CFD gas distribution analysis for different continuous-miner scrubber redirection configurations.

Y Zheng, J A Organiscak, L Zhou, T W Beck, J P Rider
{"title":"CFD gas distribution analysis for different continuous-miner scrubber redirection configurations.","authors":"Y Zheng,&nbsp;J A Organiscak,&nbsp;L Zhou,&nbsp;T W Beck,&nbsp;J P Rider","doi":"10.19150/trans.7917","DOIUrl":null,"url":null,"abstract":"<p><p>The U.S. National Institute for Occupational Safety and Health (NIOSH)'s Pittsburgh Mining Research Division (PMRD) recently developed a series of models using computational fluid dynamics (CFD) to study gas distribution around a continuous mining machine with various fan-powered flooded bed scrubber discharge configurations in an exhaust curtain working face. CFD models utilizing species transport model without reactions in FLUENT were constructed to evaluate the redirection of scrubber discharge toward the mining face rather than behind the return curtain. The study illustrates the gas distribution in the slab (second) cut. The following scenarios are considered in this study: 100 percent of the discharge redirected back toward the face on the off-curtain side; 100 percent of the discharge redirected back toward the face, but divided equally to both sides; and 15 percent of the discharge redirected toward the face on the off-curtain side, with 85 percent directed toward the return curtain. These models are compared against a model with a conventional scrubber discharge where air is directed away from the face into the return. The models were validated against experimental data, proving to accurately predict sulfur hexafluoride (SF<sub>6</sub>) gas levels at four gas monitoring locations. This study includes a predictive simulation examining a 45° scrubber angle compared with the 23° angle for the 100 percent redirected, equally divided case. This paper describes the validation of the CFD models based on experimental data of the gas distribution results.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"342 1","pages":"15-21"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5785087/pdf/nihms931860.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19150/trans.7917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The U.S. National Institute for Occupational Safety and Health (NIOSH)'s Pittsburgh Mining Research Division (PMRD) recently developed a series of models using computational fluid dynamics (CFD) to study gas distribution around a continuous mining machine with various fan-powered flooded bed scrubber discharge configurations in an exhaust curtain working face. CFD models utilizing species transport model without reactions in FLUENT were constructed to evaluate the redirection of scrubber discharge toward the mining face rather than behind the return curtain. The study illustrates the gas distribution in the slab (second) cut. The following scenarios are considered in this study: 100 percent of the discharge redirected back toward the face on the off-curtain side; 100 percent of the discharge redirected back toward the face, but divided equally to both sides; and 15 percent of the discharge redirected toward the face on the off-curtain side, with 85 percent directed toward the return curtain. These models are compared against a model with a conventional scrubber discharge where air is directed away from the face into the return. The models were validated against experimental data, proving to accurately predict sulfur hexafluoride (SF6) gas levels at four gas monitoring locations. This study includes a predictive simulation examining a 45° scrubber angle compared with the 23° angle for the 100 percent redirected, equally divided case. This paper describes the validation of the CFD models based on experimental data of the gas distribution results.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同连续矿洗涤器重定向配置的CFD气体分布分析。
美国国家职业安全与健康研究所(NIOSH)匹兹堡采矿研究部(PMRD)最近利用计算流体动力学(CFD)开发了一系列模型,研究了在排气幕工作面中具有各种风机驱动的水床洗涤器排放配置的连续采矿机周围的气体分布。利用FLUENT中不含反应的物质输运模型构建CFD模型,对洗涤器排出物向工作面而非回幕后的重定向进行了评价。研究结果说明了板(二)段瓦斯分布规律。本研究考虑了以下情况:100%的放电重新定向到离帘侧的面部;100%的放电重新流向面部,但两边的放电相等;15%的放电重新定向到窗帘外的一面,85%的放电重新定向到窗帘的背面。这些模型与传统洗涤器排出的模型进行了比较,其中空气从表面直接进入回流。根据实验数据对模型进行了验证,证明该模型能够准确预测四个气体监测点的六氟化硫(SF6)气体水平。该研究包括一个预测模拟,测试了45°的洗涤器角度与23°的100%重定向等分割情况的洗涤器角度。本文介绍了基于气体分布结果的实验数据对CFD模型的验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
TECHNOLOGIES FOR THE NEXT GENERATION CLOSED-CIRCUIT ESCAPE RESPIRATORS. Effect of discontinuity dip direction on hard rock pillar strength. Analysis of extensometer, photogrammetry and laser scanning monitoring techniques for measuring floor heave in an underground limestone mine. Smart monitoring and control system test apparatus. CFD gas distribution analysis for different continuous-miner scrubber redirection configurations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1