PVC Matrix Membrane Sensor for Potentiometric Determination of Triphenyltetrazolium Chloride and Ascorbic Acid

Gamal Abdel-Hafiz Mostafa
{"title":"PVC Matrix Membrane Sensor for Potentiometric Determination of Triphenyltetrazolium Chloride and Ascorbic Acid","authors":"Gamal Abdel-Hafiz Mostafa","doi":"10.1002/adic.200790110","DOIUrl":null,"url":null,"abstract":"<p>The construction and performance characteristic of a potentiometric PVC membrane sensor for the determination of triphenyltetrazolium chloride (TPTCl) is described. The sensor is based on the use of triphenyltetrazolium (TPT)-tetraphenylborate (TPB) ion pair as ion exchange sites in PVC matrix in presence of dioctylphathalte as plasticizer. The TPT membrane sensor shows a stable, near-Nernestian response for 6×10<sup>-6</sup> - 1×10<sup>-2</sup> M TPTCl at 25 °C over the pH range 3-10 with cationic slope of 57.0 ± 0.5. The lower detection limit is 4×0<sup>-6</sup>M and the response time is 10-30 sec. Selectivity coefficients for TPTCl relative to a number of different cations and anions were investigated, which there is negligible interferences. However, iodide, bromide and thiocyanate were interfering. The determination of 2.0- 3340.0 μg/ml of TPTCl in aqueous solutions shows an average recovery of 98.5 % and a mean relative standard deviation of 1.9 at 160μg/ml. The proposed method has been used for indirect potentiometric determination of ascorbic acid in its pharmaceutical formulations which are comparable favorably with those of British pharmacopoeia method. Precipitation titrations involving TPTCl as titrant are monitored with NaTPB using the proposed membrane sensor; the inflection break is about 300 mV.</p>","PeriodicalId":8193,"journal":{"name":"Annali di chimica","volume":"97 11-12","pages":"1247-1256"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/adic.200790110","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di chimica","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790110","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The construction and performance characteristic of a potentiometric PVC membrane sensor for the determination of triphenyltetrazolium chloride (TPTCl) is described. The sensor is based on the use of triphenyltetrazolium (TPT)-tetraphenylborate (TPB) ion pair as ion exchange sites in PVC matrix in presence of dioctylphathalte as plasticizer. The TPT membrane sensor shows a stable, near-Nernestian response for 6×10-6 - 1×10-2 M TPTCl at 25 °C over the pH range 3-10 with cationic slope of 57.0 ± 0.5. The lower detection limit is 4×0-6M and the response time is 10-30 sec. Selectivity coefficients for TPTCl relative to a number of different cations and anions were investigated, which there is negligible interferences. However, iodide, bromide and thiocyanate were interfering. The determination of 2.0- 3340.0 μg/ml of TPTCl in aqueous solutions shows an average recovery of 98.5 % and a mean relative standard deviation of 1.9 at 160μg/ml. The proposed method has been used for indirect potentiometric determination of ascorbic acid in its pharmaceutical formulations which are comparable favorably with those of British pharmacopoeia method. Precipitation titrations involving TPTCl as titrant are monitored with NaTPB using the proposed membrane sensor; the inflection break is about 300 mV.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
PVC基质膜传感器电位法测定氯化三苯四唑和抗坏血酸
介绍了一种测定氯化三苯四唑(TPTCl)的电位式PVC膜传感器的结构和性能特点。该传感器是基于使用三苯基四唑(TPT)-四苯基硼酸盐(TPB)离子对作为离子交换位点,在二辛基二甲酸盐作为增塑剂存在的PVC基体中。在pH值3-10范围内,TPT膜传感器对6×10-6 - 1×10-2 M TPTCl在25°C下具有稳定的近似nerne斯蒂响应,阳离子斜率为57.0±0.5。检测下限为4×0-6M,响应时间为10-30秒。研究了TPTCl相对于多种不同阳离子和阴离子的选择性系数,干扰可以忽略不计。然而,碘化物、溴化物和硫氰酸盐有干扰作用。在160μg/ml条件下,对2.0 ~ 3340.0 μg/ml的TPTCl的平均回收率为98.5%,平均相对标准偏差为1.9。该方法已用于制剂中抗坏血酸的间接电位测定,可与英国药典方法相媲美。以TPTCl为滴定剂的沉淀滴定用所提出的膜传感器用NaTPB监测;弯折断约300毫伏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of Solid Phase Microextraction-High Performance Liquid Chromatographic Method for the Determination of Copper(II) in Environmental Samples Using Morpholine-4-Carbodithioate Flotation Separation and Flame Atomic Absorption Spectrometric Determination of Trace Amount of Lead in Some Environmental Samples Investigation of Distribution of Heavy Metals between Blood Plasma and Blood Cells Kinetic-Catalytic and Spectrophotometric Determination of Hg(II) Using its Catalytic Effect on Ligand Substitution Reaction between Hexacyanoferrate(II) and Pyrazine PVC Matrix Membrane Sensor for Potentiometric Determination of Triphenyltetrazolium Chloride and Ascorbic Acid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1