Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets.

Thomas W Major, Jason P Carey, David S Nobes, Paul W Major
{"title":"Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets.","authors":"Thomas W Major,&nbsp;Jason P Carey,&nbsp;David S Nobes,&nbsp;Paul W Major","doi":"10.4061/2010/781321","DOIUrl":null,"url":null,"abstract":"<p><p>In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and lines are fitted to define a trapezoidal slot shape. This investigation measures slot height at the slot's top and bottom, angles between walls, slot taper, and the linearity of each wall. Slot dimensions for 30 upper right central incisor self-ligating stainless steel brackets from three manufacturers were evaluated. Speed brackets have a slot height 2% smaller than the nominal 0.559 mm size and have a slightly convergent taper. In-Ovation brackets have a divergent taper at an average angle of 1.47 degrees. In-Ovation is closest to the nominal value of slot height at the slot base and has the smallest manufacturing tolerances. Damon Q brackets are the most rectangular in shape, with nearly 90-degree corners between the slot bottom and walls. Damon slot height is on average 3% oversized.</p>","PeriodicalId":88916,"journal":{"name":"Journal of dental biomechanics","volume":"2010 ","pages":"781321"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2958443/pdf/","citationCount":"34","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4061/2010/781321","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 34

Abstract

In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and lines are fitted to define a trapezoidal slot shape. This investigation measures slot height at the slot's top and bottom, angles between walls, slot taper, and the linearity of each wall. Slot dimensions for 30 upper right central incisor self-ligating stainless steel brackets from three manufacturers were evaluated. Speed brackets have a slot height 2% smaller than the nominal 0.559 mm size and have a slightly convergent taper. In-Ovation brackets have a divergent taper at an average angle of 1.47 degrees. In-Ovation is closest to the nominal value of slot height at the slot base and has the smallest manufacturing tolerances. Damon Q brackets are the most rectangular in shape, with nearly 90-degree corners between the slot bottom and walls. Damon slot height is on average 3% oversized.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
正畸托架制造公差及选用自结扎托架的尺寸差异。
在所有的制造过程中都有公差;然而,正畸支架制造商很少说明槽的尺寸公差。本实验提出了一种利用槽的照片分析槽外形尺寸的新方法。沿着每面墙选择五个点,并拟合线条以定义梯形槽形。该研究测量了槽顶和槽底的高度、槽壁之间的角度、槽锥度以及每个槽壁的线性度。对三家厂家生产的30个右上切牙自结扎不锈钢托槽进行了槽位尺寸评估。速度支架的槽高度比公称的0.559毫米尺寸小2%,并有一个稍微收敛的锥度。In-Ovation托架有一个分散的锥度,平均角度为1.47度。In-Ovation最接近槽底槽高度的标称值,并且具有最小的制造公差。Damon Q型支架的形状最为矩形,槽底与墙壁之间的角接近90度。达蒙的槽位高度平均超大3%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures. Evaluation of mechanical properties of esthetic brackets. Biomechanical aspects of segmented arch mechanics combined with power arm for controlled anterior tooth movement: A three-dimensional finite element study. The effect of perturbations on resistance to sliding in second-order moments comparing two different bracket types. Comparative study of mechanical properties of dental restorative materials and dental hard tissues in compressive loads.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1