[Morphologic and hydrodynamic characteristics of bovine jugular venous conduit with valves].

Zhong-shi Wu, Jing-chao Zhang, Duan Cheng
{"title":"[Morphologic and hydrodynamic characteristics of bovine jugular venous conduit with valves].","authors":"Zhong-shi Wu,&nbsp;Jing-chao Zhang,&nbsp;Duan Cheng","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To determine the morphologic and hydrodynamic characteristics of bovine jugular venous conduit with valves.</p><p><strong>Methods: </strong>Fresh bovine jugular veins with a retained native valve procured from a slaughterhouse were used as raw material to fabricate the valved conduits. The hydrodynamic performance of fresh and glutaraldehyde fixed bovine jugular vein conduits with valves was investigated in an experimental flow equipment that provided a constant pressure. The perfusion flow quantity through the conduits was measured under the antegrade (from the distal end to the proximal end) and retograde (from the proximal to the distal end) perfusion. The parameters of the valves in these bovine jugular venous conduits were also measured.</p><p><strong>Results: </strong>There were 2-3 group valves in the bovine jugular venous conduit, with 3 or 2 valves in each group. The degrees of the leaflet development in different valves were different in the same conduit. The location of well-developed valves was interspersed. The anti-reflow ability of valves was positively correlated to the ratio between the leaflet height and valve sinus height (r = 0.709, P < 0.001). The percentage of retrograde and antegrade perfusion flow quantity after the glutaraldehyde treatment significantly increased than that before the glutaraldehyde treatment (P < 0.01).</p><p><strong>Conclusion: </strong>Part of the bovine jugular venous conduit has well-developed valves with strong ability against reflowing. Routine glutaraldehyde treatment obviously decreases the anti-reflow function of the conduits.</p>","PeriodicalId":13115,"journal":{"name":"Hunan yi ke da xue xue bao = Hunan yike daxue xuebao = Bulletin of Hunan Medical University","volume":"28 3","pages":"298-300"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hunan yi ke da xue xue bao = Hunan yike daxue xuebao = Bulletin of Hunan Medical University","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To determine the morphologic and hydrodynamic characteristics of bovine jugular venous conduit with valves.

Methods: Fresh bovine jugular veins with a retained native valve procured from a slaughterhouse were used as raw material to fabricate the valved conduits. The hydrodynamic performance of fresh and glutaraldehyde fixed bovine jugular vein conduits with valves was investigated in an experimental flow equipment that provided a constant pressure. The perfusion flow quantity through the conduits was measured under the antegrade (from the distal end to the proximal end) and retograde (from the proximal to the distal end) perfusion. The parameters of the valves in these bovine jugular venous conduits were also measured.

Results: There were 2-3 group valves in the bovine jugular venous conduit, with 3 or 2 valves in each group. The degrees of the leaflet development in different valves were different in the same conduit. The location of well-developed valves was interspersed. The anti-reflow ability of valves was positively correlated to the ratio between the leaflet height and valve sinus height (r = 0.709, P < 0.001). The percentage of retrograde and antegrade perfusion flow quantity after the glutaraldehyde treatment significantly increased than that before the glutaraldehyde treatment (P < 0.01).

Conclusion: Part of the bovine jugular venous conduit has well-developed valves with strong ability against reflowing. Routine glutaraldehyde treatment obviously decreases the anti-reflow function of the conduits.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
牛颈静脉带瓣膜导管的形态学和流体动力学特征。
目的:研究牛颈静脉带瓣导管的形态和流体动力学特性。方法:采用从屠宰场获得的保留天然瓣膜的新鲜牛颈静脉为原料,制作带瓣膜的导管。在恒压流动实验装置上研究了新鲜和戊二醛固定牛颈静脉带阀导管的流体力学性能。在顺行(从远端到近端)和顺行(从近端到远端)灌注下,测量通过导管的灌注流量。测量了这些牛颈静脉导管的瓣膜参数。结果:牛颈静脉导管内存在2-3组瓣膜,每组3或2个。在同一导管中,不同瓣叶的小叶发育程度不同。发育良好的阀门位置是分散的。瓣膜抗回流能力与瓣叶高度与瓣窦高度之比呈正相关(r = 0.709, P < 0.001)。戊二醛处理后逆行和顺行灌注流量的百分比显著高于戊二醛处理前(P < 0.01)。结论:部分牛颈静脉导管瓣膜发育良好,抗回流能力强。常规戊二醛处理明显降低了导管的抗回流功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Effects of nitric oxide on form-deprivation myopia in chicks]. [Percutaneous transcatheter closure for secundum atrial septal defect]. [Serum levels of antibodies for IgG, IgA, and IgM against the fungi antigen in psoriasis vulgaris]. [Etiologic analysis of 1137 inpatients of chronic renal failure]. [Clinical analysis of intrahepatic cholestasis during pregnancy in 150 patients].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1