Dose patient en neuroradiologie interventionnelle : bilan d’une enquête multicentrique

N. Kien, J.-L. Rehel, C. Étard, B. Aubert
{"title":"Dose patient en neuroradiologie interventionnelle : bilan d’une enquête multicentrique","authors":"N. Kien,&nbsp;J.-L. Rehel,&nbsp;C. Étard,&nbsp;B. Aubert","doi":"10.1016/j.jradio.2011.08.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>The purpose of this multicenter study was to determine the doses received by patients during interventional neuroradiology procedures and to consider establishing reference standards.</p></div><div><h3>Materials and methods</h3><p>A retrospective study of nine interventional neuroradiology departments was conducted. Seven diagnostic (cerebral and spinal angiography) and therapeutic (embolization and vertebroplasty) procedures were reviewed. For each procedure, three dosimetric parameters were recorded: dose-area product (DAP), fluoroscopy time, and number of images.</p></div><div><h3>Results</h3><p>Results showed interdepartment variations, up to four-fold for diagnostic procedures and seven-fold for therapeutic procedures. However, applying the 75th percentile method to the entire dataset, reference standards can be proposed for six types of procedures including diagnostic cerebral angiography (230 Gy<!--> <!-->cm<sup>2</sup>), follow-up selective cerebral angiography (80 Gy<!--> <!-->cm<sup>2</sup>), aneurysm embolization (350 Gy<!--> <!-->cm<sup>2</sup>), AVM embolization (440 Gy<!--> <!-->cm<sup>2</sup>). Reference standards are also proposed with regards to fluoroscopy time and number of images.</p></div><div><h3>Conclusion</h3><p>Such standards are useful for clinicians to evaluate and improve their practices.</p></div>","PeriodicalId":14813,"journal":{"name":"Journal De Radiologie","volume":"92 12","pages":"Pages 1101-1112"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jradio.2011.08.005","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal De Radiologie","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0221036311003830","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

Abstract

Purpose

The purpose of this multicenter study was to determine the doses received by patients during interventional neuroradiology procedures and to consider establishing reference standards.

Materials and methods

A retrospective study of nine interventional neuroradiology departments was conducted. Seven diagnostic (cerebral and spinal angiography) and therapeutic (embolization and vertebroplasty) procedures were reviewed. For each procedure, three dosimetric parameters were recorded: dose-area product (DAP), fluoroscopy time, and number of images.

Results

Results showed interdepartment variations, up to four-fold for diagnostic procedures and seven-fold for therapeutic procedures. However, applying the 75th percentile method to the entire dataset, reference standards can be proposed for six types of procedures including diagnostic cerebral angiography (230 Gy cm2), follow-up selective cerebral angiography (80 Gy cm2), aneurysm embolization (350 Gy cm2), AVM embolization (440 Gy cm2). Reference standards are also proposed with regards to fluoroscopy time and number of images.

Conclusion

Such standards are useful for clinicians to evaluate and improve their practices.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
介入神经放射学中的患者剂量:多中心调查的结果
目的本多中心研究的目的是确定患者在介入神经放射学手术中接受的剂量,并考虑建立参考标准。材料与方法对9个介入神经放射科进行回顾性研究。回顾了七种诊断(脑和脊髓血管造影)和治疗(栓塞和椎体成形术)的方法。对于每个程序,记录三个剂量学参数:剂量面积积(DAP),透视时间和图像数量。结果显示科室间差异,诊断程序高达4倍,治疗程序高达7倍。然而,将第75个百分点方法应用于整个数据集,可以提出六种手术的参考标准,包括诊断性脑血管造影(230 Gy cm2),随访选择性脑血管造影(80 Gy cm2),动脉瘤栓塞(350 Gy cm2), AVM栓塞(440 Gy cm2)。同时提出了关于透视时间和图像数量的参考标准。结论该标准对临床医生评价和改进临床实践有一定的参考价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
相关文献
Reinforcement of bionic trabecular bone scaffolds for bone defect repair using the slime mould algorithm
IF 8.4 2区 材料科学Materials & DesignPub Date : 2023-09-01 DOI: 10.1016/j.matdes.2023.112184
Deyin Kong , Zhongxiong Kang , Chaorui Jiang , Zhihui Zhang , Xiebin Wang , Qing Han , Yanbin Shi
The design and evaluation of bionic porous bone scaffolds in fluid flow characteristics and mechanical properties
IF 6.1 2区 医学Computer methods and programs in biomedicinePub Date : 2022-10-01 DOI: 10.1016/j.cmpb.2022.107059
Xinpei Li , Yanen Wang , Bo Zhang , Haozhe Yang , Ray Tahir Mushtaq , Minyan Liu , Chengwei Bao , Yikai Shi , Zhuojing Luo , Weihong Zhang
来源期刊
Journal De Radiologie
Journal De Radiologie 医学-核医学
自引率
0.00%
发文量
1
审稿时长
>12 weeks
期刊最新文献
Financial inclusion and environmental sustainability in Ghana: application of the dynamic ARDL estimator. A natural genetic variation screen identifies insulin signaling, neuronal communication, and innate immunity as modifiers of hyperglycemia in the absence of Sirt1. [Epidemiological characteristics and treatment outcome analysis of 229 patients with hydrofluoric acid burns in hands]. Quel est votre diagnostic ? [Interventional radiology].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1