{"title":"Effect of Storage Time of a Ceramic Primer on Microshear Bond Strength to Zirconia.","authors":"Amir Ghasemi, Alireza Sadr, Anahita Pourhashemi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study assessed the effect of shelf life of a ceramic primer containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP) monomer on microshear bond strength of zirconia ceramic to composite resin.</p><p><strong>Materials and methods: </strong>Sixty-four sintered zirconia samples (1.5×5×7 mm) were pretreated with Clearfil Ceramic Primer (CCP) at baseline and after one, two and six months of storage at 6°C. Composite cylinders were fabricated using Tygon tubes (1 mm height, 0.7 mm diameter) and placed on treated zirconia blocks, light-cured and subjected to microshear bond strength test. Mode of failure was determined under a stereomicroscope. Fourier-transform infrared spectroscopy (FTIR) was performed at each storage time point. Data were analyzed using one-way ANOVA and Tukey's test.</p><p><strong>Results: </strong>Significant differences were noted in microshear bond strength after six months of storage compared to baseline (P<0.05). Significant differences were noted in FTIR spectra at the four time points (P<0.05).</p><p><strong>Conclusions: </strong>The effectiveness of one-component ceramic primer in bonding to zirconia was significantly affected by the storage of this material in a time-dependent manner. Visible new peaks and changes in FTIR spectra over time indicated alterations in the composition of ceramic primer affecting its shelf life.</p>","PeriodicalId":30286,"journal":{"name":"Journal of Dentistry of Tehran University of Medical Sciences","volume":"15 6","pages":"375-381"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6399461/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry of Tehran University of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: This study assessed the effect of shelf life of a ceramic primer containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP) monomer on microshear bond strength of zirconia ceramic to composite resin.
Materials and methods: Sixty-four sintered zirconia samples (1.5×5×7 mm) were pretreated with Clearfil Ceramic Primer (CCP) at baseline and after one, two and six months of storage at 6°C. Composite cylinders were fabricated using Tygon tubes (1 mm height, 0.7 mm diameter) and placed on treated zirconia blocks, light-cured and subjected to microshear bond strength test. Mode of failure was determined under a stereomicroscope. Fourier-transform infrared spectroscopy (FTIR) was performed at each storage time point. Data were analyzed using one-way ANOVA and Tukey's test.
Results: Significant differences were noted in microshear bond strength after six months of storage compared to baseline (P<0.05). Significant differences were noted in FTIR spectra at the four time points (P<0.05).
Conclusions: The effectiveness of one-component ceramic primer in bonding to zirconia was significantly affected by the storage of this material in a time-dependent manner. Visible new peaks and changes in FTIR spectra over time indicated alterations in the composition of ceramic primer affecting its shelf life.