Improving Eye-Computer Interaction Interface Design: Ergonomic Investigations of the Optimum Target Size and Gaze-triggering Dwell Time.

IF 1.3 4区 心理学 Q3 OPHTHALMOLOGY Journal of Eye Movement Research Pub Date : 2020-09-25 DOI:10.16910/jemr.12.3.8
Ya-Feng Niu, Yue Gao, Ya-Ting Zhang, Cheng-Qi Xue, Li-Xin Yang
{"title":"Improving Eye-Computer Interaction Interface Design: Ergonomic Investigations of the Optimum Target Size and Gaze-triggering Dwell Time.","authors":"Ya-Feng Niu,&nbsp;Yue Gao,&nbsp;Ya-Ting Zhang,&nbsp;Cheng-Qi Xue,&nbsp;Li-Xin Yang","doi":"10.16910/jemr.12.3.8","DOIUrl":null,"url":null,"abstract":"<p><p>Interactive feedback of interface elements and low level of spatial accuracy are two main key points for the interaction research in the Eye-computer interaction system. This study tried to solve these two problems from the perspective of human-computer interactions and ergonomics. Two experiments were conducted to explore the optimum target size and gaze-triggering dwell time of the eye-computer interaction (ECI) system. Experimental Series 1 was used as the pre-experiment to identify the size that has a greater task completion rate. Experimental Series 2 was used as the main experiment to investigate the optimum gaze-triggering dwell time by using a comprehensive evaluation of the task completion rate, reaction time, and NASA-TLX (Task Load Index). In Experimental Series 1, the optimal element size was determined to be 256 × 256p x 2. The conclusion of Experimental Series 2 was that when the dwell time is set to 600 ms, the efficiency of the interface is the highest, and the task load of subjects is minimal as well. Finally, the results of Experiment Series 1 and 2 have positive effects on improving the usability of the interface. The optimal control size and the optimal dwell time obtained from the experiments have certain reference and application value for interface design and software development of the ECI system.</p>","PeriodicalId":15813,"journal":{"name":"Journal of Eye Movement Research","volume":"12 3","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2020-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7880147/pdf/","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Eye Movement Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.16910/jemr.12.3.8","RegionNum":4,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 8

Abstract

Interactive feedback of interface elements and low level of spatial accuracy are two main key points for the interaction research in the Eye-computer interaction system. This study tried to solve these two problems from the perspective of human-computer interactions and ergonomics. Two experiments were conducted to explore the optimum target size and gaze-triggering dwell time of the eye-computer interaction (ECI) system. Experimental Series 1 was used as the pre-experiment to identify the size that has a greater task completion rate. Experimental Series 2 was used as the main experiment to investigate the optimum gaze-triggering dwell time by using a comprehensive evaluation of the task completion rate, reaction time, and NASA-TLX (Task Load Index). In Experimental Series 1, the optimal element size was determined to be 256 × 256p x 2. The conclusion of Experimental Series 2 was that when the dwell time is set to 600 ms, the efficiency of the interface is the highest, and the task load of subjects is minimal as well. Finally, the results of Experiment Series 1 and 2 have positive effects on improving the usability of the interface. The optimal control size and the optimal dwell time obtained from the experiments have certain reference and application value for interface design and software development of the ECI system.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
改进眼-机交互界面设计:最佳目标尺寸和凝视触发停留时间的人机工程学研究。
界面元素的交互反馈和空间精度不高是眼-机交互系统中交互研究的两个主要问题。本研究试图从人机交互和人机工程学的角度来解决这两个问题。通过两个实验探讨了眼-机交互(ECI)系统的最佳靶尺寸和注视触发停留时间。实验系列1作为预实验,确定任务完成率较高的尺寸。以实验系列2为主要实验,采用任务完成率、反应时间和NASA-TLX (task Load Index,任务负荷指数)作为综合评价指标,探讨最佳凝视触发停留时间。在实验系列1中,确定最佳元素尺寸为256 × 256p × 2。实验系列2的结论是,当停留时间设置为600 ms时,界面效率最高,受试者的任务负荷最小。最后,实验系列1和2的结果对提高界面的可用性有积极的作用。实验得到的最优控制尺寸和最优停留时间对ECI系统的界面设计和软件开发具有一定的参考和应用价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.90
自引率
33.30%
发文量
10
审稿时长
10 weeks
期刊介绍: The Journal of Eye Movement Research is an open-access, peer-reviewed scientific periodical devoted to all aspects of oculomotor functioning including methodology of eye recording, neurophysiological and cognitive models, attention, reading, as well as applications in neurology, ergonomy, media research and other areas,
期刊最新文献
Intelligent Evaluation Method for Design Education and Comparison Research between visualizing Heat-Maps of Class Activation and Eye-Movement. The level of skills involved in an observation-based gait analysis. Effect of Action Video Games in Eye Movement Behavior: A Systematic Review. Persistence of primitive reflexes associated with asymmetries in fixation and ocular motility values. The Observer's Lens: The Impact of Personality Traits and Gaze on Facial Impression Inferences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1