Reliability and validity of a partial weight bearing measure of lower extremity performance.

Daniel J Cipriani, Michelle Haines, Denise O'Rand, Susan Levy
{"title":"Reliability and validity of a partial weight bearing measure of lower extremity performance.","authors":"Daniel J Cipriani,&nbsp;Michelle Haines,&nbsp;Denise O'Rand,&nbsp;Susan Levy","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Methods of measuring lower extremity function is limited for those with partial weight bearing (PWB) status in early phases of a lower extremity rehabilitation program.</p><p><strong>Objectives: </strong>The purpose of this study was to measure intra-rater reliability of two lower extremity PWB performance measures using an incline exercise apparatus and to evaluate the concurrent validity and responsiveness to change of these two measures.</p><p><strong>Methods: </strong>Thirty-seven adult patients with lower extremity injuries were measured on two PWB measures (PWB20 and PWB30) of lower extremity performance as well as several common measures of LE function. After initial testing, subjects were asked to return for retesting, following four to six weeks of rehabilitation intervention. Reliability of the data from the measures was tested using intraclass correlation coefficients (ICC); validity was based on bivariate correlations of the measures. The minimal detectable change (MDC) value and limb symmetry index (LSI) were used to study the responsiveness of the PWB measures.</p><p><strong>Results: </strong>The ICC for the PWB20 and PWB30 were 0.95 and 0.98, respectively. The bivariate correlations of the PWB20 with stair climbing and walking speed were greater than those of the PWB30. Correlations ranged from r = 0.49 to 0.72 between the PWB measures and the functional measures. For most patients, their change in score between initial testing and follow-up exceeded the MDC; the LSI improved for all patients.</p><p><strong>Conclusion: </strong>Using the incline apparatus yielded reliable PWB data. In addition, performance on the PWB measures correlated fairly well with common measures of function.</p>","PeriodicalId":88617,"journal":{"name":"North American journal of sports physical therapy : NAJSPT","volume":"4 2","pages":"49-59"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2953328/pdf/najspt-04-049.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"North American journal of sports physical therapy : NAJSPT","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Methods of measuring lower extremity function is limited for those with partial weight bearing (PWB) status in early phases of a lower extremity rehabilitation program.

Objectives: The purpose of this study was to measure intra-rater reliability of two lower extremity PWB performance measures using an incline exercise apparatus and to evaluate the concurrent validity and responsiveness to change of these two measures.

Methods: Thirty-seven adult patients with lower extremity injuries were measured on two PWB measures (PWB20 and PWB30) of lower extremity performance as well as several common measures of LE function. After initial testing, subjects were asked to return for retesting, following four to six weeks of rehabilitation intervention. Reliability of the data from the measures was tested using intraclass correlation coefficients (ICC); validity was based on bivariate correlations of the measures. The minimal detectable change (MDC) value and limb symmetry index (LSI) were used to study the responsiveness of the PWB measures.

Results: The ICC for the PWB20 and PWB30 were 0.95 and 0.98, respectively. The bivariate correlations of the PWB20 with stair climbing and walking speed were greater than those of the PWB30. Correlations ranged from r = 0.49 to 0.72 between the PWB measures and the functional measures. For most patients, their change in score between initial testing and follow-up exceeded the MDC; the LSI improved for all patients.

Conclusion: Using the incline apparatus yielded reliable PWB data. In addition, performance on the PWB measures correlated fairly well with common measures of function.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
下肢功能的部分负重测量的信度和效度。
背景:在下肢康复计划的早期阶段,测量部分负重(PWB)状态患者下肢功能的方法是有限的。目的:本研究的目的是测量两种使用倾斜运动器械的下肢PWB性能测量的内部信度,并评估这两种测量的并发效度和对变化的反应性。方法:对37例成年下肢损伤患者进行两项PWB指标(PWB20和PWB30)及几种常用的LE功能测量。在最初的测试之后,受试者被要求在四到六周的康复干预后返回进行重新测试。采用类内相关系数(ICC)检验测量数据的可靠性;效度基于测量的双变量相关性。采用最小可检测变化(MDC)值和肢体对称指数(LSI)来研究PWB措施的响应性。结果:PWB20和PWB30的ICC分别为0.95和0.98。PWB20与爬楼梯和步行速度的双变量相关性大于PWB30。PWB测量与功能测量之间的相关性为r = 0.49至0.72。对于大多数患者,他们在初始检测和随访之间的评分变化超过了MDC;所有患者的LSI均有改善。结论:采用倾斜仪可获得可靠的PWB数据。此外,在PWB测量上的性能与功能的常见测量相当好地相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Descriptive analysis of pitch volume in southeastern conference baseball pitchers. Reliability and exploration of the side-lying thoraco-lumbar rotation measurement (strm). The reliability, minimal detectable change and construct validity of a clinical measurement for identifying posterior shoulder tightness. The use of acetic Acid iontophoresis in the management of a soft tissue injury. Diagnosis of an ulnar collateral ligament tear using musculoskeletal ultrasound in a collegiate baseball pitcher: a case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1