Application of Real-Time Tissue Elastography with a Low Frequency Convex Array Probe: A Noninvasive Approach to Differential Diagnosis of Liver Tumors.

ISRN hepatology Pub Date : 2014-04-01 eCollection Date: 2014-01-01 DOI:10.1155/2014/378243
Juan Wang, Hong Ai, Long Guo, Lifang Tan, Huilin Gong, Wei Wei, Litao Ruan
{"title":"Application of Real-Time Tissue Elastography with a Low Frequency Convex Array Probe: A Noninvasive Approach to Differential Diagnosis of Liver Tumors.","authors":"Juan Wang,&nbsp;Hong Ai,&nbsp;Long Guo,&nbsp;Lifang Tan,&nbsp;Huilin Gong,&nbsp;Wei Wei,&nbsp;Litao Ruan","doi":"10.1155/2014/378243","DOIUrl":null,"url":null,"abstract":"<p><p>To evaluate diagnostic performance of real-time tissue elastography (RTE) with a low frequency convex array probe for distinguishing benign from malignant hepatic tumors through trans-abdominal examination, elasticity images of 210 liver tumors were obtained by EUB-7500 (Hitachi Medical Systems and 3.5 MHz probe) and eventually 121 liver tumors were analyzed in the study. Elasticity images were classified into four types, from type a to d. Regarding type a or b as benign tumors and type c or d as malignant ones, sensitivity, specificity, and accuracy were calculated and the consistency between the findings of RTE and the pathohistological diagnosis was evaluated. The sensitivity, specificity, and accuracy were separately 97.2%, 88.0%, and 93.4% (P < 0.001). Moreover, there was a good consistency between the findings of RTE and the pathological diagnosis (kappa value 0.86). Among elasticity images of all the malignant tumors, the hepatocellular carcinomas (HCCs) mainly appeared in type c, and liver metastatic cancers in type d. Thus, RTE utilized as a novel noninvasive imaging examination method enables us to distinguish benign from malignant liver tumors. Moreover, it provides certain information for the differential diagnosis between HCCs and liver metastatic cancers. </p>","PeriodicalId":91521,"journal":{"name":"ISRN hepatology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2014/378243","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN hepatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2014/378243","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2014/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

To evaluate diagnostic performance of real-time tissue elastography (RTE) with a low frequency convex array probe for distinguishing benign from malignant hepatic tumors through trans-abdominal examination, elasticity images of 210 liver tumors were obtained by EUB-7500 (Hitachi Medical Systems and 3.5 MHz probe) and eventually 121 liver tumors were analyzed in the study. Elasticity images were classified into four types, from type a to d. Regarding type a or b as benign tumors and type c or d as malignant ones, sensitivity, specificity, and accuracy were calculated and the consistency between the findings of RTE and the pathohistological diagnosis was evaluated. The sensitivity, specificity, and accuracy were separately 97.2%, 88.0%, and 93.4% (P < 0.001). Moreover, there was a good consistency between the findings of RTE and the pathological diagnosis (kappa value 0.86). Among elasticity images of all the malignant tumors, the hepatocellular carcinomas (HCCs) mainly appeared in type c, and liver metastatic cancers in type d. Thus, RTE utilized as a novel noninvasive imaging examination method enables us to distinguish benign from malignant liver tumors. Moreover, it provides certain information for the differential diagnosis between HCCs and liver metastatic cancers.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
实时组织弹性成像与低频凸阵列探针的应用:一种无创肝肿瘤鉴别诊断方法。
为了评估低频凸阵探头实时组织弹性成像(RTE)对经腹肝肿瘤良恶性鉴别的诊断效果,我们使用EUB-7500(日立医疗系统公司,3.5 MHz探头)获取了210个肝脏肿瘤的弹性图像,最终分析了121个肝脏肿瘤。将弹性图像分为a - d四种类型,将a型或b型为良性肿瘤,c型或d型为恶性肿瘤,计算其敏感性、特异性和准确性,并评价RTE的表现与病理组织学诊断的一致性。灵敏度为97.2%,特异性为88.0%,准确度为93.4% (P < 0.001)。RTE表现与病理诊断具有较好的一致性(kappa值0.86)。在所有恶性肿瘤的弹性图像中,肝细胞癌(hcc)主要出现在c型,肝转移癌主要出现在d型。因此,RTE作为一种新的无创影像学检查方法,使我们能够区分肝肿瘤的良恶性。此外,它为hcc和肝转移癌的鉴别诊断提供了一定的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Hepatic Encephalopathy: From the Pathogenesis to the New Treatments. The Wide and Complex Field of NAFLD Biomarker Research: Trends. Application of Real-Time Tissue Elastography with a Low Frequency Convex Array Probe: A Noninvasive Approach to Differential Diagnosis of Liver Tumors. The Evolution of Transjugular Intrahepatic Portosystemic Shunt: Tips. Liver Transplantation for Hepatocellular Carcinoma beyond Milan Criteria: Multidisciplinary Approach to Improve Outcome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1