Evaluation of hardness and colour change of soft liners after accelerated ageing.

Daniela Nardi Mancuso, Marcelo Coelho Goiato, Bruna Carolina Rossatti Zuccolotti, Amália Moreno, Daniela Micheline dos Santos
{"title":"Evaluation of hardness and colour change of soft liners after accelerated ageing.","authors":"Daniela Nardi Mancuso,&nbsp;Marcelo Coelho Goiato,&nbsp;Bruna Carolina Rossatti Zuccolotti,&nbsp;Amália Moreno,&nbsp;Daniela Micheline dos Santos","doi":"10.1308/135576109788634232","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Soft liners have been developed to offer comfort to denture wearers. However, this comfort is compromised when there is a change in the properties of the material, causing colour change, solubility, absorption and hardening. These characteristics can compromise the longevity of soft liners.</p><p><strong>Aim: </strong>The aim of this in vitro study was to investigate the effect of ageing on both the hardness and colour change of two soft liners following accelerated ageing.</p><p><strong>Methods: </strong>Two denture liners, one resin based (Trusoft, Bosworth, Illinois, USA) and one silicone based (Ufi Gel P, Voco GMBH, Cuxhaven, Germany), were tested in this study for both hardness (using the Shore A scale) and colour change (using the CIE L*a*b* colour scale), initially and after 1008 hours (6 weeks) of accelerated ageing. Statistical analysis was performed using the unpaired t-test with the Welch correction.</p><p><strong>Results: </strong>These indicated that both materials increased in hardness and underwent colour change after accelerated ageing. The initial hardness of Trusoft was far lower than that of Ufi Gel P (18.2 Shore A units vs 34.8 Shore A units). However, for Trusoft the changes for both hardness (from 18.2 to 52.1 Shore A units) and colour change (16.85 on the CIE L*a*b* colour scale) were greater than those for Ufi Gel P, for which hardness changed from 34.8 to 36.5 Shore A units and the colour change was 5.19 on the CIE L*a*b* colour scale.</p><p><strong>Conclusions: </strong>Ufi Gel P underwent less hardness and colour change after accelerated ageing than Trusoft. On the other hand, the use of Trusoft may be preferable in cases where initial softness is a major consideration, such as when relining an immediate denture after implant surgery.</p>","PeriodicalId":79454,"journal":{"name":"Primary dental care : journal of the Faculty of General Dental Practitioners (UK)","volume":"16 3","pages":"127-30"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1308/135576109788634232","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Primary dental care : journal of the Faculty of General Dental Practitioners (UK)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1308/135576109788634232","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

Introduction: Soft liners have been developed to offer comfort to denture wearers. However, this comfort is compromised when there is a change in the properties of the material, causing colour change, solubility, absorption and hardening. These characteristics can compromise the longevity of soft liners.

Aim: The aim of this in vitro study was to investigate the effect of ageing on both the hardness and colour change of two soft liners following accelerated ageing.

Methods: Two denture liners, one resin based (Trusoft, Bosworth, Illinois, USA) and one silicone based (Ufi Gel P, Voco GMBH, Cuxhaven, Germany), were tested in this study for both hardness (using the Shore A scale) and colour change (using the CIE L*a*b* colour scale), initially and after 1008 hours (6 weeks) of accelerated ageing. Statistical analysis was performed using the unpaired t-test with the Welch correction.

Results: These indicated that both materials increased in hardness and underwent colour change after accelerated ageing. The initial hardness of Trusoft was far lower than that of Ufi Gel P (18.2 Shore A units vs 34.8 Shore A units). However, for Trusoft the changes for both hardness (from 18.2 to 52.1 Shore A units) and colour change (16.85 on the CIE L*a*b* colour scale) were greater than those for Ufi Gel P, for which hardness changed from 34.8 to 36.5 Shore A units and the colour change was 5.19 on the CIE L*a*b* colour scale.

Conclusions: Ufi Gel P underwent less hardness and colour change after accelerated ageing than Trusoft. On the other hand, the use of Trusoft may be preferable in cases where initial softness is a major consideration, such as when relining an immediate denture after implant surgery.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
软衬加速老化后硬度及颜色变化的评价。
介绍:软衬垫已开发提供舒适的假牙佩戴者。然而,当材料的性质发生变化时,这种舒适就会受到损害,导致颜色变化、溶解度、吸收和硬化。这些特点会影响软衬垫的使用寿命。目的:本体外研究的目的是探讨老化对加速老化后两种软衬的硬度和颜色变化的影响。方法:两种义齿衬垫,一种树脂基(Trusoft, Bosworth, Illinois, USA)和一种硅基(Ufi Gel P, Voco GMBH, Cuxhaven, Germany),在本研究中测试了硬度(使用Shore A标度)和颜色变化(使用CIE L* A *b*色标度),在1008小时(6周)加速老化后。采用Welch校正的非配对t检验进行统计分析。结果:两种材料在加速老化后硬度增加,颜色发生变化。Trusoft的初始硬度远低于Ufi Gel P(18.2邵氏A单位对34.8邵氏A单位)。然而,对于Trusoft来说,硬度(从18.2到52.1邵氏A单位)和颜色变化(在CIE L* A *b*色标上为16.85)的变化都大于Ufi Gel P,后者的硬度从34.8到36.5邵氏A单位,颜色变化在CIE L* A *b*色标上为5.19。结论:Ufi Gel P在加速老化后的硬度和颜色变化均小于Trusoft。另一方面,使用Trusoft可能更可取的情况下,最初的柔软度是一个主要的考虑因素,如当种植手术后立即修复义齿。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reflections on the Faculty of General Dental Practice (UK) at 20 years. A patient's view of dentistry 20 years ago, now, and in 20 years' time. Primary Dental Care: past, present and future. Primary dental care: time to revise the definition? Prim Dent Care 2000. 7(3):93-96. Dental specialist lists: are they necessary?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1