[Evaluation of rapid antimicrobial susceptibility test for Staphylococcus aureus by chemiluminescent assay and its application for screening of beta-lactam antibiotic induced vancomycin-resistant MRSA].

Zenzo Nagasawa, Yukari Nakashima, Megumi Oho, Kouji Kusaba, Isao Manome, Ariaki Nagayama
{"title":"[Evaluation of rapid antimicrobial susceptibility test for Staphylococcus aureus by chemiluminescent assay and its application for screening of beta-lactam antibiotic induced vancomycin-resistant MRSA].","authors":"Zenzo Nagasawa,&nbsp;Yukari Nakashima,&nbsp;Megumi Oho,&nbsp;Kouji Kusaba,&nbsp;Isao Manome,&nbsp;Ariaki Nagayama","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Minimum inhibitory concentrations (MICs) of vancomycin (VCM) and teicoplanin (TEIC) were measured using a novel susceptibility test based on the chemiluminescence assay method (CA) (Rapid-Lumi Eiken; Eiken Chemicals, Tokyo, Japan) against 84 strains of Staphylococcus aureus, consisting of 82 strains of methicillin-resistant S. aureus (MRSA) from clinical isolated, S. aureus Mu3 involving beta-lactam antibiotic induced vancomycin (VCM) resistant MRSA (BIVR) and methicillin-susceptible S. aureus ATCC 29213. The results were in good accordance with the values determined by Clinical and Laboratory Standards Institute (CLSI): i.e., 100% (84/84) of consistency for VCM and 95% (80/84) for TEIC, respectively. In addition, BIVR strains were properly estimated from the results of the CA method and using the BIVR detection method with Mu3 agar (Mu3 Agar method), even though the incubation times was very short (2-4 h). In conclusion, it was found that the new method is reliable and rapid to detect BIVR strains in clinical laboratories.</p>","PeriodicalId":74740,"journal":{"name":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","volume":"19 1-2","pages":"7-15"},"PeriodicalIF":0.0000,"publicationDate":"2008-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Minimum inhibitory concentrations (MICs) of vancomycin (VCM) and teicoplanin (TEIC) were measured using a novel susceptibility test based on the chemiluminescence assay method (CA) (Rapid-Lumi Eiken; Eiken Chemicals, Tokyo, Japan) against 84 strains of Staphylococcus aureus, consisting of 82 strains of methicillin-resistant S. aureus (MRSA) from clinical isolated, S. aureus Mu3 involving beta-lactam antibiotic induced vancomycin (VCM) resistant MRSA (BIVR) and methicillin-susceptible S. aureus ATCC 29213. The results were in good accordance with the values determined by Clinical and Laboratory Standards Institute (CLSI): i.e., 100% (84/84) of consistency for VCM and 95% (80/84) for TEIC, respectively. In addition, BIVR strains were properly estimated from the results of the CA method and using the BIVR detection method with Mu3 agar (Mu3 Agar method), even though the incubation times was very short (2-4 h). In conclusion, it was found that the new method is reliable and rapid to detect BIVR strains in clinical laboratories.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[化学发光法快速金黄色葡萄球菌药敏试验评价及其在β -内酰胺类抗生素诱导万古霉素耐药MRSA筛选中的应用]。
万古霉素(VCM)和替柯planin (TEIC)的最低抑制浓度(mic)采用一种基于化学发光测定法(CA)的新型药敏试验(快速发光Eiken;Eiken Chemicals,东京,日本)对84株金黄色葡萄球菌进行了研究,其中包括临床分离的82株耐甲氧西林金黄色葡萄球菌(MRSA),金黄色葡萄球菌Mu3涉及β -内酰胺抗生素诱导的万古霉素(VCM)耐药MRSA (BIVR)和甲氧西林敏感金黄色葡萄球菌ATCC 29213。结果与临床与实验室标准协会(CLSI)的测定值吻合良好:VCM的一致性为100% (84/84),TEIC的一致性为95%(80/84)。此外,尽管培养时间很短(2 ~ 4 h),但从CA法和Mu3琼脂BIVR检测方法(Mu3琼脂法)的结果中可以正确估计出BIVR菌株。总之,新方法在临床实验室检测BIVR菌株是可靠的、快速的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Japanese Case of COVID-19 Caused by Omicron Strain with Y453F Substitution. [Evaluation of Methicillin Resistance Determination Time for MRSA Using Fully Automated Rapid Identification Susceptibility testing system RAISAS S4]. [Evaluation of the Clinical Validity of the Clostridioides difficile Nucleic Acid Detection Kit "Smart Gene® CD ToxinB"]. [Relationship between Serotypes and Biotypes of Yersinia enterocolitica and the Names of Identified Bacteria in the Microbial Identification and Susceptibility Testing Devices]. Comparison of Microorganism Detection, Time to Positivity, and Time-Dependent Shift in Viable Bacterial Count from VersaTREK and BacT/ALERT 3D Blood Culture Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1