Faecal immunochemical testing (FIT): sources of result variation based on three years of routine testing of symptomatic patients in English primary care.
T James, B D Nicholson, R Marr, M Paddon, J E East, S Justice, J L Oke, B Shine
{"title":"Faecal immunochemical testing (FIT): sources of result variation based on three years of routine testing of symptomatic patients in English primary care.","authors":"T James, B D Nicholson, R Marr, M Paddon, J E East, S Justice, J L Oke, B Shine","doi":"10.1080/09674845.2021.1896204","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction</b>: We aimed to determine the analytical capabilities of a commonly used faecal immunochemical test (FIT) to detect faecal haemoglobin (Hb) in symptomatic people attending primary care in the context of the English NICE DG30 guidance.<b>Materials and Methods</b>: Data obtained from independent verification studies and clinical testing of the HM-JACKarc FIT method in routine primary care practice were analysed to derive performance characteristics.<b>Results</b>: Detection capabilities for the FIT method were 0.5 µg/g (limit of blank), 1.3 µg/g (limit of detection) and 3.0 µg/g (limit of quantitation). Of 33 non-homogenized specimens, 31 (93.9%) analysed in triplicate were consistently categorized relative to 10 µg/g, compared to all 33 (100%) homogenized specimens. Imprecision was higher (median 27.8%, (range 20.5% to 48.6%)) in non-homogenized specimens than in homogenized specimens (10.2%, (7.0 to 13.5%)). Considerable variation was observed in sequential clinical specimens from individual patients but no positive or negative trend in specimen degradation was observed over time (p = 0.26).<b>Discussion</b>: The FIT immunoassay evaluated is capable of detecting faecal Hb at concentrations well below the DG30 threshold of 10 µg/g and is suitable for application in this context. The greatest practical challenge to FIT performance is reproducible sampling, the pre-analytical step associated with most variability. Further research should focus on reducing sampling variability, particularly as post-COVID-19 guidance recommends greater FIT utilization.</p>","PeriodicalId":9236,"journal":{"name":"British Journal of Biomedical Science","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/09674845.2021.1896204","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Biomedical Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09674845.2021.1896204","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/3/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 5
Abstract
Introduction: We aimed to determine the analytical capabilities of a commonly used faecal immunochemical test (FIT) to detect faecal haemoglobin (Hb) in symptomatic people attending primary care in the context of the English NICE DG30 guidance.Materials and Methods: Data obtained from independent verification studies and clinical testing of the HM-JACKarc FIT method in routine primary care practice were analysed to derive performance characteristics.Results: Detection capabilities for the FIT method were 0.5 µg/g (limit of blank), 1.3 µg/g (limit of detection) and 3.0 µg/g (limit of quantitation). Of 33 non-homogenized specimens, 31 (93.9%) analysed in triplicate were consistently categorized relative to 10 µg/g, compared to all 33 (100%) homogenized specimens. Imprecision was higher (median 27.8%, (range 20.5% to 48.6%)) in non-homogenized specimens than in homogenized specimens (10.2%, (7.0 to 13.5%)). Considerable variation was observed in sequential clinical specimens from individual patients but no positive or negative trend in specimen degradation was observed over time (p = 0.26).Discussion: The FIT immunoassay evaluated is capable of detecting faecal Hb at concentrations well below the DG30 threshold of 10 µg/g and is suitable for application in this context. The greatest practical challenge to FIT performance is reproducible sampling, the pre-analytical step associated with most variability. Further research should focus on reducing sampling variability, particularly as post-COVID-19 guidance recommends greater FIT utilization.
期刊介绍:
The British Journal of Biomedical Science is committed to publishing high quality original research that represents a clear advance in the practice of biomedical science, and reviews that summarise recent advances in the field of biomedical science. The overall aim of the Journal is to provide a platform for the dissemination of new and innovative information on the diagnosis and management of disease that is valuable to the practicing laboratory scientist.