Rakesh Kumar Mahajan, Pallavi Sood, Mohinder Pal Mahajan, Alka Marwaha
{"title":"Mercury(II) Ion-Selective Electrodes Based on Heterocyclic Systems","authors":"Rakesh Kumar Mahajan, Pallavi Sood, Mohinder Pal Mahajan, Alka Marwaha","doi":"10.1002/adic.200790080","DOIUrl":null,"url":null,"abstract":"<p>Mercury ion-selective electrodes (ISEs) were prepared with a polymeric membrane based on heterocyclic systems: 2-methylsulfanyl-4-(4-nitro-phenyl)-1-p-tolyl-1H-imidazole <b>(I)</b> and 2,4-diphenyl-1-p-tolyl-1H-imidazole <b>(II)</b> as the ionophores. Several ISEs were conditioned and tested for the selection of common ions. The electrodes based on these ionophores showed a good potentiometric response for Hg<sup>2+</sup> ions over a wide concentration range of 5.0×10<sup>-5</sup>-1.0×10<sup>-1</sup>M with near-Nernstian slopes. Stable potentiometric signals were obtained within a short time period of 20 s. The detection limits, the working pH range of the electrodes were 1.0×10<sup>-5</sup> M and 1.6-4.4 respectively. The electrodes showed better selectivity for Hg<sup>2+</sup> ions over many of the alkali, alkaline-earth and heavy metal ions. Also sharp end points were obtained when these sensors were used as indicator electrodes for the potentiometric titration of Hg<sup>2+</sup> ions with iodide ions.</p>","PeriodicalId":8193,"journal":{"name":"Annali di chimica","volume":"97 9","pages":"959-970"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/adic.200790080","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di chimica","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
Mercury ion-selective electrodes (ISEs) were prepared with a polymeric membrane based on heterocyclic systems: 2-methylsulfanyl-4-(4-nitro-phenyl)-1-p-tolyl-1H-imidazole (I) and 2,4-diphenyl-1-p-tolyl-1H-imidazole (II) as the ionophores. Several ISEs were conditioned and tested for the selection of common ions. The electrodes based on these ionophores showed a good potentiometric response for Hg2+ ions over a wide concentration range of 5.0×10-5-1.0×10-1M with near-Nernstian slopes. Stable potentiometric signals were obtained within a short time period of 20 s. The detection limits, the working pH range of the electrodes were 1.0×10-5 M and 1.6-4.4 respectively. The electrodes showed better selectivity for Hg2+ ions over many of the alkali, alkaline-earth and heavy metal ions. Also sharp end points were obtained when these sensors were used as indicator electrodes for the potentiometric titration of Hg2+ ions with iodide ions.