A comparison of inter-aural attenuation with the Etymotic ER-3A insert earphone and the Telephonics TDH-39 supra-aural earphone.

K J Munro, N Agnew
{"title":"A comparison of inter-aural attenuation with the Etymotic ER-3A insert earphone and the Telephonics TDH-39 supra-aural earphone.","authors":"K J Munro,&nbsp;N Agnew","doi":"10.3109/03005369909090106","DOIUrl":null,"url":null,"abstract":"<p><p>One of the many reported advantages of the insert earphone over the supra-aural earphone is increased inter-aural attenuation (IA). Minimum values of IA determine the need for masking of the non-test ear in air-conduction audiometry. The aim of the present study was to measure inter-aural attenuation for the Etymotic Research ER-3A insert earphone (with deep and shallow insertion of the ear plug within the ear canal) and compare this with the supra-aural Telephonics TDH-39/MX41-AR earphone/cushion combination. Subjects were 18 adults ranging in age from 38 to 68 years (mean 50 years). Each subject had no hearing in one ear following translabyrinthine surgery for removal of an acoustic neuroma. The opposite ear had hearing thresholds better than 40 dB HL and an air-bone gap of less than 10 dB at any audiometric frequency. Pure tone air-conduction thresholds were obtained in the range 0.25-8 kHz. Deep insertion of the insert earphone was deemed to occur when the outside edge of the ear plug was flush with the entrance of the ear canal. Shallow insertion was deemed to occur when half of the ear plug (6 mm) was inside the entrance of the ear canal. IA was defined operationally as the difference between the good-ear and poor-ear not-masked air conduction threshold for a given audiometric frequency and earphone. The results show that the TDH-39/MX41-AR combination provides a median IA of approximately 60 dB with a lower limit of approximately 45 dB. Greater IA was obtained with the ER-3A insert earphone but this depended on the depth of insertion. With a deep insertion, the 1A values were some 15-20 dB greater than with the supra-aural earphone. Although frequency-specific IA values are provided, a simple rule of thumb is to apply masking to the non-test ear when the pure tone airconduction signal from the ER-3A insert earphone exceeds the bone conduction threshold of the non-test ear by 55 dB HL or more. If it is not possible to obtain a deep insertion depth this value should be reduced by 5 dB.</p>","PeriodicalId":75616,"journal":{"name":"British journal of audiology","volume":"33 4","pages":"259-62"},"PeriodicalIF":0.0000,"publicationDate":"1999-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/03005369909090106","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British journal of audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/03005369909090106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

One of the many reported advantages of the insert earphone over the supra-aural earphone is increased inter-aural attenuation (IA). Minimum values of IA determine the need for masking of the non-test ear in air-conduction audiometry. The aim of the present study was to measure inter-aural attenuation for the Etymotic Research ER-3A insert earphone (with deep and shallow insertion of the ear plug within the ear canal) and compare this with the supra-aural Telephonics TDH-39/MX41-AR earphone/cushion combination. Subjects were 18 adults ranging in age from 38 to 68 years (mean 50 years). Each subject had no hearing in one ear following translabyrinthine surgery for removal of an acoustic neuroma. The opposite ear had hearing thresholds better than 40 dB HL and an air-bone gap of less than 10 dB at any audiometric frequency. Pure tone air-conduction thresholds were obtained in the range 0.25-8 kHz. Deep insertion of the insert earphone was deemed to occur when the outside edge of the ear plug was flush with the entrance of the ear canal. Shallow insertion was deemed to occur when half of the ear plug (6 mm) was inside the entrance of the ear canal. IA was defined operationally as the difference between the good-ear and poor-ear not-masked air conduction threshold for a given audiometric frequency and earphone. The results show that the TDH-39/MX41-AR combination provides a median IA of approximately 60 dB with a lower limit of approximately 45 dB. Greater IA was obtained with the ER-3A insert earphone but this depended on the depth of insertion. With a deep insertion, the 1A values were some 15-20 dB greater than with the supra-aural earphone. Although frequency-specific IA values are provided, a simple rule of thumb is to apply masking to the non-test ear when the pure tone airconduction signal from the ER-3A insert earphone exceeds the bone conduction threshold of the non-test ear by 55 dB HL or more. If it is not possible to obtain a deep insertion depth this value should be reduced by 5 dB.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Etymotic ER-3A插入式耳机和Telephonics TDH-39超音耳机的耳间衰减比较。
据报道,插入式耳机优于超耳耳机的众多优点之一是增加了耳间衰减(IA)。IA的最小值决定了在空气传导测听中需要屏蔽非测试耳。本研究的目的是测量Etymotic Research ER-3A插入式耳机(耳塞在耳道内深插入和浅插入)的耳间衰减,并将其与超耳Telephonics TDH-39/MX41-AR耳机/垫组合进行比较。研究对象为18名成人,年龄从38岁到68岁不等(平均50岁)。每位受试者在经迷路切除听神经瘤手术后均有一只耳朵丧失听力。在任何听力学频率下,对耳的听力阈值均大于40 dB HL,气骨间隙小于10 dB。在0.25-8 kHz范围内获得了纯音空气传导阈值。当耳塞外缘与耳道入口齐平时,即视为插入式耳机深度插入。当耳塞的一半(6mm)在耳道入口内时,认为发生浅插入。IA在操作上被定义为给定听力频率和耳机的好耳和差耳不掩盖空气传导阈值之间的差异。结果表明,TDH-39/MX41-AR组合提供的IA中位数约为60 dB,下限约为45 dB。使用ER-3A插入式耳机可获得更大的IA,但这取决于插入深度。深插入时,1A值比超听觉耳机大15-20 dB。虽然提供了特定频率的IA值,但一个简单的经验法则是,当来自ER-3A插入式耳机的纯音空气传导信号超过非测试耳的骨传导阈值55 dB HL或更多时,对非测试耳进行屏蔽。如果无法获得深插入深度,则应将该值降低5 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effects of sample size on the reliability of noise floor and DPOAE. Audiometer calibration: interpreting and applying the standards. Assessment of aided ABR thresholds before cochlear implantation. Community-based validation of the McCormick Toy Test. Audit of 5-year post-implantation routine integrity tests performed on paediatric cochlear implantees.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1