Critical appraisal of cardiac implantable electronic devices: complications and management.

IF 1.3 Q4 ENGINEERING, BIOMEDICAL Medical Devices-Evidence and Research Pub Date : 2011-01-01 Epub Date: 2011-09-09 DOI:10.2147/MDER.S15059
Luigi Padeletti, Giosuè Mascioli, Alessandro Paoletti Perini, Gino Grifoni, Laura Perrotta, Procolo Marchese, Luca Bontempi, Antonio Curnis
{"title":"Critical appraisal of cardiac implantable electronic devices: complications and management.","authors":"Luigi Padeletti,&nbsp;Giosuè Mascioli,&nbsp;Alessandro Paoletti Perini,&nbsp;Gino Grifoni,&nbsp;Laura Perrotta,&nbsp;Procolo Marchese,&nbsp;Luca Bontempi,&nbsp;Antonio Curnis","doi":"10.2147/MDER.S15059","DOIUrl":null,"url":null,"abstract":"<p><p>Population aging and broader indications for the implant of cardiac implantable electronic devices (CIEDs) are the main reasons for the continuous increase in the use of pacemakers (PMs), implantable cardioverter-defibrillators (ICDs) and devices for cardiac resynchronization therapy (CRT-P, CRT-D). The growing burden of comorbidities in CIED patients, the greater complexity of the devices, and the increased duration of procedures have led to an augmented risk of infections, which is out of proportion to the increase in implantation rate. CIED infections are an ominous condition, which often implies the necessity of hospitalization and carries an augmented risk of in-hospital death. Their clinical presentation may be either at pocket or at endocardial level, but they can also manifest themselves with lone bacteremia. The management of these infections requires the complete removal of the device and subsequent, specific, antibiotic therapy. CIED failures are monitored by competent public authorities, that require physicians to alert them to any failures, and that suggest the opportune strategies for their management. Although the replacement of all potentially affected devices is often suggested, common practice indicates the replacement of only a minority of devices, as close follow-up of the patients involved may be a safer strategy. Implantation of a PM or an ICD may cause problems in the patients' psychosocial adaptation and quality of life, and may contribute to the development of affective disorders. Clinicians are usually unaware of the psychosocial impact of implanted PMs and ICDs. The main difference between PM and ICD patients is the latter's dramatic experience of receiving a shock. Technological improvements and new clinical evidences may help reduce the total burden of shocks. A specific supporting team, providing psychosocial help, may contribute to improving patient quality of life.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":" ","pages":"157-67"},"PeriodicalIF":1.3000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2147/MDER.S15059","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S15059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/9/9 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 10

Abstract

Population aging and broader indications for the implant of cardiac implantable electronic devices (CIEDs) are the main reasons for the continuous increase in the use of pacemakers (PMs), implantable cardioverter-defibrillators (ICDs) and devices for cardiac resynchronization therapy (CRT-P, CRT-D). The growing burden of comorbidities in CIED patients, the greater complexity of the devices, and the increased duration of procedures have led to an augmented risk of infections, which is out of proportion to the increase in implantation rate. CIED infections are an ominous condition, which often implies the necessity of hospitalization and carries an augmented risk of in-hospital death. Their clinical presentation may be either at pocket or at endocardial level, but they can also manifest themselves with lone bacteremia. The management of these infections requires the complete removal of the device and subsequent, specific, antibiotic therapy. CIED failures are monitored by competent public authorities, that require physicians to alert them to any failures, and that suggest the opportune strategies for their management. Although the replacement of all potentially affected devices is often suggested, common practice indicates the replacement of only a minority of devices, as close follow-up of the patients involved may be a safer strategy. Implantation of a PM or an ICD may cause problems in the patients' psychosocial adaptation and quality of life, and may contribute to the development of affective disorders. Clinicians are usually unaware of the psychosocial impact of implanted PMs and ICDs. The main difference between PM and ICD patients is the latter's dramatic experience of receiving a shock. Technological improvements and new clinical evidences may help reduce the total burden of shocks. A specific supporting team, providing psychosocial help, may contribute to improving patient quality of life.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
心脏植入式电子装置的关键评估:并发症和处理。
人口老龄化和心脏植入式电子装置(cied)植入适应症的扩大是心脏起搏器(pm)、植入式心律转复除颤器(ICDs)和心脏再同步化治疗装置(CRT-P、CRT-D)使用持续增加的主要原因。CIED患者的合并症负担越来越重,设备的复杂性越来越高,手术时间越来越长,导致感染风险增加,这与植入率的增加不成比例。CIED感染是一种不祥之兆,通常意味着住院治疗的必要性,并增加院内死亡的风险。它们的临床表现可能在口袋或心内膜水平,但它们也可以表现为单独的菌血症。这些感染的管理需要完全移除装置和随后的特异性抗生素治疗。CIED故障由主管的公共当局监测,这要求医生提醒他们任何故障,并建议适当的管理策略。虽然经常建议更换所有可能受影响的装置,但通常的做法表明只更换少数装置,因为密切随访相关患者可能是一种更安全的策略。植入PM或ICD可能会导致患者的社会心理适应和生活质量出现问题,并可能导致情感性障碍的发展。临床医生通常不知道植入pmm和icd的社会心理影响。PM和ICD患者之间的主要区别是后者接受休克的戏剧性经历。技术进步和新的临床证据可能有助于减少休克的总负担。提供心理社会帮助的特定支持团队可能有助于改善患者的生活质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
期刊最新文献
Initial Validation of the NOL Nociception Level Index® Monitoring System in Black and Multiracial People. Potential of Aluminum Drug Packages with Press-Through Packaging Considering Usability for a Wide Range of Users. The Application Effect of Fine Management Combined with Man-Machine Fixation Mode in Reducing the Attrition Rate of Laparoscopic Instruments-A Non-Randomized, Concurrent Controlled Study. Patients with Growth-Related Disorders and Caregivers Prefer the Somapacitan Device to the Somatrogon Device: Results from a Randomized Crossover Study Assessing Device Preference and Ease of Use Following Simulated Injections. May Glymphatic Drainage Improve Life Quality in Progressive Multiple Sclerosis Outpatients?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1