Daniel J. Romero, Gary P. Jacobson, Richard A. Roberts
{"title":"The effect of EMG magnitude on the masseter vestibular evoked myogenic potential (mVEMP)","authors":"Daniel J. Romero, Gary P. Jacobson, Richard A. Roberts","doi":"10.1016/j.joto.2022.06.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>The masseter vestibular evoked myogenic potential (mVEMP) is a bilaterally generated, electromyographically (EMG)-mediated response innervated by the trigeminal nerve. The purpose of the present investigation was to 1) determine whether subjects could accurately achieve and maintain a range of EMG target levels, 2) to examine the effects of varied EMG levels on the latencies and amplitudes of the mVEMP, and 3) to investigate the degree of side-to-side asymmetry and any effects of EMG activation.</p></div><div><h3>Methods</h3><p>Subjects were nine neurologically and otologically normal young adults. A high-intensity tone burst was presented monaurally while subjects were seated upright and asked to match a range of EMG target levels by clenching their teeth. Recordings were made from the ipsilateral and contralateral masseter muscles referenced to the ear being monaurally stimulated.</p></div><div><h3>Results</h3><p>We found that the tonic EMG target had no effect on mVEMP latency. Additionally, although mVEMP amplitudes “scaled” to the EMG target, there was a tendency for the subjects’ EMG level to “undershoot” the EMG target levels greater than 50 μV. While some individuals did generate differences in EMG activation between sides, there were no significant differences on average EMG activation between sides. Further, while average corrected amplitude asymmetry was similar across EMG targets, some individuals demonstrated large, corrected amplitude asymmetry ratios.</p></div><div><h3>Conclusions</h3><p>The results of this investigation suggest that, as with cVEMP recordings, the underlying EMG activation may vary between subjects and could impact mVEMP amplitudes, yet could be mitigated by amplitude correction techniques. Further it is important to be aware that even young normal subjects have difficulty maintaining large, tonic EMG activity during the mVEMP recording.</p></div>","PeriodicalId":37466,"journal":{"name":"Journal of Otology","volume":"17 4","pages":"Pages 203-210"},"PeriodicalIF":1.4000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9547109/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Otology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1672293022000472","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 2
Abstract
Introduction
The masseter vestibular evoked myogenic potential (mVEMP) is a bilaterally generated, electromyographically (EMG)-mediated response innervated by the trigeminal nerve. The purpose of the present investigation was to 1) determine whether subjects could accurately achieve and maintain a range of EMG target levels, 2) to examine the effects of varied EMG levels on the latencies and amplitudes of the mVEMP, and 3) to investigate the degree of side-to-side asymmetry and any effects of EMG activation.
Methods
Subjects were nine neurologically and otologically normal young adults. A high-intensity tone burst was presented monaurally while subjects were seated upright and asked to match a range of EMG target levels by clenching their teeth. Recordings were made from the ipsilateral and contralateral masseter muscles referenced to the ear being monaurally stimulated.
Results
We found that the tonic EMG target had no effect on mVEMP latency. Additionally, although mVEMP amplitudes “scaled” to the EMG target, there was a tendency for the subjects’ EMG level to “undershoot” the EMG target levels greater than 50 μV. While some individuals did generate differences in EMG activation between sides, there were no significant differences on average EMG activation between sides. Further, while average corrected amplitude asymmetry was similar across EMG targets, some individuals demonstrated large, corrected amplitude asymmetry ratios.
Conclusions
The results of this investigation suggest that, as with cVEMP recordings, the underlying EMG activation may vary between subjects and could impact mVEMP amplitudes, yet could be mitigated by amplitude correction techniques. Further it is important to be aware that even young normal subjects have difficulty maintaining large, tonic EMG activity during the mVEMP recording.
期刊介绍:
Journal of Otology is an open access, peer-reviewed journal that publishes research findings from disciplines related to both clinical and basic science aspects of auditory and vestibular system and diseases of the ear. This journal welcomes submissions describing original experimental research that may improve our understanding of the mechanisms underlying problems of basic or clinical significance and treatment of patients with disorders of the auditory and vestibular systems. In addition to original papers the journal also offers invited review articles on current topics written by leading experts in the field. The journal is of primary importance for all scientists and practitioners interested in audiology, otology and neurotology, auditory neurosciences and related disciplines. Journal of Otology welcomes contributions from scholars in all countries and regions across the world.