Bioabsorbable fixation in the treatment of proximal tibial osteotomies and fractures. A clinical study.

Annales chirurgiae et gynaecologiae Pub Date : 1999-01-01
P Tuompo, E Partio, P Rokkanen
{"title":"Bioabsorbable fixation in the treatment of proximal tibial osteotomies and fractures. A clinical study.","authors":"P Tuompo,&nbsp;E Partio,&nbsp;P Rokkanen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>The purpose of this study was to evaluate the use of bioabsorbable implants in proximal tibia cancellous bone fixations in 28 patients.</p><p><strong>Patients and methods: </strong>The implants used were self-reinforced polyglycolide (SR-PGA) or self-reinforced polylactide (SR-PLLA) screws or rods. In six patients a high tibial osteotomy and in 16 patients a proximal tibial plateau fracture were secured with these implants (cancellous bone fixations). In addition, four anterior tibial eminence avulsion fractures and two tibial tuberosity avulsions were fixed (avulsion fractures). The average follow-up time was 3.6 years.</p><p><strong>Result and conclusions: </strong>In the cancellous bone fixations (15 patients at the follow-up) there were three excellent clinical results, five good, five moderate and two poor results; radiologically there were one excellent result, eight good, five moderate, and one poor result. In the avulsion fracture patients (four patients at the follow-up) there were two excellent and two good clinical results; radiologically all results were excellent. In four cancellous bone fixations redisplacement was noted. In all patients the functional score was 25.6/30 (Rasmussen 1973). The bioabsorbable implants can be used for fixation of proximal tibial cancellous bone osteotomies and fractures and avulsion fractures with good or moderate results.</p>","PeriodicalId":75495,"journal":{"name":"Annales chirurgiae et gynaecologiae","volume":"88 1","pages":"66-72"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales chirurgiae et gynaecologiae","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aims: The purpose of this study was to evaluate the use of bioabsorbable implants in proximal tibia cancellous bone fixations in 28 patients.

Patients and methods: The implants used were self-reinforced polyglycolide (SR-PGA) or self-reinforced polylactide (SR-PLLA) screws or rods. In six patients a high tibial osteotomy and in 16 patients a proximal tibial plateau fracture were secured with these implants (cancellous bone fixations). In addition, four anterior tibial eminence avulsion fractures and two tibial tuberosity avulsions were fixed (avulsion fractures). The average follow-up time was 3.6 years.

Result and conclusions: In the cancellous bone fixations (15 patients at the follow-up) there were three excellent clinical results, five good, five moderate and two poor results; radiologically there were one excellent result, eight good, five moderate, and one poor result. In the avulsion fracture patients (four patients at the follow-up) there were two excellent and two good clinical results; radiologically all results were excellent. In four cancellous bone fixations redisplacement was noted. In all patients the functional score was 25.6/30 (Rasmussen 1973). The bioabsorbable implants can be used for fixation of proximal tibial cancellous bone osteotomies and fractures and avulsion fractures with good or moderate results.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
生物可吸收内固定治疗胫骨近端截骨和骨折。临床研究。
背景和目的:本研究的目的是评估生物可吸收植入物在28例胫骨近端松质骨固定中的应用。患者和方法:种植体采用自增强聚乙二醇(SR-PGA)或自增强聚乳酸(SR-PLLA)螺钉或棒。在6例胫骨高位截骨患者和16例胫骨平台近端骨折患者使用这些植入物(松质骨固定物)进行固定。另外,4例胫骨前隆起撕脱骨折和2例胫骨粗隆撕脱骨折均被固定(撕脱骨折)。平均随访时间为3.6年。结果与结论:随访15例松质骨固定,临床疗效优3例,良5例,中5例,差2例;放射学上有1例优秀,8例良好,5例中等,1例不良。在撕脱性骨折患者中(随访4例),临床疗效优2例,良2例;放射学结果均良好。在4例松质骨固定中观察到再移位。所有患者的功能评分为25.6/30 (Rasmussen 1973)。生物可吸收植入物可用于胫骨近端松质骨截骨、骨折和撕脱性骨折的固定,效果良好或中等。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Pancreatic Lymphoma Toe-to-Hand Transfer Laparoscopic laser cholecystectomy. Surgical Treatment of Colorectal Liver Metastases Blood, sweat and tears.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1