Effects of mucosal thickness on the stress distribution and denture stability of mandibular implant-supported overdentures with unsplinted attachments in vitro.

Journal of dental biomechanics Pub Date : 2011-01-01 Epub Date: 2011-05-26 DOI:10.4061/2011/894395
Asuka Haruta, Yasuyuki Matsushita, Yoshihiro Tsukiyama, Yoshinori Sawae, Nobuo Sakai, Kiyoshi Koyano
{"title":"Effects of mucosal thickness on the stress distribution and denture stability of mandibular implant-supported overdentures with unsplinted attachments in vitro.","authors":"Asuka Haruta,&nbsp;Yasuyuki Matsushita,&nbsp;Yoshihiro Tsukiyama,&nbsp;Yoshinori Sawae,&nbsp;Nobuo Sakai,&nbsp;Kiyoshi Koyano","doi":"10.4061/2011/894395","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to compare the effects of mucosal thickness on the stress pattern around implants and movement of implant-supported overdentures with ball/female and three different types of magnetic attachments. After insertion of two root-form implants into a mandibular model, the surface of the model was covered with a 1.5- or 3-mm layer of impression material to simulate the oral mucosa, and removable overdentures were fabricated on each model. A 50-N vertical force was applied to the right first molar, and the resultant stress distribution and denture movement were measured. In the 1.5-mm mucosal model, the magnetic attachments showed significantly lower bending moments than did the ball attachment. The denture base displacement was the lowest on a magnetic attachment. In this study, use of magnetic attachments could be advantageous for mandibular implant-supported overdentures based on lower stress and better denture stability especially in the thin mucosal model.</p>","PeriodicalId":88916,"journal":{"name":"Journal of dental biomechanics","volume":"2011 ","pages":"894395"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4061/2011/894395","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4061/2011/894395","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/5/26 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

The aim of this study was to compare the effects of mucosal thickness on the stress pattern around implants and movement of implant-supported overdentures with ball/female and three different types of magnetic attachments. After insertion of two root-form implants into a mandibular model, the surface of the model was covered with a 1.5- or 3-mm layer of impression material to simulate the oral mucosa, and removable overdentures were fabricated on each model. A 50-N vertical force was applied to the right first molar, and the resultant stress distribution and denture movement were measured. In the 1.5-mm mucosal model, the magnetic attachments showed significantly lower bending moments than did the ball attachment. The denture base displacement was the lowest on a magnetic attachment. In this study, use of magnetic attachments could be advantageous for mandibular implant-supported overdentures based on lower stress and better denture stability especially in the thin mucosal model.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
粘膜厚度对体外无夹板附着体下颌种植覆盖义齿应力分布及义齿稳定性的影响。
本研究的目的是比较三种不同类型磁性附着体和球形/母型种植覆盖义齿的粘膜厚度对种植体周围应力模式和运动的影响。将两个根状种植体插入下颌模型后,在模型表面覆盖1.5或3毫米的印模材料以模拟口腔黏膜,并在每个模型上制作可拆卸的覆盖义齿。对右第一磨牙施加50 n垂直力,测量应力分布和义齿移动情况。在1.5 mm粘膜模型中,磁性附着体的弯矩明显低于球形附着体。磁性附着体的义齿基托位移最小。在本研究中,磁性附着体的使用对下颌种植覆盖义齿具有更低的应力和更好的义齿稳定性,特别是在薄粘膜模型中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures. Evaluation of mechanical properties of esthetic brackets. Biomechanical aspects of segmented arch mechanics combined with power arm for controlled anterior tooth movement: A three-dimensional finite element study. The effect of perturbations on resistance to sliding in second-order moments comparing two different bracket types. Comparative study of mechanical properties of dental restorative materials and dental hard tissues in compressive loads.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1