S Kaul, J Zimmer, O Dehus, A Constanzo, A Daas, K-H Buchheit, J Asturias, M C Arilla, D Barber, A Bertocchi, B Brunetto, J A Carnes, M Chapman, G Chaudemanche, J Dayan-Kenigsberg, S Döring, F Führer, M T Gallego, P Iacovacci, K M Hanschmann, T Holzhauser, M Hrabina, A Ledesma, P Moingeon, E Nony, C Pini, G Plunkett, M Raulf, G Reese, E Sandberg, I Sander, B Smith, D Strecker, C Valerio, R van Ree, B Weber, S Vieths
{"title":"Validation of ELISA methods for quantification of the major birch allergen Bet v 1 (BSP090).","authors":"S Kaul, J Zimmer, O Dehus, A Constanzo, A Daas, K-H Buchheit, J Asturias, M C Arilla, D Barber, A Bertocchi, B Brunetto, J A Carnes, M Chapman, G Chaudemanche, J Dayan-Kenigsberg, S Döring, F Führer, M T Gallego, P Iacovacci, K M Hanschmann, T Holzhauser, M Hrabina, A Ledesma, P Moingeon, E Nony, C Pini, G Plunkett, M Raulf, G Reese, E Sandberg, I Sander, B Smith, D Strecker, C Valerio, R van Ree, B Weber, S Vieths","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>To date, the potency of allergen products in Europe is expressed in manufacturer-specific units relative to a product-specific in-house reference. Consequently, cross-product comparability of allergen products from different manufacturers with respect to strength and efficacy is impossible. The Biological Standardisation Programme (BSP) project BSP090 addresses this issue via the establishment of reference standards in conjunction with ELISA methods for the quantification of major allergens in allergen products. Since the initiation of BSP090, the recombinant major allergen Bet v 1 has been adopted by the European Pharmacopoeia Commission as a Chemical Reference Substance (CRS). In parallel, two sandwich ELISA systems for quantification of Bet v 1 were found suitable in preliminary phases of BSP090 to be validated in a large collaborative study. In this study, the candidate ELISA systems were compared with respect to accuracy, precision and variability. Thirteen participating laboratories tested model samples containing the CRS as well as spiked and unspiked birch pollen extracts. Both in pre-testing and in the collaborative study, the 2 candidate ELISA systems confirmed their suitability to quantify recombinant and native Bet v 1. As no clear-cut decision for one of the ELISA systems could be made based on the results of the collaborative study, a post-study testing was performed. Bet v 1 content of 30 birch pollen allergen products was determined in parallel in both ELISA systems. Consequently, 1 candidate ELISA system was selected to be proposed as the future European Pharmacopoeia standard method for Bet v 1 quantification.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2017 ","pages":"69-87"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmeuropa bio & scientific notes","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
To date, the potency of allergen products in Europe is expressed in manufacturer-specific units relative to a product-specific in-house reference. Consequently, cross-product comparability of allergen products from different manufacturers with respect to strength and efficacy is impossible. The Biological Standardisation Programme (BSP) project BSP090 addresses this issue via the establishment of reference standards in conjunction with ELISA methods for the quantification of major allergens in allergen products. Since the initiation of BSP090, the recombinant major allergen Bet v 1 has been adopted by the European Pharmacopoeia Commission as a Chemical Reference Substance (CRS). In parallel, two sandwich ELISA systems for quantification of Bet v 1 were found suitable in preliminary phases of BSP090 to be validated in a large collaborative study. In this study, the candidate ELISA systems were compared with respect to accuracy, precision and variability. Thirteen participating laboratories tested model samples containing the CRS as well as spiked and unspiked birch pollen extracts. Both in pre-testing and in the collaborative study, the 2 candidate ELISA systems confirmed their suitability to quantify recombinant and native Bet v 1. As no clear-cut decision for one of the ELISA systems could be made based on the results of the collaborative study, a post-study testing was performed. Bet v 1 content of 30 birch pollen allergen products was determined in parallel in both ELISA systems. Consequently, 1 candidate ELISA system was selected to be proposed as the future European Pharmacopoeia standard method for Bet v 1 quantification.
迄今为止,在欧洲,过敏原产品的效力是以制造商特定单位相对于特定产品的内部参考来表示的。因此,不同制造商的过敏原产品在强度和功效方面的跨产品可比性是不可能的。生物标准化计划(BSP)项目BSP090通过建立参考标准,结合ELISA方法对过敏原产品中的主要过敏原进行定量,解决了这一问题。自BSP090启动以来,重组主要过敏原betv1已被欧洲药典委员会采纳为化学参考物质(CRS)。同时,两种夹心ELISA系统被发现适用于BSP090的初步阶段,并将在一项大型合作研究中进行验证。在本研究中,比较了候选ELISA系统的准确性、精密度和可变性。13个参与实验的实验室测试了含有CRS的模型样本,以及带刺和未带刺的桦树花粉提取物。在预测试和合作研究中,这两个候选ELISA系统证实了它们对重组和原生betv1的量化的适用性。由于无法根据合作研究的结果对其中一种ELISA系统做出明确的决定,因此进行了研究后测试。在两个ELISA系统中平行测定了30个桦木花粉过敏原产品的Bet v 1含量。因此,我们选择了1个候选ELISA系统作为未来欧洲药典中betv1定量的标准方法。