate":"1997-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1515/cclm.1997.35.5.365","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cclm.1997.35.5.365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

Insulin was assayed directly using radioimmunoassay and immunometric assay in 31 sera containing anti-insulin antibodies. Anti-insulin antibodies were determined by radio-binding-assay. Insulin measurements were compared with those of free (unbound to antibodies, polyethylene glycol precipitated) insulin measurements. Compared with free insulin concentrations, radioimmunoassay and immunometric assay yielded falsely increased insulin results. The degree of overestimation by radioimmunoassay and by immunometric assay correlated with the anti-insulin antibody value. Anti-insulin antibodies still remain a possible pitfall in the insulin-specific immunometric assays which are now being widely used.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
胰岛素免疫测定法中的抗胰岛素抗体:一个仍然可能存在的缺陷。
采用放射免疫法和免疫分析法对31份含胰岛素抗体的血清进行胰岛素检测。用放射结合法测定抗胰岛素抗体。将胰岛素测量值与游离(未结合抗体,聚乙二醇沉淀)胰岛素测量值进行比较。与游离胰岛素浓度相比,放射免疫测定法和免疫测定法产生了错误的胰岛素升高结果。放射免疫法和免疫计量法的高估程度与抗胰岛素抗体值相关。抗胰岛素抗体仍然是目前广泛使用的胰岛素特异性免疫测定中可能存在的缺陷。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Synthesis and Characterization of Fatty Acid Furfuryl Ester Mixtures: Biodiesel from Furfuryl Alcohol Determination of Agmatine Rate by Spectrofluorimetric Method in Alkaline Medium: Optimization and Application on Shrimp. Increased Oxidative/Nitrosative Stress in Common Metabolic Diseases in Gaziantep Region nvironmental Monitoring of NOX, Total Oxidants and the Implications for Photochemistry of Air Pollution over Ilorin Shed, Nigeria Short Communication
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1