Faecal immunochemical testing (FIT): sources of result variation based on three years of routine testing of symptomatic patients in English primary care.

IF 2.7 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY British Journal of Biomedical Science Pub Date : 2021-10-01 Epub Date: 2021-03-19 DOI:10.1080/09674845.2021.1896204
T James, B D Nicholson, R Marr, M Paddon, J E East, S Justice, J L Oke, B Shine
{"title":"Faecal immunochemical testing (FIT): sources of result variation based on three years of routine testing of symptomatic patients in English primary care.","authors":"T James,&nbsp;B D Nicholson,&nbsp;R Marr,&nbsp;M Paddon,&nbsp;J E East,&nbsp;S Justice,&nbsp;J L Oke,&nbsp;B Shine","doi":"10.1080/09674845.2021.1896204","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction</b>: We aimed to determine the analytical capabilities of a commonly used faecal immunochemical test (FIT) to detect faecal haemoglobin (Hb) in symptomatic people attending primary care in the context of the English NICE DG30 guidance.<b>Materials and Methods</b>: Data obtained from independent verification studies and clinical testing of the HM-JACKarc FIT method in routine primary care practice were analysed to derive performance characteristics.<b>Results</b>: Detection capabilities for the FIT method were 0.5 µg/g (limit of blank), 1.3 µg/g (limit of detection) and 3.0 µg/g (limit of quantitation). Of 33 non-homogenized specimens, 31 (93.9%) analysed in triplicate were consistently categorized relative to 10 µg/g, compared to all 33 (100%) homogenized specimens. Imprecision was higher (median 27.8%, (range 20.5% to 48.6%)) in non-homogenized specimens than in homogenized specimens (10.2%, (7.0 to 13.5%)). Considerable variation was observed in sequential clinical specimens from individual patients but no positive or negative trend in specimen degradation was observed over time (p = 0.26).<b>Discussion</b>: The FIT immunoassay evaluated is capable of detecting faecal Hb at concentrations well below the DG30 threshold of 10 µg/g and is suitable for application in this context. The greatest practical challenge to FIT performance is reproducible sampling, the pre-analytical step associated with most variability. Further research should focus on reducing sampling variability, particularly as post-COVID-19 guidance recommends greater FIT utilization.</p>","PeriodicalId":9236,"journal":{"name":"British Journal of Biomedical Science","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/09674845.2021.1896204","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Biomedical Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09674845.2021.1896204","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/3/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 5

Abstract

Introduction: We aimed to determine the analytical capabilities of a commonly used faecal immunochemical test (FIT) to detect faecal haemoglobin (Hb) in symptomatic people attending primary care in the context of the English NICE DG30 guidance.Materials and Methods: Data obtained from independent verification studies and clinical testing of the HM-JACKarc FIT method in routine primary care practice were analysed to derive performance characteristics.Results: Detection capabilities for the FIT method were 0.5 µg/g (limit of blank), 1.3 µg/g (limit of detection) and 3.0 µg/g (limit of quantitation). Of 33 non-homogenized specimens, 31 (93.9%) analysed in triplicate were consistently categorized relative to 10 µg/g, compared to all 33 (100%) homogenized specimens. Imprecision was higher (median 27.8%, (range 20.5% to 48.6%)) in non-homogenized specimens than in homogenized specimens (10.2%, (7.0 to 13.5%)). Considerable variation was observed in sequential clinical specimens from individual patients but no positive or negative trend in specimen degradation was observed over time (p = 0.26).Discussion: The FIT immunoassay evaluated is capable of detecting faecal Hb at concentrations well below the DG30 threshold of 10 µg/g and is suitable for application in this context. The greatest practical challenge to FIT performance is reproducible sampling, the pre-analytical step associated with most variability. Further research should focus on reducing sampling variability, particularly as post-COVID-19 guidance recommends greater FIT utilization.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
粪便免疫化学测试(FIT):基于英国初级保健症状患者三年常规测试的结果差异来源。
简介:我们的目的是确定一种常用的粪便免疫化学试验(FIT)的分析能力,以检测在英国NICE DG30指南背景下参加初级保健的有症状患者的粪便血红蛋白(Hb)。材料和方法:从独立验证研究和HM-JACKarc FIT方法在常规初级保健实践中的临床试验中获得的数据进行分析,以得出性能特征。结果:FIT方法的检测能力分别为0.5µg/g(空白限)、1.3µg/g(检测限)和3.0µg/g(定量限)。在33个未匀浆的样本中,与所有33个(100%)匀浆的样本相比,31个(93.9%)的三次分析样本的分类相对于10µg/g一致。未匀浆标本的不精确性(中位数27.8%,范围20.5%至48.6%)高于匀浆标本(10.2%,范围7.0至13.5%)。在个体患者的连续临床标本中观察到相当大的变化,但随着时间的推移,没有观察到标本降解的阳性或阴性趋势(p = 0.26)。讨论:评估的FIT免疫分析法能够检测浓度远低于DG30阈值10µg/g的粪便Hb,适合在这种情况下应用。FIT性能的最大实际挑战是可重复采样,这是与大多数可变性相关的分析前步骤。进一步的研究应侧重于减少抽样变异性,特别是在covid -19后的指南建议提高FIT利用率的情况下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
British Journal of Biomedical Science
British Journal of Biomedical Science 医学-医学实验技术
CiteScore
4.40
自引率
15.80%
发文量
29
审稿时长
>12 weeks
期刊介绍: The British Journal of Biomedical Science is committed to publishing high quality original research that represents a clear advance in the practice of biomedical science, and reviews that summarise recent advances in the field of biomedical science. The overall aim of the Journal is to provide a platform for the dissemination of new and innovative information on the diagnosis and management of disease that is valuable to the practicing laboratory scientist.
期刊最新文献
Improving Biomedical Science Literacy and Patient-Directed Knowledge of Tuberculosis (TB): A Cross-Sectional Infodemiology Study Examining Readability of Patient-Facing TB Information. Mesoporous Silica Microparticle-Protein Complexes: Effects of Protein Size and Solvent Properties on Diffusion and Loading Efficiency. Neuronal Vulnerability of the Entorhinal Cortex to Tau Pathology in Alzheimer's Disease. Evaluating Lung Changes in Long COVID: Ultra-Low-Dose vs. Standard-Dose CT Chest. Editorial: Advances in Cancer Diagnosis and Treatment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1