{"title":"Effect of Different Types of Toothpaste on the Frictional Resistance Between Orthodontic Stainless Steel Brackets and Wires.","authors":"Tahereh Hosseinzadeh Nik, Tabassom Hooshmand, Homa Farhadifard","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The purpose of this study was to investigate the effect of different types of toothpaste on the frictional resistance between stainless steel brackets and archwires.</p><p><strong>Materials and methods: </strong>Ninety stainless steel orthodontic brackets with stainless steel wires were bonded to bovine teeth and were divided into 6 groups for application of the following toothpastes: Colgate® Total® Advanced Whitening, Colgate® Total® Pro Gum Health, Colgate® Anticavity, Ortho.Kin®, and Sunstar GUM® Ortho toothpastes. No toothpaste was applied in the control group. Each group was brushed by a brushing machine with the use of the designated solution for 4.5 minutes. The frictional force was measured in a universal testing machine with a crosshead speed of 10 mm/minute over a 5-mm archwire. Data were analyzed using one-way analysis of variance (ANOVA) at the 0.05 significance level.</p><p><strong>Results: </strong>The frictional resistance values of Ortho.Kin® and GUM® Ortho toothpastes and the control group were not significantly different (P>0.05). However, there were significant differences between the frictional resistance values of Colgate® Total® Pro Gum Health and Colgate® Anticavity toothpastes with that of the control group (P<0.05). The highest and lowest frictional resistance values were related to Colgate® Total® Pro Gum Health toothpaste and the control group, respectively.</p><p><strong>Conclusions: </strong>Among the evaluated toothpastes, the orthodontic toothpastes did not increase the frictional resistance between the orthodontic stainless steel brackets and wires.</p>","PeriodicalId":30286,"journal":{"name":"Journal of Dentistry of Tehran University of Medical Sciences","volume":" ","pages":"275-281"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5748455/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry of Tehran University of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: The purpose of this study was to investigate the effect of different types of toothpaste on the frictional resistance between stainless steel brackets and archwires.
Materials and methods: Ninety stainless steel orthodontic brackets with stainless steel wires were bonded to bovine teeth and were divided into 6 groups for application of the following toothpastes: Colgate® Total® Advanced Whitening, Colgate® Total® Pro Gum Health, Colgate® Anticavity, Ortho.Kin®, and Sunstar GUM® Ortho toothpastes. No toothpaste was applied in the control group. Each group was brushed by a brushing machine with the use of the designated solution for 4.5 minutes. The frictional force was measured in a universal testing machine with a crosshead speed of 10 mm/minute over a 5-mm archwire. Data were analyzed using one-way analysis of variance (ANOVA) at the 0.05 significance level.
Results: The frictional resistance values of Ortho.Kin® and GUM® Ortho toothpastes and the control group were not significantly different (P>0.05). However, there were significant differences between the frictional resistance values of Colgate® Total® Pro Gum Health and Colgate® Anticavity toothpastes with that of the control group (P<0.05). The highest and lowest frictional resistance values were related to Colgate® Total® Pro Gum Health toothpaste and the control group, respectively.
Conclusions: Among the evaluated toothpastes, the orthodontic toothpastes did not increase the frictional resistance between the orthodontic stainless steel brackets and wires.