Effects of mucosal thickness on the stress distribution and denture stability of mandibular implant-supported overdentures with unsplinted attachments in vitro.
{"title":"Effects of mucosal thickness on the stress distribution and denture stability of mandibular implant-supported overdentures with unsplinted attachments in vitro.","authors":"Asuka Haruta, Yasuyuki Matsushita, Yoshihiro Tsukiyama, Yoshinori Sawae, Nobuo Sakai, Kiyoshi Koyano","doi":"10.4061/2011/894395","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to compare the effects of mucosal thickness on the stress pattern around implants and movement of implant-supported overdentures with ball/female and three different types of magnetic attachments. After insertion of two root-form implants into a mandibular model, the surface of the model was covered with a 1.5- or 3-mm layer of impression material to simulate the oral mucosa, and removable overdentures were fabricated on each model. A 50-N vertical force was applied to the right first molar, and the resultant stress distribution and denture movement were measured. In the 1.5-mm mucosal model, the magnetic attachments showed significantly lower bending moments than did the ball attachment. The denture base displacement was the lowest on a magnetic attachment. In this study, use of magnetic attachments could be advantageous for mandibular implant-supported overdentures based on lower stress and better denture stability especially in the thin mucosal model.</p>","PeriodicalId":88916,"journal":{"name":"Journal of dental biomechanics","volume":"2011 ","pages":"894395"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4061/2011/894395","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4061/2011/894395","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/5/26 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
The aim of this study was to compare the effects of mucosal thickness on the stress pattern around implants and movement of implant-supported overdentures with ball/female and three different types of magnetic attachments. After insertion of two root-form implants into a mandibular model, the surface of the model was covered with a 1.5- or 3-mm layer of impression material to simulate the oral mucosa, and removable overdentures were fabricated on each model. A 50-N vertical force was applied to the right first molar, and the resultant stress distribution and denture movement were measured. In the 1.5-mm mucosal model, the magnetic attachments showed significantly lower bending moments than did the ball attachment. The denture base displacement was the lowest on a magnetic attachment. In this study, use of magnetic attachments could be advantageous for mandibular implant-supported overdentures based on lower stress and better denture stability especially in the thin mucosal model.