Device and materials for in vitro evaluation of forces developed to teeth and periodontal structures during dental practices.

Journal of dental biomechanics Pub Date : 2013-09-04 eCollection Date: 2013-01-01 DOI:10.1177/1758736013503648
Fotios D Palamidakis, Athanasia Panou, Kyriaki G Papadokostaki, George Leontakianakos, Vassilis N Stathopoulos, Evangelos G Kontakiotis
{"title":"Device and materials for in vitro evaluation of forces developed to teeth and periodontal structures during dental practices.","authors":"Fotios D Palamidakis,&nbsp;Athanasia Panou,&nbsp;Kyriaki G Papadokostaki,&nbsp;George Leontakianakos,&nbsp;Vassilis N Stathopoulos,&nbsp;Evangelos G Kontakiotis","doi":"10.1177/1758736013503648","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed at providing a gauge device (Ekontak et al Gauge K-Device) in order to analyze the forces applied to teeth and periodontal tissues during dental practices in vitro. This force gauge device can be used in the investigation of the possible defect generation to tooth structures when overloaded forces are applied during dental procedures in vitro. Ekontak et al Gauge K-Device consists of three units: the specimen's holder, a high-performance digital force gauge, and the support frame. The holder was fabricated by an Al alloy providing a steady detachable attachment between the specimens and the force gauge's pin connector. The clinical simulation was achieved with the use of a proper silicone material, selected to provide similar elastic behavior with the human periodontal ligament and to join the teeth inside a solid matrix of an acrylic resin. The digital force gauge is a high-speed collection and recording (1000 Hz) product coupled with data recording software. The forces developed to 15 specimens' root canals during lateral condensation and vertical compaction of cold gutta-percha obturation procedures were monitored, saved as graphs, CSV, and excel files and presented over time. The forces developed during vertical compaction (mean maximum force per obturation circle = 13.22 N) were more excessive than those during lateral condensation (mean maximum force per obturation circle = 10.14 N). In conclusion, Ekontak et al Gauge K-Device is provided as a modern gauge device, capable of performing clinical simulation in vitro, under the terms of its protocol. </p>","PeriodicalId":88916,"journal":{"name":"Journal of dental biomechanics","volume":"4 ","pages":"1758736013503648"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1758736013503648","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1758736013503648","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This study aimed at providing a gauge device (Ekontak et al Gauge K-Device) in order to analyze the forces applied to teeth and periodontal tissues during dental practices in vitro. This force gauge device can be used in the investigation of the possible defect generation to tooth structures when overloaded forces are applied during dental procedures in vitro. Ekontak et al Gauge K-Device consists of three units: the specimen's holder, a high-performance digital force gauge, and the support frame. The holder was fabricated by an Al alloy providing a steady detachable attachment between the specimens and the force gauge's pin connector. The clinical simulation was achieved with the use of a proper silicone material, selected to provide similar elastic behavior with the human periodontal ligament and to join the teeth inside a solid matrix of an acrylic resin. The digital force gauge is a high-speed collection and recording (1000 Hz) product coupled with data recording software. The forces developed to 15 specimens' root canals during lateral condensation and vertical compaction of cold gutta-percha obturation procedures were monitored, saved as graphs, CSV, and excel files and presented over time. The forces developed during vertical compaction (mean maximum force per obturation circle = 13.22 N) were more excessive than those during lateral condensation (mean maximum force per obturation circle = 10.14 N). In conclusion, Ekontak et al Gauge K-Device is provided as a modern gauge device, capable of performing clinical simulation in vitro, under the terms of its protocol.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在牙科实践中用于牙齿和牙周结构的力的体外评估的装置和材料。
本研究旨在提供一种测量装置(Ekontak et al . gauge K-Device),以便在体外牙科实践中分析牙齿和牙周组织所受的力。该力计装置可用于研究在体外牙科手术过程中施加过载力时牙齿结构可能产生的缺陷。Ekontak等人的测量装置由三个部分组成:试样支架、高性能数字测力仪和支撑架。支架由铝合金制成,在试样和测力计的销接头之间提供稳定的可拆卸连接。临床模拟是通过使用合适的硅酮材料来实现的,硅酮材料的选择提供了与人类牙周韧带相似的弹性行为,并将牙齿连接在丙烯酸树脂的固体基质中。数字力计是一个高速采集和记录(1000赫兹)的产品加上数据记录软件。对15个标本的根管在冷胶充填过程中侧向凝结和垂直压实过程中受力情况进行监测,保存为图形、CSV和excel文件,并随时间呈现。垂直压缩过程中产生的力(每个封闭圈的平均最大力= 13.22 N)比侧向压缩过程中产生的力(每个封闭圈的平均最大力= 10.14 N)更大。总之,Ekontak等人的Gauge K-Device是一种现代的测量装置,能够在体外进行临床模拟,根据其协议条款。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures. Evaluation of mechanical properties of esthetic brackets. Biomechanical aspects of segmented arch mechanics combined with power arm for controlled anterior tooth movement: A three-dimensional finite element study. The effect of perturbations on resistance to sliding in second-order moments comparing two different bracket types. Comparative study of mechanical properties of dental restorative materials and dental hard tissues in compressive loads.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1