M Majewski, P Heisterbach, C Jaquiéry, L Dürselen, A Todorov, I Martin, C H Evans, S A Müller
{"title":"Improved tendon healing using bFGF, BMP-12 and TGFβ1 in a rat model.","authors":"M Majewski, P Heisterbach, C Jaquiéry, L Dürselen, A Todorov, I Martin, C H Evans, S A Müller","doi":"10.22203/eCM.v035a22","DOIUrl":null,"url":null,"abstract":"<p><p>Several growth factors (GFs) are expressed as tendons heal, but it remains unknown whether their combined application enhances the healing process. This matter was addressed by applying a combination of basic fibroblast growth factor (bFGF), bone morphogenetic protein 12 (BMP-12) and transforming growth factor beta 1 (TGFβ1) in a rat Achilles tendon transection model. GFs were applied in one of the three following ways: i) direct application of all three factors at the time of surgery; ii) sequential, tiered percutaneous injection of individual factors immediately after surgery, 48 h and 96 h later; iii) load of all three factors onto a collagen sponge implanted at the time of surgery. After 1, 2, 4 and 8 weeks, healing was assessed based on tendon length and thickness, mechanical strength, stiffness and histology. Best results were achieved when GFs were loaded onto a collagen sponge - with a rapid increase in mechanical strength (load to failure, 71.2 N vs. 7.7 N in controls), consistent tendon length over time (9.9 mm vs. 16.2 mm in controls) and faster tendon remodelling, as measured by histology - followed by tiered injection therapy over 96 h. In conclusion, implantation of a GF-loaded collagen sponge could provide a promising treatment, especially in high-performance athletes and revision cases prone to re-rupture. For conservative treatment, tiered percutaneous GF application could be an option for improving clinical outcome.</p>","PeriodicalId":11849,"journal":{"name":"European cells & materials","volume":"35 ","pages":"318-334"},"PeriodicalIF":3.2000,"publicationDate":"2018-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.22203/eCM.v035a22","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European cells & materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.22203/eCM.v035a22","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CELL & TISSUE ENGINEERING","Score":null,"Total":0}
引用次数: 22
Abstract
Several growth factors (GFs) are expressed as tendons heal, but it remains unknown whether their combined application enhances the healing process. This matter was addressed by applying a combination of basic fibroblast growth factor (bFGF), bone morphogenetic protein 12 (BMP-12) and transforming growth factor beta 1 (TGFβ1) in a rat Achilles tendon transection model. GFs were applied in one of the three following ways: i) direct application of all three factors at the time of surgery; ii) sequential, tiered percutaneous injection of individual factors immediately after surgery, 48 h and 96 h later; iii) load of all three factors onto a collagen sponge implanted at the time of surgery. After 1, 2, 4 and 8 weeks, healing was assessed based on tendon length and thickness, mechanical strength, stiffness and histology. Best results were achieved when GFs were loaded onto a collagen sponge - with a rapid increase in mechanical strength (load to failure, 71.2 N vs. 7.7 N in controls), consistent tendon length over time (9.9 mm vs. 16.2 mm in controls) and faster tendon remodelling, as measured by histology - followed by tiered injection therapy over 96 h. In conclusion, implantation of a GF-loaded collagen sponge could provide a promising treatment, especially in high-performance athletes and revision cases prone to re-rupture. For conservative treatment, tiered percutaneous GF application could be an option for improving clinical outcome.
期刊介绍:
eCM provides an interdisciplinary forum for publication of preclinical research in the musculoskeletal field (Trauma, Maxillofacial (including dental), Spine and Orthopaedics).
The clinical relevance of the work must be briefly mentioned within the abstract, and in more detail in the paper. Poor abstracts which do not concisely cover the paper contents will not be sent for review. Incremental steps in research will not be entertained by eCM journal.Cross-disciplinary papers that go across our scope areas are welcomed.