Determination of HbA1c in the presence of haemoglobin variants: comparison of three HPLC techniques.

M Carta, G Dall'Olio, G Soffiati
{"title":"Determination of HbA1c in the presence of haemoglobin variants: comparison of three HPLC techniques.","authors":"M Carta,&nbsp;G Dall'Olio,&nbsp;G Soffiati","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The presence of Hb variants may cause analytical interference in HbA1c values measured with the HPLC techniques currently used in Italian laboratories. In this study performance of a new HPLC system, (HA-8140, Menarini) was compared with two other traditional HPLC systems (HA-8121, Menarini and Diamat, Bio-Rad). The HA-8140 system detects the Hb variant possibly present in an independent peak. The integration area of such a peak is not computed in the calculation of the percentage value of HbA1c. In this manner the underestimation of values obtained with traditional HPLC systems is avoided.</p>","PeriodicalId":77119,"journal":{"name":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","volume":"35 12","pages":"923-5"},"PeriodicalIF":0.0000,"publicationDate":"1997-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The presence of Hb variants may cause analytical interference in HbA1c values measured with the HPLC techniques currently used in Italian laboratories. In this study performance of a new HPLC system, (HA-8140, Menarini) was compared with two other traditional HPLC systems (HA-8121, Menarini and Diamat, Bio-Rad). The HA-8140 system detects the Hb variant possibly present in an independent peak. The integration area of such a peak is not computed in the calculation of the percentage value of HbA1c. In this manner the underestimation of values obtained with traditional HPLC systems is avoided.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血红蛋白变异时HbA1c的测定:三种HPLC技术的比较。
Hb变异的存在可能会导致目前在意大利实验室使用的HPLC技术测量的HbA1c值的分析干扰。在本研究中,比较了一种新型高效液相色谱体系(HA-8140, Menarini)和两种传统高效液相色谱体系(HA-8121, Menarini和Diamat, Bio-Rad)。HA-8140系统检测Hb变异可能存在于一个独立的峰中。在计算HbA1c百分比值时,不计算该峰的积分面积。这样就避免了用传统HPLC系统得到的值的低估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Synthesis and Characterization of Fatty Acid Furfuryl Ester Mixtures: Biodiesel from Furfuryl Alcohol Determination of Agmatine Rate by Spectrofluorimetric Method in Alkaline Medium: Optimization and Application on Shrimp. Increased Oxidative/Nitrosative Stress in Common Metabolic Diseases in Gaziantep Region nvironmental Monitoring of NOX, Total Oxidants and the Implications for Photochemistry of Air Pollution over Ilorin Shed, Nigeria Short Communication
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1