The influence of hydroxyapatite granules on the healing of a segmental defect filled with autologous bone marrow.

Annales chirurgiae et gynaecologiae Pub Date : 1999-01-01
B Wippermann, C Donow, H E Schratt, F C den Boer, T Blokhuis, P Patka
{"title":"The influence of hydroxyapatite granules on the healing of a segmental defect filled with autologous bone marrow.","authors":"B Wippermann,&nbsp;C Donow,&nbsp;H E Schratt,&nbsp;F C den Boer,&nbsp;T Blokhuis,&nbsp;P Patka","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Hydroxyapatite(HA) ceramics are frequently used as a bone graft substitutes for the filling of bony defects. The addition of autologous bone marrow to HA ceramics does improve defect healing. There is conflicting evidence in the literature whether autologous bone marrow transplantation alone is as effective as the combination of HA ceramics and bone marrow combined. It was the purpose of this study to identify the role of additional HA ceramic granules on the healing of a sheep tibia segmental defect filled with autologous bone marrow. After permission of the local animal rights committee was obtained, a 3 cm segmental defect in the midshaft of 31 adult sheep was stabilized with an unreamed tibia nail. The animals were divided into 4 groups according to the mode of defect filling: HA plus autologous bone marrow (HA + MAR) (n = 8), autologous bone marrow (MAR) (n = 9), empty defect (DEF) (n = 6), cancellous bone graft (CAN) (n = 8). After three months follow up animals were sacrificed and analysed for the key parameters of union and maximum torque at failure. One nonunion was present in each of the HA + MAR, MAR, and CAN groups. Four of the six animals in the DEF group developed a nonunion. Maximum torque at failure was reported as percentage of the intact contralateral tibia: HA + MAR 39% +/- 24%, MAR 26% +/- 17%, DEF 22% +/- 13%, CAN 41% +/- 20%. The difference between the groups was statistically significant, but appeared to be relevant. We conclude from our data, that HA ceramics do improve healing of a segmental defect in the sheep tibia filled with autologous bone marrow. The results of this combination are comparable to cancellous autograft.</p>","PeriodicalId":75495,"journal":{"name":"Annales chirurgiae et gynaecologiae","volume":"88 3","pages":"194-7"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales chirurgiae et gynaecologiae","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Hydroxyapatite(HA) ceramics are frequently used as a bone graft substitutes for the filling of bony defects. The addition of autologous bone marrow to HA ceramics does improve defect healing. There is conflicting evidence in the literature whether autologous bone marrow transplantation alone is as effective as the combination of HA ceramics and bone marrow combined. It was the purpose of this study to identify the role of additional HA ceramic granules on the healing of a sheep tibia segmental defect filled with autologous bone marrow. After permission of the local animal rights committee was obtained, a 3 cm segmental defect in the midshaft of 31 adult sheep was stabilized with an unreamed tibia nail. The animals were divided into 4 groups according to the mode of defect filling: HA plus autologous bone marrow (HA + MAR) (n = 8), autologous bone marrow (MAR) (n = 9), empty defect (DEF) (n = 6), cancellous bone graft (CAN) (n = 8). After three months follow up animals were sacrificed and analysed for the key parameters of union and maximum torque at failure. One nonunion was present in each of the HA + MAR, MAR, and CAN groups. Four of the six animals in the DEF group developed a nonunion. Maximum torque at failure was reported as percentage of the intact contralateral tibia: HA + MAR 39% +/- 24%, MAR 26% +/- 17%, DEF 22% +/- 13%, CAN 41% +/- 20%. The difference between the groups was statistically significant, but appeared to be relevant. We conclude from our data, that HA ceramics do improve healing of a segmental defect in the sheep tibia filled with autologous bone marrow. The results of this combination are comparable to cancellous autograft.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
羟基磷灰石颗粒对自体骨髓缺损愈合的影响。
羟基磷灰石(HA)陶瓷经常被用作骨移植替代物来填补骨缺损。在透明质酸陶瓷中加入自体骨髓确实能改善缺陷愈合。单独自体骨髓移植是否与HA陶瓷与骨髓联合治疗一样有效,文献中存在相互矛盾的证据。本研究的目的是确定额外的透明质酸陶瓷颗粒在自体骨髓填充绵羊胫骨节段缺损愈合中的作用。在获得当地动物权利委员会的许可后,用一枚未扩孔的胫骨钉固定了31只成年羊中轴3厘米的节段性缺损。按缺损填充方式分为HA +自体骨髓(HA + MAR)组(n = 8)、自体骨髓(MAR)组(n = 9)、空缺损(DEF)组(n = 6)、松质骨移植(CAN)组(n = 8)。随访3个月后处死动物,分析愈合及失效时最大扭矩的关键参数。HA + MAR、MAR和CAN组各出现1例骨不连。DEF组的6只动物中有4只出现了骨不连。失败时的最大扭矩为完整对侧胫骨的百分比:HA + MAR 39% +/- 24%, MAR 26% +/- 17%, DEF 22% +/- 13%, CAN 41% +/- 20%。两组之间的差异在统计学上是显著的,但似乎是相关的。我们从我们的数据中得出结论,透明质酸陶瓷确实改善了自体骨髓填充的羊胫骨节段性缺损的愈合。这种组合的结果与自体松质骨移植相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Pancreatic Lymphoma Toe-to-Hand Transfer Laparoscopic laser cholecystectomy. Surgical Treatment of Colorectal Liver Metastases Blood, sweat and tears.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1