The influence of body temperature on transient evoked otoacoustic emissions.

E Seifert, A Lamprecht-Dinnesen, B Asfour, H Rotering, H G Bone, H H Scheld
{"title":"The influence of body temperature on transient evoked otoacoustic emissions.","authors":"E Seifert,&nbsp;A Lamprecht-Dinnesen,&nbsp;B Asfour,&nbsp;H Rotering,&nbsp;H G Bone,&nbsp;H H Scheld","doi":"10.3109/03005364000000090","DOIUrl":null,"url":null,"abstract":"<p><p>Thirty patients undergoing open heart surgery under induced hypothermia had transient evoked otoacoustic emissions (TEOAE) recorded during cooling to 26.07 degrees C (standard deviation (SD) 4.25 degrees C) vesically measured temperature and 24.86 degrees C (SD 4.7 degrees C) nasopharyngeally measured temperature respectively. Subsequently tè patients were rewarmed until normal body temperature was reached again. There was a clear influence of body temperature on the amplitudes and reproducibilities of the TEOAE. The relationship of temperature and amplitude or reproducibility during the cooling phase was significantly different from that during rewarming. No TEOAE were measurable during cooling at a mean temperature lower than 33.41 degrees C (SD 2.04 degrees C) vesical temperature and 30.16 degrees C (SD 3.0 degrees C) nasopharyngeal temperature respectively. During rewarming the echoes became recognizable again at a mean temperature of 28.75 degrees C (SD 3.38 degrees C) vesical temperature and 27.49 degrees C (SD 2.99 degrees C) nasopharyngeal temperature. These results suggest a hysteresis in the relationship between the amplitude of TEOAE and temperature, similar to the well-established relationship between evoked potentials and temperature.</p>","PeriodicalId":75616,"journal":{"name":"British journal of audiology","volume":"32 6","pages":"387-98"},"PeriodicalIF":0.0000,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/03005364000000090","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British journal of audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/03005364000000090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

Thirty patients undergoing open heart surgery under induced hypothermia had transient evoked otoacoustic emissions (TEOAE) recorded during cooling to 26.07 degrees C (standard deviation (SD) 4.25 degrees C) vesically measured temperature and 24.86 degrees C (SD 4.7 degrees C) nasopharyngeally measured temperature respectively. Subsequently tè patients were rewarmed until normal body temperature was reached again. There was a clear influence of body temperature on the amplitudes and reproducibilities of the TEOAE. The relationship of temperature and amplitude or reproducibility during the cooling phase was significantly different from that during rewarming. No TEOAE were measurable during cooling at a mean temperature lower than 33.41 degrees C (SD 2.04 degrees C) vesical temperature and 30.16 degrees C (SD 3.0 degrees C) nasopharyngeal temperature respectively. During rewarming the echoes became recognizable again at a mean temperature of 28.75 degrees C (SD 3.38 degrees C) vesical temperature and 27.49 degrees C (SD 2.99 degrees C) nasopharyngeal temperature. These results suggest a hysteresis in the relationship between the amplitude of TEOAE and temperature, similar to the well-established relationship between evoked potentials and temperature.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
体温对瞬态诱发耳声发射的影响。
30例在体外低温条件下接受心脏直视手术的患者,分别在冷却至26.07℃(标准差4.25℃)的膀胱测量温度和24.86℃(标准差4.7℃)的鼻咽测量温度时,记录了瞬时诱发耳声发射(TEOAE)。随后tè患者被重新加热,直到再次达到正常体温。体温对TEOAE的振幅和再现性有明显的影响。冷却阶段温度与振幅或再现性的关系与复温阶段有显著差异。在平均温度低于33.41℃(SD 2.04℃)的膀胱温度和30.16℃(SD 3.0℃)的鼻咽温度下冷却时,未检测到TEOAE。在复温过程中,回声在膀胱温度28.75℃(SD 3.38℃)和鼻咽温度27.49℃(SD 2.99℃)的平均温度下再次被识别出来。这些结果表明TEOAE振幅与温度之间的关系存在滞后性,类似于诱发电位与温度之间的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effects of sample size on the reliability of noise floor and DPOAE. Audiometer calibration: interpreting and applying the standards. Assessment of aided ABR thresholds before cochlear implantation. Community-based validation of the McCormick Toy Test. Audit of 5-year post-implantation routine integrity tests performed on paediatric cochlear implantees.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1