Middle-ear transmission in humans: wide-band, not frequency-tuned?

Mario A Ruggero, Andrei N Temchin
{"title":"Middle-ear transmission in humans: wide-band, not frequency-tuned?","authors":"Mario A Ruggero,&nbsp;Andrei N Temchin","doi":"10.1121/1.1566924","DOIUrl":null,"url":null,"abstract":"<p><p>Postmortem and in vivo vibration responses to sound of the stapes and the umbo of human ears are surveyed. The magnitudes of umbo velocity responses recorded postmortem decay between 1 and 5 or 10 kHz at rates between 0 and -3 dB/octave. In contrast, the magnitudes of in vivo umbo vibration are relatively invariant over a wide frequency range, amply exceeding the bandwidth of the audiogram according to one report. Similarly, most studies of postmortem stapes vibration report velocities tuned to about 1 kHz, with magnitudes that decay at a rate of about -6 dB/octave at higher frequencies. In contrast, in vivo stapes responses are apparently only mildly tuned. We conjecture that the bandwidth of stapes vibration velocity in humans will eventually be shown to exceed the bandwidth of the audiogram, in line with findings in other amniotic vertebrates.</p>","PeriodicalId":87384,"journal":{"name":"Acoustics research letters online : ARLO","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1121/1.1566924","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acoustics research letters online : ARLO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1121/1.1566924","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

Abstract

Postmortem and in vivo vibration responses to sound of the stapes and the umbo of human ears are surveyed. The magnitudes of umbo velocity responses recorded postmortem decay between 1 and 5 or 10 kHz at rates between 0 and -3 dB/octave. In contrast, the magnitudes of in vivo umbo vibration are relatively invariant over a wide frequency range, amply exceeding the bandwidth of the audiogram according to one report. Similarly, most studies of postmortem stapes vibration report velocities tuned to about 1 kHz, with magnitudes that decay at a rate of about -6 dB/octave at higher frequencies. In contrast, in vivo stapes responses are apparently only mildly tuned. We conjecture that the bandwidth of stapes vibration velocity in humans will eventually be shown to exceed the bandwidth of the audiogram, in line with findings in other amniotic vertebrates.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人类中耳传播:宽带,非频率调谐?
研究了人耳镫骨和镫骨在死后和体内对声音的振动响应。死后记录的umbo速度响应的幅度在1到5或10 kHz之间衰减,速率在0到-3 dB/倍频之间。相比之下,根据一份报告,体内振动的幅度在很宽的频率范围内相对不变,远远超过听力图的带宽。类似地,大多数关于死后镫骨振动的研究报告称,其振动速度约为1khz,在更高的频率下,其振幅衰减速度约为- 6db / ocave。相比之下,在体内镫骨的反应显然只有轻微的调整。我们推测,人类镫骨振动速度的带宽最终将超过听音图的带宽,这与其他羊膜脊椎动物的发现一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Cavitation selectively reduces the negative-pressure phase of lithotripter shock pulses. A method of flight path and chirp pattern reconstruction for multiple flying bats A shallow-water ocean acoustics inverse problem Fluctuations in sound transmission through sound speed profiles that are periodic in range and geotime Matched field range and depth resolution in range-dependent waveguides
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1