Influence of the sampling technique on the measurement of peritoneal fibrinolytic activity.

J Neudecker, T Junghans, S Ziemer, W Raue, W Schwenk
{"title":"Influence of the sampling technique on the measurement of peritoneal fibrinolytic activity.","authors":"J Neudecker,&nbsp;T Junghans,&nbsp;S Ziemer,&nbsp;W Raue,&nbsp;W Schwenk","doi":"10.1080/11024150201680012","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To establish the influence of the peritoneal sampling technique on the measurement of fibrinolytic capacity.</p><p><strong>Design: </strong>Clinical study.</p><p><strong>Setting: </strong>University hospital, Germany.</p><p><strong>Subjects: </strong>40 peritoneal biopsy specimens were taken from 10 patients who were having elective colorectal resections.</p><p><strong>Interventions: </strong>Peritoneal biopsy specimens were taken either with a biopsy punch (n = 20) or manually with forceps and scissors (n = 20).</p><p><strong>Main outcome measures: </strong>Extent of agreement in fibrinolytic activities between specimens taken with biopsy punch and manually. Major endpoint-peritoneal tissue plasminogen activator (t-PA) activity. Minor endpoints-peritoneal tissue plasminogen activator concentration, and concentration and activity of plasminogen activator inhibitior type 1 (PAT-1).</p><p><strong>Results: </strong>Intra-assay agreement and the extent of agreement between the groups were evaluated by the method of Bland and Altman. Correlation of repeated measurements of t-PA and PAI-1 concentrations and activities from the same sample using the same ELISA kit was high (r = 0.93-0.99, p < 0.01). t-PA activities and concentrations between the groups correlated poorly (r= 0.60 and 0.66, p < 0.01) while no correlation at all was seen for PAI-1 concentration and activity between the groups (r = 0.6 and 0.1, p = 0.2 and 0.9). The mean differences between the groups ranged from -27% to -4.8%.</p><p><strong>Conclusion: </strong>The sampling technique considerably affects the measurement of peritoneal fibrinolytic activity.</p>","PeriodicalId":22411,"journal":{"name":"The European journal of surgery = Acta chirurgica","volume":"168 11","pages":"635-40"},"PeriodicalIF":0.0000,"publicationDate":"2002-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The European journal of surgery = Acta chirurgica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/11024150201680012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Objective: To establish the influence of the peritoneal sampling technique on the measurement of fibrinolytic capacity.

Design: Clinical study.

Setting: University hospital, Germany.

Subjects: 40 peritoneal biopsy specimens were taken from 10 patients who were having elective colorectal resections.

Interventions: Peritoneal biopsy specimens were taken either with a biopsy punch (n = 20) or manually with forceps and scissors (n = 20).

Main outcome measures: Extent of agreement in fibrinolytic activities between specimens taken with biopsy punch and manually. Major endpoint-peritoneal tissue plasminogen activator (t-PA) activity. Minor endpoints-peritoneal tissue plasminogen activator concentration, and concentration and activity of plasminogen activator inhibitior type 1 (PAT-1).

Results: Intra-assay agreement and the extent of agreement between the groups were evaluated by the method of Bland and Altman. Correlation of repeated measurements of t-PA and PAI-1 concentrations and activities from the same sample using the same ELISA kit was high (r = 0.93-0.99, p < 0.01). t-PA activities and concentrations between the groups correlated poorly (r= 0.60 and 0.66, p < 0.01) while no correlation at all was seen for PAI-1 concentration and activity between the groups (r = 0.6 and 0.1, p = 0.2 and 0.9). The mean differences between the groups ranged from -27% to -4.8%.

Conclusion: The sampling technique considerably affects the measurement of peritoneal fibrinolytic activity.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
取样技术对腹膜纤溶活性测定的影响。
目的:探讨腹膜取样技术对测定纤溶能力的影响。设计:临床研究。地点:德国大学医院。研究对象:从10例择期结肠切除术患者中取出40例腹膜活检标本。干预措施:采用活检打孔机(n = 20)或手工用镊子和剪刀(n = 20)采集腹膜活检标本。主要结果测量:活检打孔法和手工法取样的纤维蛋白溶解活性的一致程度。主要终点:腹膜组织纤溶酶原激活物(t-PA)活性。次要终点-腹膜组织纤溶酶原激活剂浓度,以及1型纤溶酶原激活剂抑制(PAT-1)的浓度和活性。结果:采用Bland和Altman法评价组内一致性和组间一致性程度。使用同一ELISA试剂盒对同一样品重复测定t-PA和PAI-1浓度与活性的相关性高(r = 0.93-0.99, p < 0.01)。t-PA活性和浓度组间相关性较差(r= 0.60和0.66,p < 0.01), PAI-1浓度和活性组间无相关性(r= 0.6和0.1,p = 0.2和0.9)。两组之间的平均差异在-27%到-4.8%之间。结论:取样技术对腹膜纤溶活性测定有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Influence of surgeon's volume on early outcome after total gastrectomy. Prospective evaluation of laparoscopic and open 360 degree fundoplication in mild and severe gastro-oesophageal reflux disease. Factors that affect the variability in heart rate during endoscopic retrograde cholangiopancreatography. Risk factors for severe postoperative hypocalcaemia after operations for primary hyperparathyroidism. Effects of the tyrosine kinase inhibitor tyrphostin AG 556 on acute necrotising pancreatitis in rats.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1