The cutoff value of saphenous vein diameter to predict reflux.

Journal of the Korean Surgical Society Pub Date : 2013-10-01 Epub Date: 2013-09-30 DOI:10.4174/jkss.2013.85.4.169
Jin Hyun Joh, Ho-Chul Park
{"title":"The cutoff value of saphenous vein diameter to predict reflux.","authors":"Jin Hyun Joh,&nbsp;Ho-Chul Park","doi":"10.4174/jkss.2013.85.4.169","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Increased saphenous vein diameter is a common consequence of saphenous vein reflux. Until now, there have been no reports about the correlation between diameter and reflux of saphenous vein in Korea. The aim of this study was to investigate the correlation between saphenous vein reflux and diameter changes.</p><p><strong>Methods: </strong>From April 2009 to August 2012, 777 patients were sent to the vascular laboratory for evaluation of venous reflux. The diameter of the saphenous vein was measured with B-mode imaging, and reflux was quantified based on valve closure time using Doppler spectral tracings. Receiver operating characteristics curve analysis was applied to determine the best saphenous vein diameter cutoff for predicting reflux.</p><p><strong>Results: </strong>The mean diameters of normal great saphenous vein (GSV) and refluxed GSV were 5.0 ± 2.4 mm and 6.4 ± 2.0 mm, respectively. The mean diameters of normal small saphenous vein (SSV) and refluxed SSV were 3.1 ± 1.3 mm and 5.2 ± 2.7 mm, respectively. The diameter differences between the normal and refluxed GSV and SSV were 1.4 mm and 2.1 mm, respectively, and these differences were statistically significant (P < 0.0001). A GSV threshold diameter of 5.05 mm had the best positive predictive value for reflux. The sensitivity and specificity at 5.05 mm were 76% and 60%, respectively. The best SSV diameter for predicting reflux was 3.55 mm. The sensitivity and specificity at 3.55 mm were 87% and 71%, respectively.</p><p><strong>Conclusion: </strong>GSV diameter of ≥5.05 mm had the best positive predictive value for pathologic reflux. For pathologic reflux of SSV, the best cutoff diameter was 3.55 mm.</p>","PeriodicalId":49991,"journal":{"name":"Journal of the Korean Surgical Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4174/jkss.2013.85.4.169","citationCount":"28","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Surgical Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4174/jkss.2013.85.4.169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/9/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 28

Abstract

Purpose: Increased saphenous vein diameter is a common consequence of saphenous vein reflux. Until now, there have been no reports about the correlation between diameter and reflux of saphenous vein in Korea. The aim of this study was to investigate the correlation between saphenous vein reflux and diameter changes.

Methods: From April 2009 to August 2012, 777 patients were sent to the vascular laboratory for evaluation of venous reflux. The diameter of the saphenous vein was measured with B-mode imaging, and reflux was quantified based on valve closure time using Doppler spectral tracings. Receiver operating characteristics curve analysis was applied to determine the best saphenous vein diameter cutoff for predicting reflux.

Results: The mean diameters of normal great saphenous vein (GSV) and refluxed GSV were 5.0 ± 2.4 mm and 6.4 ± 2.0 mm, respectively. The mean diameters of normal small saphenous vein (SSV) and refluxed SSV were 3.1 ± 1.3 mm and 5.2 ± 2.7 mm, respectively. The diameter differences between the normal and refluxed GSV and SSV were 1.4 mm and 2.1 mm, respectively, and these differences were statistically significant (P < 0.0001). A GSV threshold diameter of 5.05 mm had the best positive predictive value for reflux. The sensitivity and specificity at 5.05 mm were 76% and 60%, respectively. The best SSV diameter for predicting reflux was 3.55 mm. The sensitivity and specificity at 3.55 mm were 87% and 71%, respectively.

Conclusion: GSV diameter of ≥5.05 mm had the best positive predictive value for pathologic reflux. For pathologic reflux of SSV, the best cutoff diameter was 3.55 mm.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
预测反流的隐静脉直径临界值。
目的:隐静脉直径增大是隐静脉返流的常见后果。到目前为止,还没有关于韩国隐静脉直径与反流之间关系的报道。本研究的目的是探讨隐静脉反流与直径变化之间的关系。方法:2009年4月至2012年8月,将777例患者送往血管实验室进行静脉反流评估。b型显像测量大隐静脉直径,多普勒光谱示踪根据瓣膜关闭时间量化反流。应用受试者工作特征曲线分析确定预测反流的最佳隐静脉直径截止值。结果:正常大隐静脉和回流大隐静脉的平均直径分别为5.0±2.4 mm和6.4±2.0 mm。正常小隐静脉和回流小隐静脉的平均直径分别为3.1±1.3 mm和5.2±2.7 mm。正常GSV与回流GSV、SSV的直径差异分别为1.4 mm和2.1 mm,差异有统计学意义(P < 0.0001)。GSV阈值直径为5.05 mm对反流有最好的阳性预测值。5.05 mm处的敏感性为76%,特异性为60%。预测反流的最佳SSV直径为3.55 mm。3.55 mm的敏感性为87%,特异性为71%。结论:GSV直径≥5.05 mm对病理性反流的阳性预测价值最好。对于SSV病理性返流,最佳切断直径为3.55 mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Matrix Metalloproteinase 41 : inside the presidency of George H.W. Bush Risk factors for lymph node metastasis in mucosal gastric cancer and re-evaluation of endoscopic submucosal dissection The optimal follow-up period in patients with above 5-year disease-free survival after curative liver resection for hepatocellular carcinoma. The comparison of single incision laparoscopic cholecystectomy and three port laparoscopic cholecystectomy: prospective randomized study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1