Beamline simulations using monochromators with high d-spacing crystals.

IF 2.4 3区 物理与天体物理 Q2 INSTRUMENTS & INSTRUMENTATION Journal of Synchrotron Radiation Pub Date : 2022-09-01 Epub Date: 2022-08-12 DOI:10.1107/S160057752200707X
X J Yu, X Chi, T Smulders, A T S Wee, A Rusydi, M Sanchez Del Rio, M B H Breese
{"title":"Beamline simulations using monochromators with high d-spacing crystals.","authors":"X J Yu,&nbsp;X Chi,&nbsp;T Smulders,&nbsp;A T S Wee,&nbsp;A Rusydi,&nbsp;M Sanchez Del Rio,&nbsp;M B H Breese","doi":"10.1107/S160057752200707X","DOIUrl":null,"url":null,"abstract":"<p><p>Monochromators for synchrotron radiation beamlines typically use perfect crystals for the hard X-ray regime and gratings for soft X-rays. There is an intermediate range, typically 1-3 keV (tender X-rays), which common perfect crystals have difficulties covering and gratings have low efficiency, although some less common crystals with high d-spacing could be suitable. To evaluate the suitability of these crystals for a particular beamline, it is useful to evaluate the crystals' performance using tools such as ray-tracing. However, simulations for double-crystal monochromators are only available for the most used crystals such as Si, Ge or diamond. Here, an upgrade of the SHADOW ray-tracing code and complementary tools in the OASYS suite are presented to simulate high d-spacing crystals with arbitrary, and sometimes complex, structures such as beryl, YB<sub>66</sub>, muscovite, etc. Isotropic and anisotropic temperature factors are also considered. The YB<sub>66</sub> crystal with 1936 atomic sites in the unit cell is simulated, and its applicability for tender X-ray monochromators is discussed in the context of new low-emittance storage rings.</p>","PeriodicalId":17114,"journal":{"name":"Journal of Synchrotron Radiation","volume":"29 Pt 5","pages":"1157-1166"},"PeriodicalIF":2.4000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9455208/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Synchrotron Radiation","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1107/S160057752200707X","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Monochromators for synchrotron radiation beamlines typically use perfect crystals for the hard X-ray regime and gratings for soft X-rays. There is an intermediate range, typically 1-3 keV (tender X-rays), which common perfect crystals have difficulties covering and gratings have low efficiency, although some less common crystals with high d-spacing could be suitable. To evaluate the suitability of these crystals for a particular beamline, it is useful to evaluate the crystals' performance using tools such as ray-tracing. However, simulations for double-crystal monochromators are only available for the most used crystals such as Si, Ge or diamond. Here, an upgrade of the SHADOW ray-tracing code and complementary tools in the OASYS suite are presented to simulate high d-spacing crystals with arbitrary, and sometimes complex, structures such as beryl, YB66, muscovite, etc. Isotropic and anisotropic temperature factors are also considered. The YB66 crystal with 1936 atomic sites in the unit cell is simulated, and its applicability for tender X-ray monochromators is discussed in the context of new low-emittance storage rings.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用高d间距晶体单色仪进行光束线模拟。
用于同步辐射光束线的单色仪通常使用完美的硬x射线晶体和软x射线光栅。有一个中间范围,通常是1-3 keV(温柔的x射线),普通的完美晶体很难覆盖,光栅效率低,尽管一些不太常见的高d间距晶体可能是合适的。为了评估这些晶体对特定光束线的适用性,使用诸如光线追踪之类的工具来评估晶体的性能是有用的。然而,双晶单色仪的模拟只适用于最常用的晶体,如Si, Ge或金刚石。本文提出了SHADOW光线追踪代码的升级版和OASYS套件中的补充工具,用于模拟具有任意(有时是复杂)结构的高d间距晶体,如绿宝石、YB66、白云母等。同时考虑了各向同性和各向异性的温度因素。对具有1936个原子位的YB66晶体进行了模拟,并在新型低发射度存储环的背景下讨论了其在软x射线单色仪中的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
12.00%
发文量
289
审稿时长
4-8 weeks
期刊介绍: Synchrotron radiation research is rapidly expanding with many new sources of radiation being created globally. Synchrotron radiation plays a leading role in pure science and in emerging technologies. The Journal of Synchrotron Radiation provides comprehensive coverage of the entire field of synchrotron radiation and free-electron laser research including instrumentation, theory, computing and scientific applications in areas such as biology, nanoscience and materials science. Rapid publication ensures an up-to-date information resource for scientists and engineers in the field.
期刊最新文献
Operando double-edge high-resolution X-ray absorption spectroscopy study of BiVO4 photoanodes Development of dual-beamline photoelectron momentum microscopy for valence orbital analysis Measuring magnetic hysteresis curves with polarized soft X-ray resonant reflectivity High-pressure X-ray photon correlation spectroscopy at fourth-generation synchrotron sources Iterative Bragg peak removal on X-ray absorption spectra with automatic intensity correction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1