The optimized use of gas chromatography-mass spectrometry and high performance liquid chromatography to analyse the serum bile acids of patients with metabolic cholestasis and peroxisomal disorders.
F Courillon, M F Gerhardt, A Myara, F Rocchiccioli, F Trivin
{"title":"The optimized use of gas chromatography-mass spectrometry and high performance liquid chromatography to analyse the serum bile acids of patients with metabolic cholestasis and peroxisomal disorders.","authors":"F Courillon, M F Gerhardt, A Myara, F Rocchiccioli, F Trivin","doi":"10.1515/cclm.1997.35.12.919","DOIUrl":null,"url":null,"abstract":"<p><p>We have measured the bile acids in human serum as methyl ester-trimethylsilyl ethers by gas chromatography-mass spectrometry (GC-MS) using an electron ionization procedure. The overall method was validated and the detection limit (0.4 mumol/l), linearity (2-30 mumol/l), intra-day and inter-day precision, accuracy and recovery (96.2% for nor-23-deoxycholic acid as internal standard) were measured. Serum C24-bile acids profiles from 43 cholestatic patients were measured by GC-MS and by HPLC. The results obtained with the two methods were well correlated and the criteria for selecting either HPLC or GC-MS identified. The serum C24- and C27-bile acids and C29 dicarboxylic bile acid profiles for patients with generalized peroxisomal deficiencies, like Zellweger syndrome (n = 5), neonatal adrenoleukodystrophy (n = 1), infantile Refsum disease (n = 2) and from a single peroxisomal deficiency (n = 1) were also measured by GC-MS.</p>","PeriodicalId":77119,"journal":{"name":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","volume":"35 12","pages":"919-22"},"PeriodicalIF":0.0000,"publicationDate":"1997-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1515/cclm.1997.35.12.919","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cclm.1997.35.12.919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
We have measured the bile acids in human serum as methyl ester-trimethylsilyl ethers by gas chromatography-mass spectrometry (GC-MS) using an electron ionization procedure. The overall method was validated and the detection limit (0.4 mumol/l), linearity (2-30 mumol/l), intra-day and inter-day precision, accuracy and recovery (96.2% for nor-23-deoxycholic acid as internal standard) were measured. Serum C24-bile acids profiles from 43 cholestatic patients were measured by GC-MS and by HPLC. The results obtained with the two methods were well correlated and the criteria for selecting either HPLC or GC-MS identified. The serum C24- and C27-bile acids and C29 dicarboxylic bile acid profiles for patients with generalized peroxisomal deficiencies, like Zellweger syndrome (n = 5), neonatal adrenoleukodystrophy (n = 1), infantile Refsum disease (n = 2) and from a single peroxisomal deficiency (n = 1) were also measured by GC-MS.