{"title":"Balancing the caloric-induced nystagmus velocity with cold air and water.","authors":"K J Munro, C L Bonnington","doi":"10.3109/03005364000000081","DOIUrl":null,"url":null,"abstract":"<p><p>A useful alternative to the traditional water caloric is to use an air stimulus. However, the caloric test has not been standardized and a range of parameters are being used in different audiology clinics. The aim of this study was to determine cold air parameters that resulted in a similar slow-component eye velocity to that for water irrigation. Twelve normal subjects underwent caloric testing using air temperatures in the range 18-33 degrees C. The duration and air-flow rate were held constant at 60 s and 5 l/min. A water irrigation at 30 degrees C for 30 s and delivering 150 ml resulted in a mean slow-component eye velocity of 17 degrees/s. An equal response was obtained with an air temperature of 21.0 degrees C. Further work is required to find equivalent air and water responses for other combinations of parameters.</p>","PeriodicalId":75616,"journal":{"name":"British journal of audiology","volume":"32 5","pages":"301-4"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/03005364000000081","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British journal of audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/03005364000000081","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
A useful alternative to the traditional water caloric is to use an air stimulus. However, the caloric test has not been standardized and a range of parameters are being used in different audiology clinics. The aim of this study was to determine cold air parameters that resulted in a similar slow-component eye velocity to that for water irrigation. Twelve normal subjects underwent caloric testing using air temperatures in the range 18-33 degrees C. The duration and air-flow rate were held constant at 60 s and 5 l/min. A water irrigation at 30 degrees C for 30 s and delivering 150 ml resulted in a mean slow-component eye velocity of 17 degrees/s. An equal response was obtained with an air temperature of 21.0 degrees C. Further work is required to find equivalent air and water responses for other combinations of parameters.